• 제목/요약/키워드: interrupted

검색결과 705건 처리시간 0.031초

Importance of Nucleotides Adjacent to the Core Region of Diphtheria tox Promoter/Operator

  • Lee, John-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • 제12권4호
    • /
    • pp.622-627
    • /
    • 2002
  • Diphtheria toxin repressor (DtxR) binds to approximately 30 to 35-bp regions containing an interrupted 9-bp inverted repeat within a 19-bp core sequence. The core sequence is fairly conserved and critical for DtxR binding. The flanking regions that are consisted of 5 to 8 more of nucleotides from the core are also required for DtxR binding. The nucleotides in both flanking regions are A-T rich. To examine whether the A-T nucleotides in both flanking regions from the core have significant roles for DtxR binding, a DNA fragment was constructed based on the diphtheria tox promoter/operator, and DNA fragments with substitution of A and T nucleotides In the flanking regions to G and C were also constructed. To assess the effect of these substitutions on binding of DtxR and repressibility by DtxR, $\beta$-galactosidase activity from lacZ fused to the region was assessed. Gel mobility shift of the region by purified DtxR was also examined. The DNA fragments containing the mutations in the flanking regions still exhibited repression and mobility shift with DtxR. The core segment with the mutation is still, therefore, recognized by DtxR. Nonetheless, the results from the assays indicated that the substitution significantly decreased repression of the operator by DtxR in vivo under high-iron condition and decreased binding of DtxR to the operator. These results suggest that A and T nucleotides fur both flanking regions are preferred for the binding of DtxR.

심한 빈혈증상을 동반한 거대한 식도주위허니아 치험 1예 (Belsey Mark V 수술치험) (Giant paraesophageal hiatus hernia associated with severe anemia [Belsy mark V procedure])

  • 이두연
    • Journal of Chest Surgery
    • /
    • 제17권1호
    • /
    • pp.150-156
    • /
    • 1984
  • Paraesophageal hiatus hernia represents a rare hiatal hernia that are treated surgically. The completely asymptomatic paraesophageal hernia often does not reach the clinician or surgeon. But the presence of a symptomatic paraesophageal hernia is sufficient indication for surgery. The paraesophageal hernia may be approached either transthoracically or transabdominally. The general technique is essentially the same, whichever route is used. From either transthoracic or transabdominal approach, following reduction of the viscus and elimination of the sac, the diaphragmatic opening is then closed with interrupted heavy dacron or silk sutures in paraesophageal hiatus hernia. But if the phrenoesophageal membrane often is destroyed when the esophagogastric junction and the distal esophagus have been mobilized, it becomes important to fix the esophagogastric junction below the diaphragm, so that it does not slide through the hiatus and produce a sliding-type hiatus hernia in future. We have experienced one case of paraesophageal hiatus hernia which was accompanied with severe anemia in child. We preferred to approach through left thoracotomy incision and then pushed down the stomach into the abdominal cavity with complete excision of the hernial sac. We employed Belsey Mark V procedure using of Teflon felt pledgets with the mattress sutures against development of sliding-type hiatus hernia in postoperative period. postoperative course has been uneventful and good for about 3 months to this time.

  • PDF

Blunt Trauma 에 의한 기관-식도 파열의 치험 1례 (Rupture of the Trachea and the Esophagus Following Blunt Trauma: A Report of a Case)

  • 정윤채
    • Journal of Chest Surgery
    • /
    • 제8권2호
    • /
    • pp.119-124
    • /
    • 1975
  • This is a case report of the rupture of the trachea and the esophagus following external blunt trauma without any associated injury. A 7 year old male patient was brought to the emergency room. Hanyang University Hospital, on 23 Jul, 1974 while he played under the pile of pingpong table A table was fall down over the patient accidentally. The patient was injured by the table and found lying in unconsciousness on the ground.There was subcutaneous emphysema on his anterior chest and neck. A contusion on the upper part of the sternum was noted. The breathing sound were diminished over the left side of the chest. Ronchi were heard over the right lung field. This patient was suffered from vomiting, dypsnea, and irritable mental state after this accident. On the chest roentgenogram in A-P view, hyperlucency at the mediastinum and parapericardiac area suggested the pneumomediastinum. On the next day, a diagnosis of the tracheal and esophageal rupture was confirmed by the esophagogram with Lipiodol swallowing. A right thoracotomy was performed and ruptured orifice of the trachea and the esophagus were closed with interrupted sutures. Postoperative course was uneventful and primary closure of the rupture of the trachea and the esophagus were succeeded.

