• 제목/요약/키워드: internal value

검색결과 2,611건 처리시간 0.031초

마르텐사이트계 내열강의 금속 및 기계적 특성에 관한 연구 (A Study on the Internal Quality and the Machining Characteristics of Martensitic Heat Resisting Steel)

  • 채왕석;권용기;김동현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.1073-1077
    • /
    • 1997
  • In this paper, we have studied internal quality including chemical compositions, microscopic structure and nonmetalic inclusion of test materials. We have analyzed machining characteristics including tensile strength value, impact value, hardness value etcs. Test materials are usd martensitic heat resisting steel, STR11 and STS420J2. The obtined results are as follows : 1. In analyzing internal quality, STR11 and STR420J2 have typical martensite structure and a minute needle-shaped structure. 2. Tensile strength and reduction of area and hardness value are large STR11 than STS420J2. But elongation impact are smaller STR11 than STS420J2. 3. Fracture surface of tensile speciman is ductile in STR11 and STS420J2.

  • PDF

고객가치, 공급사슬통합 그리고 기업성과 간의 관계에 대한 연구 (A Study on Relationships among Customer Value, Supply Chain Integration, and Business Performance)

  • 주재훈;김진완
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제21권2호
    • /
    • pp.27-44
    • /
    • 2012
  • The goal of supply chain integration is to improve the effectiveness and efficiency of supply chain for creating customer values. Supply chain integration can be classified into IT integration and structural integration. Also, structural integration can be collapsed into three dimensions: internal, supplier and customer integration. In this study, we investigate the relevance between customer value and supply chain integration. To explore the current study, we collected from 73 Korean firms. The results are as follows: First, customer value has a positively significant effect on IT integration. Second, customer value influences on customer integration but does not has an effect on internal and supplier integration. Third, IT integration improve internal, supplier and customer integration. Finally, each of structural integration positively influences firm performance. These results indicated that declaration of customer value is important factor in supply chain integration.

트럭용 커낵팅 로드 소재의 내부 품질에 따른 절삭 특성 연구 (A Study on the Machining Characteristics by the Internal Quality of Conecting Rod's Meterials for Trucks)

  • 김동현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.97-101
    • /
    • 1996
  • In this paper, We have studied internal quality incluiding chemical compositions, microscopic structrue and nonmetalic inclusion of test materials. We have analyzed dynamic characteristics of cutting resistence including tensile strength value, hardeness value, impact value etcs. We have compared chip treatments of test materials. In analyzing internal quality, all of test materials have typical ferrite+pearlite structure. But, nonmetallic inclusion have oxide and sulfide inclusion in medium carbon steels, mainly sulfide inclusion is existed in S-free cutting steels. In Ca+S-free cutting steels, calcium aluminate and sulfide complex inclusion, had low-melting points, as deformation of sulfide and oxide inclusion is existed. machining characteristics, cutting resistence is maximum in Ca+S-free cutting steels, minimum in medium carbon steels. Chip treatements are excellent in S-free cutting steels, similar to the Ca+S free cutting steels and medium carbon steels.

  • PDF

휴대용 폐기능 검사기의 재현성과 기대치에 관한 연구 (Repeatability and Appropriate Predicted Value of Portable Spirometry on Korean Adults)

  • 최준용;정희재;이건영;정승연;황준호;이형구;정승기
    • 대한한방내과학회지
    • /
    • 제26권3호
    • /
    • pp.587-595
    • /
    • 2005
  • Objectives : The object of this study was to evaluate repeatability of portable spirometry and to determine an appropriate equation for predicted value. Materials and Methods : The subjects were 76 men and 45 women recruited from among Kyunghee University oriental medical students. Portable spirometry was performed via the procedure recommended in ATS guidelines. Repeatability of spirometry was checked against ATS repeatability standards and NHLEP QC grade. Percentage of predicted value of non-smokers was calculated through a Caucasian population-based regression equation(by Morris et al.) and Korean population based regression equation(by Kim et al.). These were compared. Result : 91.7% of subjects matched repeatability standards of ATS and 95% of subjects got interpretable NHLEP QC grades of A, B, and C. Mean percentage of predicted value by Morris et al. were as follows: Mean of FVC% was 90.86, FEV1% was 96.66, FEV1/FVC% was 107.48. Mean percentage of predicted value by Kim et al. were as follows. Mean FVC% was 92.38, FEV1% was 89.77, FEV1/FVC% was 96.95. Conclusions : Results of this study show that more than 90% of subjects meet repeatability criteria. This supports a role for the portable spirometer as a primary oriental medical office tool. Further, results are a verify that they Korean population-based predicted value equation is a more appropriate standard than the Caucasian population-based one, but a still more accurate standard is needed for the Korean adult population.

