• 제목/요약/키워드: interphase transformer

검색결과 8건 처리시간 0.023초

자석-부하 전원장치를 위한 위상제어 정류기와 PWM 컨버터를 사용한 복합구조 시스템의 전력회로 개선 (A Power Circuit Improvement of the Hybrid System Using Phase Controlled Rectifier and PWM Converter for Magnet Load Power Supply)

  • 강민구;손진근;전희종
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.231-235
    • /
    • 2008
  • Thyristor rectifiers are still the preferred choice for large magnet power supplies. However, large harmonic voltages, resulting in large current ripple, and slow dynamic response are major drawbacks of these converters. Joos presented a topology and a control technique for a hybrid large-power high-precision magnet power supply in 1996. The system consists of a phase controlled rectifier (PCR) connected in series with a high-frequency PWM converter. This paper improves the power circuit of the PWM converter using interphase transformer. Simulation result proves effect of the proposed system.

대전류 코일 전원 공급장치를 위한 12펄스 듀얼 컨버터의 전류제어 (Current Control of 12-pulse Dual Converter for High Current Coil Power Supply)

  • 송승호
    • 전력전자학회논문지
    • /
    • 제7권4호
    • /
    • pp.332-338
    • /
    • 2002
  • 토카막 장치의 초전도 코일에 사용되는 전원 공급장치는 초대형급(20kA) 직류 전원 공급기로서 빠른 전류제어 응답성과 매우 작은 정상상태 리플이 필수적이다. 특히 역전류 공급이 가능한 회생형 컨버터의 운전중 전류 방향이 바뀌는 순간에도 전류기준값을 잘 추종하는 것이 중요하다. 이러한 조건들을 만족시키기 위하여 입력측에 2중 출력($\Delta$, Y)를 갖는 변압기와 출력단에 상간변압기(interphase transformer, IPT)를 이용한 12펄스 싸이리스터 듀얼 컨버터를 설계, 제작하였다. 각 컨버터에서 출력되는 전류의 합이 부하전류 지령치를 따르도록 제어하는 동시에 차 전류의 평균값이 영이 되도록 함으로써 각 컨버터의 부하 분담율을 일정하게 하여 상간 변압기의 포화를 방지한다. 대전류 코일 전류 공급장치의 양방향 전류 제어 성능을 높이기 위하여 위상각 검출 및 게이팅 지연각 구현을 디지털화하고 컨버터 전류방향 정역절환시 초기 응답특성을 개선하는 방법을 제안하였다. 또한 시뮬레이션과 실부하 전류실험을 통해 제안된 제어기의 동작성능을 확인하였다.

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.

3상 비대칭 정류회로의 PAM 방식을 이용한 고주파 저감법 (Reducing Harmonics of 3-Phase Asymmctic Recnher Current using a PAM mcthod)

  • 오훈;윤양웅;박현철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1995년도 추계학술발표회논문집
    • /
    • pp.105-109
    • /
    • 1995
  • In this paper, we persents a new PAM method without the input transformer for reducing harmonics in input AC line currents of converter. This system can reduce the harmonics like conventional 12-pulse converter. the dual bridge circuits are controlled with the shifted firing angle and connected 2 tap interphase reactor. the input current using 2 tap changing on interphase reactor is controlled with the different two values in order to make the input current waveform 12 pulses. The chracteristics of this system were confirmed through the computer simulation and the experiments.

  • PDF

A New 12-Pulse Diode Rectifier System With Low kVA Components For Clean Power Utility Interface

  • 이방섭
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.423-432
    • /
    • 1999
  • This paper proposes a 12­pulse diode rectifier system with low kVA components suitable for powering switch mode power supplies or ac/dc converter applications. The proposed 12-pulse system employs a polyphase transformer, a zero sequence blocking transformer (ZSBT) in the dc link, and an interphase transformer. Results produce near equal leakage inductance in series with each diode rectifier bridge ensuring equal current sharing and performance improvements, The utility input currents and the voltage across the ZSBT are analyzed the kVA rating of each component in the proposed system is computed. The 5th , 7th , 17th and 19th harmonics are eliminated in the input line currents resulting in clean input power. The dc link voltage magnitude generated by the proposed rectifier system is nearly identical to a conventional to a conventional 6-pulse system. The proposed system is suitable to retrofit applications as well as in new PWM drive systems. Simulation and experimental results from a 208V , 10kVA system are shown.

  • PDF

Reduced Rating T-Connected Autotransformer Based Thirty-Pulse AC-DC Converter for Vector Controlled Induction Motor Drives

  • Singh Bhim;Bhuvaneswari G.;Garg Vipin
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.214-225
    • /
    • 2006
  • The design and performance analysis of a reduced rating autotransformer based thirty-pulse AC-DC converter is carried out for feeding a vector controlled induction motor drive (VCIMD). The configuration of the proposed autotransformer consists of only two single phase transformers, with their windings connected in a T-shape, resulting in simplicity in design, manufacturing and in a reduction in magnetics rating. The design procedure of the autotransformer along with the newly designed interphase transformer is presented. The proposed configuration has flexibility in varying the transformer output voltage ratios as required. The design of the autotransformer can be modified for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The proposed thirty-pulse AC-DC converter is capable of suppressing less than $29^{th}$ harmonics in the supply current. The power factor is also improved to near unity in the wide operating range of the drive. A comparison of different power quality indices at AC mains and DC bus is demonstrated in a conventional 6-pulse AC-DC converter and the proposed AC-DC converter feeding a VCIMD. A laboratory prototype of the proposed autotransformer based 30-pulse AC-DC converter was developed with test results validating the proposed design and system.

이중접속방식의 멀티스텝 인버터를 이용한 대용량 STATCOM의 개발 (Development of a Large Scale STATCOM Using Double-Connected Multistep Inverter)

  • 김태훈;배영상;최세완;이왕하
    • 전력전자학회논문지
    • /
    • 제9권1호
    • /
    • pp.36-41
    • /
    • 2004
  • 본 논문에서는 이중접속 방식의 멀티스텝 인버터를 이용한 대용량 STATCOM에 관하여 동작원리 및 제어 방식을 기술하기로 한다. 기존의 12-스텝 인버터에 상간 변압기 및 간단한 보조회로를 이용하여 출력전압의 파형을 36-스텝으로 개선하였다. 이러한 방식의 인버터는 특히 10Mvar∼30Mvar급 전후의 STATCOM에 적용하면 경제적이다. 2KVA급 STATCOM 시작품의 실험결과로부터 제안한 방식의 타당성을 입증하였다.

새로운 능동형 고역률 다이오드 정류기시스템 (A New High Power Factor Correction Diode Rectifier System)

  • 김현정;최세완;원충연;김규식
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.543-550
    • /
    • 2003
  • 본 논문에서는 2대의 다이오드 정류기에 부스트 컨버터를 이용하여 전류의 파형을 능동적으로 만들어 정현파의 입력전류를 얻는 새로운 방식의 고조파 저감방식을 제안한다. 제안한 방식으로 고역률의 전원 품질을 얻을 수 있으며 입력측의 변동에 대한 출력전압의 조정도 가능하다. 또한 저감된 용량을 갖는 3상 오토트랜스포머의 사용으로 기존의 $\Delta$-Y 변압기에 비해 KVA정격이 75% 절감되며 상간변압기도 필요 없다. 본 방식을 소형화와 고품질의 전원이 요구되는 통신용 정류기등에 적용하면 효과적이다. 제안한 방식의 동작원리, 제어 및 설계방법을 기술하고 1.5KW급 시작품으로부터의 실험결과를 제시한다.