• Title/Summary/Keyword: internal stability

Search Result 1,118, Processing Time 0.026 seconds

The Proprioceptive Function of Rotator Cuff Tear Patients: Preliminary Report of Pre-operative Function (회전근개 파열 환자의 고유 수용성 감각 기능: 수술전 기능의 예비 보고)

  • Lee, Hyunil;Heo, Jaewon;Yoo, Jae Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • Purpose: Proprioceptive function has been known to be important to shoulder stability. However, the function in rotator cuff tear patients is rarely investigated. The purpose of current study is to report the proprioceptive function in rotator cuff tear patients and to analyze the proprioceptive function regarding the tear size and the presence of subscapularis tear. Materials and Methods: Between 2011 and 2012, total 76 patients (male 28 and female 48) were recruited and average age was 61.7 years old (range, 38~76). Preoperatively, joint position senses in internal and external rotation were measured for proprioceptive function testing by method of active re-positioning technique. The absolute difference from set point was measured. Proprioceptive function was further analyzed according to tear size of rotator cuff, the presence of subscapularis tear, visual analogue scale of pain, shoulder functional score (American society of elbow and shoulder score), and ranges of motion in shoulder. Results: The absolute difference for external rotation was $4.9^{\circ}{\pm}2.9^{\circ}$, in normal joint and $4.9^{\circ}{\pm}3.0^{\circ}$for involved joint in rotator cuff tear patients. This difference was not significant statistically (p=0.87). The absolute difference for internal rotation was $4.0^{\circ}{\pm}2.7^{\circ}$in normal joint whereas $4.8^{\circ}{\pm}3.7^{\circ}$ for involved joint showing statistically significant difference (p=0.043). There was some trend that the proprioceptive function of internal rotation was more impaired in the bigger tear size group (more than medium tear) compared to the smaller tear size group (partial thickness and small tear, 5.0 vs. 4.0, p=0.061). The impairment of internal rotation proprioception was also accentuated in patients with subscapularis tear (4.8 vs. 4.0, p=0.065). The proprioceptive function of internal rotation was decreased when the pain visual analogue scale was increased (5.2 vs. 4.0 p=0.04), shoulder functional score was decreased (6.1 vs. 4.2, p=0.005), or range of motion in shoulder joint was restricted (5.3 vs. 3.7, p=0.041). Conclusion: The deficit of proprioceptive function was observed in rotator cuff tear patients. Proprioception for internal rotation was impaired in patients with the bigger tear size and subscapularis tear. Pain, shoulder function score, and range of motion were also shown to be related with the deficit in proprioceptive function.

  • PDF

Assessment of the Effect of a Public Health Clinics' Home-Based Terminal Cancer Patient Management in Collaboration with a Regional Cancer Center (경남 지역 암센터와 보건소 재가암환자 관리 서비스와의 연계 사업)

  • Song, Haa-Na;Kang, Myoung Hee;Lee, Gyeong Won;Kim, Hoon Gu;Lee, Won Sup;Kang, Jung Hun;Kang, Yoon Sik;Eun, Young
    • Journal of Hospice and Palliative Care
    • /
    • v.16 no.1
    • /
    • pp.10-19
    • /
    • 2013
  • Purpose: Home-based care providers were surveyed to assess the effect of collaborative service between Gyeongnam Regional Cancer Center (GRCC) and public health centers (PHCs) in Gyeongnam province. Methods: Twenty home-based care providers who had previously participated in the GRCC-PHC care project were recruited from nine PHCs and were surveyed using a questionnaire developed by specialists. Questions were rated using the 5-point Likert scale ranging from "strongly disagree (-2)" to "strongly agree (+2)" and each score was multiplied by the corresponding number of respondents (n=20) with the maximum score of 40. Results: Between January 2008 and December 2011, 73 patients were registered to the collaborative service: 72 by GRCC and one by PHC. Home-based care providers marked the highest score (23 points) to "The collaborative service contributed to patients and their family's psychological stability" and the lowest score (11 points) to "The collaborative service was generally helpful for home-based cancer management." For possible suggestions to improve the service, the highest score (35 points) was given to "Simplification of the hospitalization process" followed by "Substantial benefits for patients at their visit to the hospital" (34 points). Conclusion: The results revealed several limitations of the GRCC-PHC collaborative care service for terminal cancer patients. The service could be further improved by developing measures to address the limitations and a service model tailored to region-specific needs.

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.

