• Title/Summary/Keyword: interphase transformer

Search Result 8, Processing Time 0.023 seconds

A Power Circuit Improvement of the Hybrid System Using Phase Controlled Rectifier and PWM Converter for Magnet Load Power Supply (자석-부하 전원장치를 위한 위상제어 정류기와 PWM 컨버터를 사용한 복합구조 시스템의 전력회로 개선)

  • Kang, Min-Gu;Shon, Jin-Geun;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.231-235
    • /
    • 2008
  • Thyristor rectifiers are still the preferred choice for large magnet power supplies. However, large harmonic voltages, resulting in large current ripple, and slow dynamic response are major drawbacks of these converters. Joos presented a topology and a control technique for a hybrid large-power high-precision magnet power supply in 1996. The system consists of a phase controlled rectifier (PCR) connected in series with a high-frequency PWM converter. This paper improves the power circuit of the PWM converter using interphase transformer. Simulation result proves effect of the proposed system.

Current Control of 12-pulse Dual Converter for High Current Coil Power Supply (대전류 코일 전원 공급장치를 위한 12펄스 듀얼 컨버터의 전류제어)

  • 송승호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.332-338
    • /
    • 2002
  • High current coil power supply for superconductivity coil of tokamak requires fast dynamics performance of di/dt and smooth change over of current direction. To meet the specification high performance DSP-based controller Is designed for 12-pulse thyristor dual converter with interphase transformer(IPT). Not only the total current of Y and $\Delta$ converter units but also the difference for those should be regulated fast and accurately. Proportional and integral controller is designed for current difference control and the controller output is compensated to $\Delta$ converter. The source voltage phase angle detection and gate pulse generation algorithm are implemented in software for higher reliability of current control. The current error Is reduced by selection of appropriate initial gating angle during the transient of change over of current direction between thyristor converters.

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.

Reducing Harmonics of 3-Phase Asymmctic Recnher Current using a PAM mcthod (3상 비대칭 정류회로의 PAM 방식을 이용한 고주파 저감법)

  • Oh, Hoon;Yoon, Yang-Woong;Park, Hyun-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.105-109
    • /
    • 1995
  • In this paper, we persents a new PAM method without the input transformer for reducing harmonics in input AC line currents of converter. This system can reduce the harmonics like conventional 12-pulse converter. the dual bridge circuits are controlled with the shifted firing angle and connected 2 tap interphase reactor. the input current using 2 tap changing on interphase reactor is controlled with the different two values in order to make the input current waveform 12 pulses. The chracteristics of this system were confirmed through the computer simulation and the experiments.

  • PDF

A New 12-Pulse Diode Rectifier System With Low kVA Components For Clean Power Utility Interface

  • ;Prasad N.Enjeti
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.423-432
    • /
    • 1999
  • This paper proposes a 12­pulse diode rectifier system with low kVA components suitable for powering switch mode power supplies or ac/dc converter applications. The proposed 12-pulse system employs a polyphase transformer, a zero sequence blocking transformer (ZSBT) in the dc link, and an interphase transformer. Results produce near equal leakage inductance in series with each diode rectifier bridge ensuring equal current sharing and performance improvements, The utility input currents and the voltage across the ZSBT are analyzed the kVA rating of each component in the proposed system is computed. The 5th , 7th , 17th and 19th harmonics are eliminated in the input line currents resulting in clean input power. The dc link voltage magnitude generated by the proposed rectifier system is nearly identical to a conventional to a conventional 6-pulse system. The proposed system is suitable to retrofit applications as well as in new PWM drive systems. Simulation and experimental results from a 208V , 10kVA system are shown.

  • PDF

Reduced Rating T-Connected Autotransformer Based Thirty-Pulse AC-DC Converter for Vector Controlled Induction Motor Drives

  • Singh Bhim;Bhuvaneswari G.;Garg Vipin
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.214-225
    • /
    • 2006
  • The design and performance analysis of a reduced rating autotransformer based thirty-pulse AC-DC converter is carried out for feeding a vector controlled induction motor drive (VCIMD). The configuration of the proposed autotransformer consists of only two single phase transformers, with their windings connected in a T-shape, resulting in simplicity in design, manufacturing and in a reduction in magnetics rating. The design procedure of the autotransformer along with the newly designed interphase transformer is presented. The proposed configuration has flexibility in varying the transformer output voltage ratios as required. The design of the autotransformer can be modified for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The proposed thirty-pulse AC-DC converter is capable of suppressing less than $29^{th}$ harmonics in the supply current. The power factor is also improved to near unity in the wide operating range of the drive. A comparison of different power quality indices at AC mains and DC bus is demonstrated in a conventional 6-pulse AC-DC converter and the proposed AC-DC converter feeding a VCIMD. A laboratory prototype of the proposed autotransformer based 30-pulse AC-DC converter was developed with test results validating the proposed design and system.

Development of a Large Scale STATCOM Using Double-Connected Multistep Inverter (이중접속방식의 멀티스텝 인버터를 이용한 대용량 STATCOM의 개발)

  • 김태훈;배영상;최세완;이왕하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.36-41
    • /
    • 2004
  • In this paper a large scale STATCOM using double-connected multi-step inverter is proposed and operating principle along with control method is detailed. A simple auxiliary circuit including an interphase transformer is employed to improve output voltage waveform of 12-step into 36-step. The proposed scheme could be a cost effective approach in high power applications such as 10MVar to 30MVar STATCOM. Experimental results from a 2KVA laboratory prototype show validity of the proposed method.

A New High Power Factor Correction Diode Rectifier System (새로운 능동형 고역률 다이오드 정류기시스템)

  • 김현정;최세완;원충연;김규식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.543-550
    • /
    • 2003
  • Thin paper proposes a new three-phase rectifier that actively shapes the input current sinusoidal by means of two rectifier bridges, each followed by a dc-dc boost converter. The proposed approach draws sinusoidal input current at unity power factor and has output voltage regulation capability The size and weight of magnetic material Is reduced by Incorporating a low KVA three-phase autotransformer and by directly connecting the dc outputs each other without using low frequency interphase transformer(IPT). The operation principle is described along with simple control method, and experimental results on a 1.5KW prototype are provided.