• Title/Summary/Keyword: interobserver reliability

Search Result 38, Processing Time 0.021 seconds

Comparision of two cephalometric superimposition methods - Nasion-sella line method and Anterior cranial base method (두가지 두부 방사선 사진 중첩 방법의 비교 - Nasion-Sella line 중첩과 Anterior cranial base 중첩)

  • Kyung, Seung-Hyun;Moon, Yon-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.633-641
    • /
    • 1997
  • Spatial change of craniofacial structures from growth or orthopedic force is usually evaluated by cephalometric superimpositions at different points in time.As the evaluation cu be changed according to cephalometric superimposition method,selettion for correct superimposition method is very important.Double registration of nineteen pairs of female lateral head films,their growth period is average 3.7 years and age is overage 10.7 years,were performed by two observers.Comparisions was made between two methods and the results revealed the following, 1. NS line and ACB superimpositions ate not markedly different in reliability due to almost same registration error of them. 2. The investigation was undertaken to examine interobserver difference.In NS line method, there is no significance in all measurements. In ACB method,significant difference was revealed in 4 measurements of 7 measurements was 3. In the investigation of intermethod difference, there is no significance between NS line and ACB superimpositions

  • PDF

Cephalometric landmark variability among orthodontists and dentomaxillofacial radiologists: a comparative study

  • Durao, Ana Paula Reis;Morosolli, Aline;Pittayapat, Pisha;Bolstad, Napat;Ferreira, Afonso P.;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.213-220
    • /
    • 2015
  • Purpose: The aim this study was to compare the accuracy of orthodontists and dentomaxillofacial radiologists in identifying 17 commonly used cephalometric landmarks, and to determine the extent of variability associated with each of those landmarks. Materials and Methods: Twenty digital lateral cephalometric radiographs were evaluated by two groups of dental specialists, and 17 cephalometric landmarks were identified. The x and y coordinates of each landmark were recorded. The mean value for each landmark was considered the best estimate and used as the standard. Variation in measurements of the distance between landmarks and measurements of the angles associated with certain landmarks was also assessed by a subset of two observers, and intraobserver and interobserver agreement were evaluated. Results: Intraclass correlation coefficients were excellent for intraobserver agreement, but only good for interobserver agreement. The least reliable landmark for orthodontists was the gnathion (Gn) point (standard deviation [SD], 5.92 mm), while the orbitale (Or) was the least reliable landmark (SD, 4.41 mm) for dentomaxillofacial radiologists. Furthermore, the condylion (Co)-Gn plane was the least consistent (SD, 4.43 mm). Conclusion: We established that some landmarks were not as reproducible as others, both horizontally and vertically. The most consistently identified landmark in both groups was the lower incisor border, while the least reliable points were Co, Gn, Or, and the anterior nasal spine. Overall, a lower level of reproducibility in the identification of cephalometric landmarks was observed among orthodontists.

Volumetric CT Texture Analysis of Intrahepatic Mass-Forming Cholangiocarcinoma for the Prediction of Postoperative Outcomes: Fully Automatic Tumor Segmentation Versus Semi-Automatic Segmentation

  • Sungeun Park;Jeong Min Lee;Junghoan Park;Jihyuk Lee;Jae Seok Bae;Jae Hyun Kim;Ijin Joo
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1797-1808
    • /
    • 2021
  • Objective: To determine whether volumetric CT texture analysis (CTTA) using fully automatic tumor segmentation can help predict recurrence-free survival (RFS) in patients with intrahepatic mass-forming cholangiocarcinomas (IMCCs) after surgical resection. Materials and Methods: This retrospective study analyzed the preoperative CT scans of 89 patients with IMCCs (64 male; 25 female; mean age, 62.1 years; range, 38-78 years) who underwent surgical resection between January 2005 and December 2016. Volumetric CTTA of IMCCs was performed in late arterial phase images using both fully automatic and semi-automatic liver tumor segmentation techniques. The time spent on segmentation and texture analysis was compared, and the first-order and second-order texture parameters and shape features were extracted. The reliability of CTTA parameters between the techniques was evaluated using intraclass correlation coefficients (ICCs). Intra- and interobserver reproducibility of volumetric CTTAs were also obtained using ICCs. Cox proportional hazard regression were used to predict RFS using CTTA parameters and clinicopathological parameters. Results: The time spent on fully automatic tumor segmentation and CTTA was significantly shorter than that for semi-automatic segmentation: mean ± standard deviation of 1 minutes 37 seconds ± 50 seconds vs. 10 minutes 48 seconds ± 13 minutes 44 seconds (p < 0.001). ICCs of the texture features between the two techniques ranged from 0.215 to 0.980. ICCs for the intraobserver and interobserver reproducibility using fully automatic segmentation were 0.601-0.997 and 0.177-0.984, respectively. Multivariable analysis identified lower first-order mean (hazard ratio [HR], 0.982; p = 0.010), larger pathologic tumor size (HR, 1.171; p < 0.001), and positive lymph node involvement (HR, 2.193; p = 0.014) as significant parameters for shorter RFS using fully automatic segmentation. Conclusion: Volumetric CTTA parameters obtained using fully automatic segmentation could be utilized as prognostic markers in patients with IMCC, with comparable reproducibility in significantly less time compared with semi-automatic segmentation.