  • PDF

관통성 흉부 자상에 의한 심실중격 결손증: 증례보고 (Ventricular Septal Defect by Penetrating Chest Trauma - Report of One Case -)

  • 김문환;이철주
    • Journal of Chest Surgery
    • /
    • 제25권4호
    • /
    • pp.429-434
    • /
    • 1992
  • We experienced a rare case of traumatic ventricular septal defect by penetrating stab injury The patient was 26-year-old women who got stab wound at the left anterior third intercostal space and left sternal border with a knife. seven hours after admission, the patient was undertaken an emergency thoracotomy due to hypovolemic shock caused by massive bleeding from transected left internal mammary artery, vein, and right ventricular outflow tract. On postoperative second day, the patient was suffered from moderate dyspnea, and arterial blood gas analysis and chest X-ray revealed hypoxemia and pulmonary edema. Right heart cardiac catheterization with Swan-Ganz Cathater showed oxygen step-up between right atrium and main pulmonary artery and a 1.6:1 ratio of pulmonary to systemic blood flow. At operation, harsh systolic thrill was palpable along right ventricular outflow tract. Through small vertical right ventriculotomy, the linear ventricular septal laceration on infundibular septum was noticed, and its size was 1.5cm with sharp margin This defeat was repaired by three interrupted matress sutures using Prolene 4-O with pledget. Her postoperative course was uneventful, and she discharged with good physical condition.

  • PDF

Transcriptional Induction of a Carbon Starvation Gene during Other Starvation and Stress Challenges in Pseudomonas putida MK1: A Role of a Carbon Starvation Gene in General Starvation and Stress Responses

  • Chitra, Subramanian;Lee, Ho-Sa;Kim, Youngjun
    • Journal of Microbiology
    • /
    • 제37권3호
    • /
    • pp.141-147
    • /
    • 1999
  • Thirteen transcriptionally-fused carbon starvation mutants, derived from Pseudomonas putida ATCC 12633, were analyzed for their survivability and transcriptional induction profiles upon carbon starvation. One of these mutants, MK114, which exhibited the lowest survivability and the highest induction rate, was selected and further examined under different starvation (nitrogen and phosphate) and stress (osmolarity, H2O2, salts, alcohol, and heat) conditions. Under all tested conditions MK114 induced ${\beta}$-galactosidase activity, implying that the interrupted gene (cst114) is a general starvation and stress response gene. The rate of induction ranged from 2.6-fold for phosphate starvation to 3.7-fold for osmotic shock. The mini-Tn5 flanking DNA was cloned from the chromosome of MK114. The cloned DNA fragment exhibited carbon starvation activity, indicating that this fragment contains a carbon starvation-related promoter region. This region was partially sequenced. Possible physiological roles of Cst114 in a carbon sensing mechanism and in other stress responses are also discussed.

  • PDF

미취학 자녀를 둔 도시 맞벌이 부부의 여가시간에 관한 연구 (The Analysis of Leisure Time Use of Urban Dual-earner Couples with Preschool Children)

  • 한영선;윤소영
    • 대한가정학회지
    • /
    • 제47권2호
    • /
    • pp.81-95
    • /
    • 2009
  • The purpose of this study is to examine gender equity in the quantity and flow experience of leisure time of urban dual-earner couples having preschool children. The quantity of leisure time is measured by primary activity and the flow experience of leisure time is measured by primary and secondary activities. The data collected by Korean National Statistical Office in 2004 is used. The sample for this study consists of 255 couples, and the statistical methods are frequency, percentage, paired t-test, and one-way ANOVA. The following is a summary of the major findings. The first, the pattern of the leisure time was different between husbands and wives. The quantity of leisure time of husbands was longer than that of wives. The husbands spent more time to perform social activities, media contact, sports and outdoor activities, while women did more in religious activities. The second, husband's leisure flow experience was higher than that of wives. The pure leisure time of wives was shorter than that of husbands and wives experienced more contaminated leisure time by a secondary activity. In other words, wives's leisure is more likely to be interrupted, to involve episodes of shorter duration, and to be associated with personal care and unpaid work.

PTFE 노즐로부터 발생하는 용삭가스를 고려한 스위칭 아크 해석 (Numerical Analysis of Switching Arcs with the Ablation of PTFE Nozzles)

  • 이원호;김홍규;이종철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1536-1537
    • /
    • 2011
  • The high-voltage circuit breaker plays an important role in the electrical system because there has been a need for suitable switching devices capable of initiating and interrupting the flow of the electric fault current. It continues as the contacts recede from each other and as the newly created gap is bridged by a plasma. The arc plasma happens inside the insulation nozzle of SF6 self-blast interrupter which is newly developed as the next-generation switching principle. The ablation of PTFE nozzle is caused by this high temperature medium, the PTFE vapor from the nozzle surfaces flows toward the outlets and the pressure chamber. The vapor makes the pressure of the chamber increased by heat and mass transfer from the arcing zone. Because the rate of ablation depends on the magnitude of applied current, it decreases when the current goes to zero. The compressed gas inside the chamber flows reversely toward the arc plasma during this moment. According to this principle, the arc can be cooled down and the fault current can be interrupted successfully. In this study, we calculate arc plasmas and thermal-flow characteristics caused by fault current interruption inside a SF6 self-blast interrupter, and to investigate the effect of PTFE ablation on the whole arcing history.