  • PDF

Effect of cyclic loading and retightening on reverse torque value in external and internal implants

  • Cho, Woong-Rae;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.288-293
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. RESULTS. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. CONCLUSION. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.

가미제습순기탕(加味除濕順氣湯)이 고혈압에 미치는 영향 (Effect of KamiJeseupSungi-Tang(KJST) on Hypertension)

  • 문형권;조현경;유호룡;설인찬;김윤식
    • 동의생리병리학회지
    • /
    • 제20권4호
    • /
    • pp.887-895
    • /
    • 2006
  • This study was aimed to elucidate the effects of KamiJeseupSungi-Tang(KJST) on Hypertension by blood pressure, number of pulse, ALT, AST, BUN, creatinine, aldosterone, dopamine, epinephrine, norepinephrine, $Na^+,\;K^+,\;Cl^-,\;Ca^{2+},\;TNF-{\alpha}$, IL-6, IL-10 in Spantaneous Hypertensive Rat(SHR). The results are as follows. The blood pressure was significantly decreased. The value of ALT, AST, BUN, creatinine were significantly decreased. The value of aldosterone, dopamine, epinephrine were significantly decreased. The value of $Na^+,\;K^+,\;Ca^{2+}$ were significantly decreased. The value of TNF-u was significantly decreased. Whit the above result, it is thought that KamiJeseupSungi-Tang(KJST) can be applied effectively to the Hypertension.

내부에너지를 최대로 하는 활 구조의 최적화 (Shape optimization of a bow for maximizing internal-energy)

  • 문명조;이현정
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제5회(2016년)
    • /
    • pp.222-227
    • /
    • 2016
  • In this paper, the optimized design for bow structure was investigated by using EDISON software. Considering the mechanism of the bow, non-linear FEM analysis was essential. The factors of the design are height, width, number of holes and taper value. High performance of the internal energy and lowest mass were main issues. The limit of the von-mises stress was yield strength for the material. Material was chosen by considering typical bow material, Aluminum. Using Taguchi method($L_9$), 9 models were selected and contribution rate was calculated for each factors. Following the contribution rate, 3 factors were fixed and optimized model was predicted. After making optimized model for FEM analysis, the value of internal-energy, mass for FEM model were compared with predicted value, calculated the percentage error and figure out the reliability of Taguchi method.

  • PDF

저용량 He-Ne 레이저 정맥내(靜脈內) 조사(照射)가 혈중(血中) Lipoprotein(a)에 미치는 영향(影響) (Effect of Intravascular Laser Irradiation on Lipoprotein(a))

  • 이동준;선중기;최창원;임진훈
    • 대한한방내과학회지
    • /
    • 제21권5호
    • /
    • pp.839-844
    • /
    • 2000
  • Objectives : The purpose of study was to investigate the effect of ILlB(intravascular laser irradiation of blood) on serum lipoprotein(a) Methods : The 12 case is diagnosed as cerebrovascular diseases on computed tomograghy. The 18 case is not observed abnormality on computed tomograghy but, they have neurological sign. Blood test was enforced on the first medical examination, The 15 case with plasma lipoprotein(a) greater than 30 mg/dl have been classified into abnormal group and the 15 case of less than 30 mg/dl have been classified into control group. after ten times ILlB, It was observed that the change of plasma lipoprotein(a) and a fibrinogen of blood clotting factor. Conclusions : 1. After ten times ILlB, plasma lipoprotein(a) numerical value was decreased on 13 case of abnormal group. 2. Plasma lipoprotein(a) numerical value was decreased on 5 case of control group. 3. The twenty in fifteen patient's with hyperlipoproteinemias have been fibrinogenemias and after ILIB treatment, in the all of 16 case with hyperfibrinogenemia in the first medical examination to both abnormal and control group, plasma fibrinogen numerical value was decreased.