Serial MR Imaging of Magnetically Labeled Humen Umbilical Vein Endothelial Cells in Acute Renal Failure Rat Model (급성 신부전 쥐 모델에서 자기 표지된 인간 제대정맥 내피세포의 연속 자기공명영상)

  • Lee, Sun Joo;Lee, Sang Yong;Kang, Kyung Pyo;Kim, Won;Park, Sung Kwang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.181-191
    • /
    • 2013
  • Purpose : To evaluate the usefulness of in vivo magnetic resonance (MR) imaging for tracking intravenously injected superparamagnetic iron oxide (SPIO)-labeled human umbilical vein endothelial cells (HUVECs) in an acute renal failure (ARF) rat model. Materials and Methods: HUVECs were labeled with SPIO and poly-L-lysine (PLL) complex. Relaxation rates at 1.5-T MR, cell viability, and labeling stability were assessed. HUVECs were injected into the tail vein of ARF rats (labeled cells in 10 rats, unlabeled cells in 2 rats). Follow-up serial $T2^*$-weighted gradient-echo MR imaging was performed at 1, 3, 5 and 7 days after injection, and the MR findings were compared with histologic findings. Results: There was an average of $98.4{\pm}2.4%$ Prussian blue stain-positive cells after labeling with SPIOPLL complex. Relaxation rates ($R2^*$) of all cultured HUVECs at day 3 and 5 were not markedly decreased compared with that at day 1. The stability of SPIO in HUVECs was maintained during the proliferation of HUVECs in culture media. In the presence of left unilateral renal artery ischemia, $T2^*$-weighted MR imaging performed 1 day after the intravenous injection of labeled HUVECs revealed a significant signal intensity (SI) loss exclusively in the left renal outer medulla regions, but not in the right kidney. The MR imaging findings at days 3, 5 and 7 after intravenous injection of HUVECs showed a SI loss in the outer medulla regions of the ischemically injured kidney, but the SI progressively recovered with time and the right kidney did not have a significant change in SI in the same period. Upon histologic analysis, the SI loss on MR images was correspondent to the presence of Prussian blue stained cells, primarily in the renal outer medulla. Conclusion: MR imaging appears to be useful for in vivo monitoring of intravenously injected SPIO-labeled HUVECs in an ischemically injured rat kidney.

Marginal bone loss between internal- and external- abutment connection type implants placed in the first molar area (제1대구치 위치에 식립된 단일 임플란트의 지대주 연결 유형에 따른 임플란트 주위골 흡수)

  • Seok-Hyun Lee;Eun-Woo Lee;Ha-Na Jung;Ok-Su Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.32-44
    • /
    • 2023
  • Purpose: The purpose of this study was to investigate the effect of implant connection type on marginal bone loss (MBL) and to analyze the factors that affect MBL. This study focuses on single implants planted in the upper and lower first molar area. Materials and Methods: A total of 87 implants from 68 patients were tracked for a period over 5 years. There were 57 external connection type (EC) implants and 30 internal connection type (IC) implants in 38 males and 30 females. The MBL and EA were measured from intraoral radiograph images taken after 5 years at most. Results: Significant difference in MBL between EC and IC type was observed in patients without GBR or diabetes. Patients without GBR exhibited an MBL of -0.065 ± 0.859 mm in EC type and -0.627 ± 0.639 mm in IC type (P = 0.025). Using multiple regression analysis, a statistically significant negative correlation was observed between MBL and conditions including implant-abutment connection type (β = -0.303), diabetes (β = -0.113), emergence angle > 30° (β = -0.234), and age (β = -0.776). Conclusion: Within this results, IC type implants had less MBL than EC type, and implant prosthesis with emergence angle over 30° showed greater MBL. To minimize the MBL of the implant and ensure implant stability, careful consideration should be given to the EA of implant prosthesis and its connection type.

Soil Mechanical Properties and Stability Analysis on Fill Slope of Forest Road (임도성토사면(林道盛土斜面)의 토질역학적(土質力學的) 특성(特性)과 안정해석(安定解析))

  • Ji, Byoung Yun;Oh, Jae Heun;Cha, Du Song
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.275-284
    • /
    • 2000
  • This study was carried out to analyze the mechanical properties of soil and the slope stability on the fill slope of forest road constructed in the regions which consist of igneous and metamorphic rock area. The results were summarized as follows. 1) Soil type by Unified Soil Classification System(USCS) was classified as SW in soil slope, GP in weathered rock slope, GP in soft rock slope for both types of parent rock, but gravelly soil slopes in igneous and metamorphic rock area were classified as SP and GW, respectively. 2) Dry unit weight was $1.34g/cm^2{\sim}1.59g/cm^2$, specific gravity 0.57~0.61, and void ratio 0.66~0.93 in the case of igneous rock area, a dry unit weight was $1.35g/cm^2{\sim}1.51g/cm^2$, specific gravity 2.67~2.77, and void ratio 0.78~1.01 in the case of metamorphic rock area. 3) The strength parameters such as internal friction angle(${\phi}$) and cohesion(c) were selected and tested for slope stability analysis. ${\phi}$ and c of soil in igneous rock area were within the range of $29.51^{\circ}{\sim}41.82^{\circ}$ and $0.03kg/cm^2{\sim}0.38kg/cm^2$, respectively, and $21.43^{\circ}{\sim}41.43^{\circ}$ and $0.05kg/cm^2{\sim}0.44kg/cm^2$ in metamorphic rock area, respectively. 4) Result of the slope stability analysis of forest road showed that, in the weathered rock slope of igneous rock and the weathered rock and soil slope of metamorphic rock area, the possibility of slope failure was high as safety factor was below 1.0.