  • PDF

부분심내막상 결손증의 교정수술치험 1 (Surgical correction of partial endocardial cushion defect: one case report)

  • 기노석
    • Journal of Chest Surgery
    • /
    • 제17권2호
    • /
    • pp.244-249
    • /
    • 1984
  • Surgical treatment of partial endocardial cushion defect was accomplished in Feb. 1984 in this department. The 5 year old male patient had history of frequent upper respiratory tract infection and since his age of 3 years dyspnea on exertion and palpitation were noted but there were no cyanosis and clubbing. A thrill was palpable on the apex and grade IV/IV harsh systolic ejection murmur and diastolic murmur was audible on it. Liver was palpable about 3 finger breadths and no ascites. Chest X-ray revealed increased pulmonary vascularity, moderate cardiomegaly [C-T ratio; 0.69], and enlarged left atrium. EKG showed first degree heart block, RVH, LVH, and LAD. Echocardiogram showed paradoxical ventricular septal movement and abnormal diastolic movement of the anterior leaflet of mitral valve. Right heart catheterization resulted left to right shunt [Qp:Qs:2.1:1 ] and moderate pulmonary hypertension [60/40 mmHg]. Left ventriculogram showed mitral regurgitation [Grade III/IV] and filling of left atrium and right atrium nearly same time. Operative findings were: 1.Primum type atrial septal defect [3x2 cm] 2.Cleft on the anterior leaflet of mitral valve. 3.No interventricular communication and cleft of tricuspid valve leaflet. The mitral cleft was repaired with 4 interrupted sutures. The primum type atrial septal defect was closed with Dacron patch intermittently at endocardial cushion and continuously remainder. The post operative course was uneventful and discharged on 22nd postoperative day in good general conditions.

  • PDF

CBN 연삭숫돌의 초음파 인프로세스 드레싱 기법 (A Study on the Ultrasonic In-Process Dressing Method of CBN Grinding Wheel)

  • 이석우;정해도;최헌종
    • 한국정밀공학회지
    • /
    • 제17권2호
    • /
    • pp.43-50
    • /
    • 2000
  • A CBN wheel was used for the highly efficient and precision grinding of the mold material(STD11). The grinding form accuracy by a CBN wheel is very excellent due to its low wheel wear, but grinding fragments resemble fine powders rather chips. A fine powders by this fragmentation can easily get attached to the wheel surface and therefore causing a loading. In order to prevent this fragmentation phenomena, the alumina stick is use to processing. Because the dressing with alumina stick should be interrupted for a processing, the automation of the processing and high productivity was very difficult. The investigation on the effect of Ultrasonic In-Process Dressing(ULID) on the grinding characteristics focuses in this Paper. This ULID method is that ultrasonic vibration in my Position of wheel is used to remove impurities on the wheel surface. Finally, the rate of surface roughness change in grinding by the ULID method was less than grinding without ultrasonic vibration. Loading phenomena by the ULID method were more prevented than grinding without ultrasonic vibration.

  • PDF

신속개방형 콘크리트 도로포장재의 설계를 위한 평가 연구(3) (A Study and Evaluation of Super High Early Strength Concrete as Pavement Overlay Materials for Early Traffic Opening(3))

  • 임채용;엄태선;유재상;이종열;엄주용;조윤호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.607-612
    • /
    • 2002
  • In road pavements, it is known that cement concrete pavement has superior durability, safety compared. But in repairing pavement, cement concrete pavement is not usually applied because of the length of time while the road is interrupted when using Ordinary and Rapid-hardening Portland Cement. And Super High Early Strength Cement and Ultra Super High Early Strength Cement are not favorable for ready mixed concrete because of rapid setting time, high slump loss and other restrictions. We developed special cement developing 1 day strength of over 30.0N/mm$^2$ to open the road within 1 day and workable time is maintained over 1 hour so that it can be used as ready mixed concrete. We performed experimental overlay construction with the cement and evaluated the mechanical property and the durability. At curing temperature of 8-l8$^{\circ}C$,the flexural strength was 6.4N/mm$^2$at 1 day, so that the road can be open to traffic within 1 day. In durability test, the hardened concrete showed higher durability than Portland cement concrete.

  • PDF