  • PDF

정수지 내부 단락류 발생 평가 : Part A. 정수장 내부 단락류 분석을 통한 장폭비와 형태가 T10/T 값에 미치는 영향 연구 (Internal Short-circuiting Estimation in Clearwell : Part A. Improving T10/T Using Intra Basin and Diffuser Wall by Applying ISEM to Field)

  • 신은허;이승재;김성훈;박희경
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.105-112
    • /
    • 2008
  • Disinfection is a basic and effective microorganism inactivation method and historically contributed a decrease in waterborne diseases. To guarantee the disinfection ability, improving T in CT value is important. Many indexes are used to estimate the hydraulic efficiency, however, these are black-box analysis. Therefore it is need to develope new estimation method. In this study, internal short-circuiting estimation method (ISEM) is developed using CFD and we inquire into the factor which causes increase of $T_{10}/T$ value as LW ratio increases. And the effect of shape on the relation of LW ratio and $T_{10}/T$ is analyzed. As LW ratio increases, internal short-circuiting index (ISI) of influent and effluent zone is rapidly reduced and recirculation and dead zone are reduced in channel zone. Therefore, as the $T_{10}/T$ value converges maximum value, ISI curve is changed from "V" shape to "U" shape and hydraulic efficiency is improved especially in downstream portion of clearwell. The less the shape ratio(width/length of clearwell) is the less the $T_{10}/T$ value is at a same LW ratio because the portion of turning zone increases as shape ration decreases, therefore more boundary separation is generated.

회전 방지용 Post Screw 시스템의 임플랜트 지대나사풀림 방지효과에 관한 연구 (A STUDY OF THE ANTI-ROTATING INNER POST SCREW SYSTEM AS A MEANS OF PREVENTING ABUTMENT SCREW LOOSENING)

  • 김종희;임주환;조인호;이준석
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.671-683
    • /
    • 2005
  • Statement of problem: The most commonly reported problem associated with dental implant restoration is the loosening of the screws. Purpose: This study compared the efficacy of an implant system incorporating an anti-rotational locking sleeve(Anti-Rotating Inner Post Screw System(ARIPS-system)) with other, traditional implant systems as a means of minimizing vibration loosening. Materials and methods: Three implant systems were examined; the conventional external hex type, the ARIPS-system, and the internal taper type implant system 30 specimens(10 samples per group)were fabricated and each abutment screw was secured to the implant future with 32Ncm of torque force and loosening torque was measured using a Torque Gauge. The procedure was repeated 3 times, recording initial loosening torque each time. The re-tightened abutment screw was subjected to a cyclic load having a maximum forte of 200N and minimum of 20N at 2Hz over a period of 12,600 cycles. after which the loosening torque was measured. Measured values were calaulated for statistical analysis. Analysis of measured value was performed by 3 methods: (i) as a percentage average of the initial 3 loosening-torque values(initial loosening value) to the tightening torque of 32Ncm, (ii) as a percentage of the loosening torque value after a load of 200N(experimental value) to the initial loosening value, and (iii) as a percentage of the experimental value to the 32Ncm of tightening torque. The analyses shows the amount of initial loosening at the screw, loosening by repetitive load and the the final loosening value. Results: The results of this study were as follows (1) Percentage of initial loosening value to tightening-torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of external hex, ARIPS-system and internal taper. Value of internal taper showed significant difference with those of external hex and ARIPS-system (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). Conclusion: The results of the analysis of the final loosening level value, which are closely correlated to clinical use, show that the ARIPS-system can be a useful means of minimizing abutment screw loosening when compared to the external hex type system. Although further clinical studies need to be made, the ARIPS-system should be considered to maximize the long-term success of the implant prosthesis.