A Review of Studies of Tongue Deviations in Korean Stroke Patients (국내 중풍 환자의 설진에 관한 연구 고찰)

  • Park, Young-hwa;Lim, Bo-ra;Cho, Jun-ho;Won, Jeong-yoon;Kwon, Do-ick
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.2
    • /
    • pp.152-163
    • /
    • 2017
  • Objectives: The aim of this review was to compare the findings of 14 studies of tongue diagnosis in Korean stroke patients. Methods: The purpose, subjects, observation methods, statistical methods, classification of tongue diagnosis, significance, and limitations were analyzed and compared. Results: In Korean stroke patients, tongue diagnosis is significant in pattern identifications, prognosis evaluation, degree of neurological deficit, past history, blood tests, and pulse diagnosis. Interobserver reliability of tongue diagnosis is relatively high.

The New Radiographic Evaluation of Hindfoot Alignment (후족부 정렬의 새로운 방사선학적 평가 방법)

  • Han, Woo-Yeon;Lee, Ho-Seong;Kim, Won-Kyeong;Ahn, Ji-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.3
    • /
    • pp.169-174
    • /
    • 2012
  • Purpose: There are various methods proposed for the evaluation of the hindfoot alignment. However, due to structural calcaneus variances between patients, it is hard to assess this alignment definitively. Thus, this study proposes a new method for evaluating of the hindfoot alignment and its comparisons to the existing current methods. Materials and Methods: This study includes simple weight bearing hindfoot coronal view radiographs of 120 patients, taken between the time period of March 2008 to November 2009. Among the 120 patients, there was a 1:1 ratio of male to female with an average age of 40. The newly proposed method for evaluating this alignment is to draw a moment arm from the point where the sustentaculum tali meets the medial calcaneus border to the most prominent aspect of the lateral process of the calcaneal tuberosity. The angle produced via the intersection of this moment arm to the mid-longitudinal axis of the tibia is found and used to evaluate the hindfoot alignment. The inter and intra-observer reliability was evaluated using the coefficient of intraclass correlation. This study also investigates the comparisons between the newly proposed method to the traditionally used Saltzman et al hindfoot alignment evaluating technique. Results: The newly proposed method has higher inter and intra-observer reliability than the existing traditional Saltzman et al technique. Conclusion: This new method is recommended over the traditionally used Saltzman et al technique as it has a stronger confidence level and is appropriate for assessing hindfoot alignment in simple radiographs.

Radiographic Measurement of Ankle Lateral Stability in Normal Korean Adults (정상 한국 성인에서 발목관절 외측 안정성의 방사선학적 계측)

  • Shon, Hyun-Chul;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Park, Kyoung-Jin;Cho, Byung-Ki;Park, Ji-Kang;Hong, Kyung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose: Anterior drawer and varus stress test are commonly used for radiologic evaluation of chronic lateral ankle instability. However, there are controversies regarding the method of measurement and the normal value. This study was performed to investigate radiologic normal values in normal Korean adults and to analyze differences by age and gender. Materials and Methods: Sixty Korean adults were recruited and divided in three groups (20 in their twenties, 20 in their thirties, 20 in their forties). There were 10 males and 10 females in each group. The selection criteria were no history of ankle injury and no evidence of instability on physical examination. Radiologic measurement of varus talar tilt and anterior talar translation were performed through anterior and varus stress radiographs using Telos device (150N force). The measurement was repeated twice by three researchers, and intraobserver reproducibility and interobserver reliability were analyzed. The average talar tilt and anterior talar translation were obtained. Results: Talar tilt and anterior talar translation on ankle stress radiographs had good intraobserver reproducibility and interobserver reliability. Talar tilt was average $3.7^{\circ}$ and $5.1^{\circ}$ in male and female of twenties of age, $3.9^{\circ}$ and $4.8^{\circ}$ in their thirties, $3.4^{\circ}$ and $4.5^{\circ}$ in their forties. Anterior talar translation was average 3.5 mm and 4.2 mm in their twenties, 4.1 mm and 3.8 mm in their thirties, 3.6 mm and 4.1 mm in their forties. There was no significant difference in talar tilt and anterior talar translation by age. However, there was significant difference in talar tilt by gender. Conclusion: Normal range of talar tilt angle in Korean adults was below $8.3^{\circ}$, and normal range of anterior talar translation was below 7.6 mm. It seems to be able to serve as a good reference for radiologic evaluation and for treatment of chronic lateral ankle instability.

Pediatric Dehydration Assessment at Triage: Prospective Study on Refilling Time

  • Caruggi, Samuele;Rossi, Martina;De Giacomo, Costantino;Luini, Chiara;Ruggiero, Nicola;Salvatoni, Alessandro;Salvatore, Silvia
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.4
    • /
    • pp.278-288
    • /
    • 2018
  • Purpose: Dehydration is a paediatric medical emergency but there is no single standard parameter to evaluate it at the emergency department. Our aim was to evaluate the reliability and validity of capillary refilling time as a triage parameter to assess dehydration in children. Methods: This was a prospective pilot cohort study of children who presented to two paediatric emergency departments in Italy, with symptoms of dehydration. Reliability was assessed by comparing the triage nurse's measurements with those obtained by the physician. Validity was demonstrated by using 6 parameters suggestive of dehydration. Comparison between refilling time (RT) and a validated Clinical Dehydration Score (CDS) was also considered. The scale's discriminative ability was evaluated for the outcome of starting intravenous rehydration therapy by using a receiver operating characteristic (ROC) curve. Results: Participants were 242 children. All nurses found easy to elicit the RT after being trained. Interobserver reliability was fair, with a Cohen's kappa of 0.56 (95% confidence interval [CI], 0.41 to 0.70). There was a significant correlation between RT and weight loss percentage (r-squared=-0.27; 95% CI, -0.47 to -0.04). The scale's discriminative ability yielded an area under the ROC curve (AUC) of 0.65 (95% CI, 0.57 to 0.73). We found a similarity between RT AUC and CDS-scale AUC matching the two ROC curves. Conclusion: The study showed that RT represents a fast and handy tool to recognize dehydrated children who need a prompt rehydration and may be introduced in the triage line-up.

The Marital Interaction Coding System-Global(MICS-G): A Validation Study (포괄적 부부상호작용 코딩시스템(MICS-G) 국내 타당화 연구)

  • Park, Woochul
    • Human Ecology Research
    • /
    • v.57 no.1
    • /
    • pp.109-125
    • /
    • 2019
  • Few studies have utilized observational methods in the field of couple research even though using self-report questionnaires is prone to the subjective biases of the reporter. This study validates the Marital Interaction Coding System-Global (MICS-G), a global version of the well-established microanalytic observational coding system, Marital Interaction Coding System (MICS). Participants in the study consisted of 30 married couples with varied levels of marital adjustment who visited one of the Healthy Family and Multicultural Family Support Centers in Seoul, either for couple therapy or the "Marriage Checkup"program. Ten-minute problem-solving discussions were rated by two undergraduate student raters who were trained for 10 hours. Interobserver agreement based on percentage agreement and intraclass correlation coefficients showed a high level of agreement between raters in establishing interrater reliability. Convergent validity was established by: correlations among marital adjustment, psychological aggression, mental health, and MICS-G categories of conflicts, validation, invalidation, facilitation, and withdrawal. MICS-G categories also were successful in discriminating between distressed and nondistressed couples, which provides evidence of discriminant validity for MICS-G. This study showed that MICS-G is a promising method for researchers to observe couple interactions in a more cost-effective way. Methodological issues and practical applications are also discussed.

Comparison of Angle Measurements on Hallux Valgus with Two Different Methods Using Digital Images (디지털 영상을 이용한 무지 외반증 변형각 측정에서 서로 다른 두 계측 방법의 비교)

  • Sung, Il-Hoon;Kim, Ki Chun;Sung, Chang-Ho;Seo, Woo-Young;Lee, Doo-Yeon;Cho, Young A
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.1
    • /
    • pp.40-44
    • /
    • 2013
  • Purpose: To study inter- and intra-observer reliabilities of computerized measurements of the angular parameters of hallux valgus deformity, using two different kinds of software tools for angle measurement on the digital radiography. Materials and Methods: On 35 digital radiographies of standing foot anteroposterior view of hallux valgus, two observers (A, B) independently measured hallux valgus angle (HVA) and 1-2 intermetatarsal angle ($IMA_{1-2}$) twice, using two methods. In method I, an angle was determined from duplicated lines to longitudinal axes made for bisecting line on the target bones with software tool. In method II, an angle was calculated automatically and directly from bisecting lines (longitudinal axes) made on the target bones. We compared two methods using paired t-test to determine significance of differences. Inter- and intraobserver reliabilities were evaluated using the intraclass correlation coefficients (ICC). Results: There were no significant differences between measurements of method I and II for each observer (p>0.05) and intraobserver reliability were good. (ICC>0.9) Inter-observer reliability for method I and II was good of the HVA (ICCs, 0.912 and 0.905) and moderate of the $IMA_{1-2}$ (ICCs, 0.505 and 0.537). There were interobserver differences in HVA of method I and II. Conclusion: No significant difference was found statistically between measurements of method I and II. Both methods I and II would be acceptable to measure angular parameters of hallux valgus deformity.

Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

  • Silva, Nathalia Cristine da;Barriviera, Mauricio;Junqueira, Jose Luiz Cintra;Panzarella, Francine Kuhl;Raitz, Ricardo
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.11-15
    • /
    • 2017
  • Purpose: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT(Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. Materials and Methods: A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal(distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. Results: All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. Conclusion: It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.