  • PDF

Study on the storage stability of the white internal organs using natural materials (천연소재를 활용한 백내장의 저장성 증진 연구)

  • Han, Ye-Jin;Ku, Su-Kyung;Kim, Tae-Kyung;Sung, Jung-Min;Kim, Young-Boong;Choi, Yun-Sang
    • Food Science and Preservation
    • /
    • v.25 no.1
    • /
    • pp.145-154
    • /
    • 2018
  • The purpose of this study was to investigate the ability of natural antioxidants as stabilizers for meat by-products to prevent lipid oxidation. The white internal organs were evaluated using different treatments: no antioxidant (control), ascorbic acid (T1), Artemisiacapillaris Thunb. (T2), Opuntia (T3), Schisandra chinensis (T4), and Saururuschinensis (Lour.) Baill (T5). Antioxidant activities were analyzed by measuring DPPH contents, superoxide anion radical levels, nitrate scavenging activities, and total polyphenol contents. T1 and T2 showed higher antioxidant activities and total polyphenol contents (p<0.05). Additionally, changes in physicochemical properties (pH, color, volatile basic nitrogen [VBN], and thiobarbituric acid reactive substances [TBARS]) and microbiological aspects in white internal organs processed with antioxidants were investigated. As storage time increased, the CIE $a^*$ and $b^*$ values of the white internal organs processed with natural antioxidants were decreased (p<0.05), and CIE $L^*$ values were low, particularly for the T3 sample relative to that in the control. Moreover, the pH, VBN, and TBARS values of samples T2-T5 were increased after 7 days of storage, but showed low values compared with those of the control (p<0.05). Moreover, compared with the control group, the treatments showed antimicrobial effects. Our results indicated that these natural antioxidants could be used as lipid oxidation stabilizers of meat by-products during storage and that Artemisiacapillaris Thunb. and Opuntia may have applications as natural antioxidants in the meat by-product industry.

An Experimental Study on Overflow and Internal Erosion Protection Technology of a Reservoir (저수지 제체월류 및 내부침식 보호기술 모형실험 연구)

  • Jin, Ji-Huan;Lee, Tae-Ho;Yoo, Jeon-Yong;Im, Eun-Sang;Lee, Seung-Joo;Kim, Yong-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.181-191
    • /
    • 2019
  • Most of the reservoirs in South Korea are fill dam, and overflow and piping phenomena have been detected as the main causes of failure of fill dam. In this study, an operating ◯◯ reservoir located in Gongju-si is modeled in centrifuge model test to study the behavior of reservoir during water level rise and overflow conditions. In order to simulate seepage and overflow in the real reservoir, the model was constructed in 1/50 scale, and deteriorated and reinforced conduits were installed. After modeling the reinforced and deteriorated conditions of the conduits, LVDTs, pore pressure gauges were installed and centrifuge model tests were carried out with water level rise and overflow conditions in order to analyze the reservoir behavior according to the reinforcement methods. The results of centrifuge model test in water level rise condition show that deteriorated conduit has adverse effects in the stability of the reservoir body, and the conduit which is reinforced by the inverse lining method has enhanced stability of the reservoir body. Moreover, installation of water spillway is seen to prevent the scour and erosion of the reservoir body. The study provides a basic data required for the reinforcement of conduit and water spillway in the reservoir.

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.

Dispersion Characteristics of Carbon Black Particles in a High Viscous Simulated Solution (고점성 모사용액 내 Carbon Black 입자의 분산특성)

  • Jeong, Kyung-Chai;Eom, Sung-Ho;Kim, Yeon-Ku;Cho, Moon Sung
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.165-170
    • /
    • 2013
  • An external gelation method in place of an internal gelation method applied to the fabrication process of an intermediated compound of Uranium Oxy-Carbide (UCO) kernel spheres for Very High Temperature Reactor (VHTR) fuel preparation is under development in Korea. For the preliminary experiments of the UCO kernel sphere preparation using an external gelation method, the carbon black dispersion experiments were carried out using a simulated broth solution. From the selection experiments of various kinds of carbon black through dispersion experiments in a viscous metal salt solution, Cabot G carbon black was selected owing to its dispersion stability, and the homogeneous dispersing state of carbon black particles in our system. For the effective dispersion of nano-size aggregated carbon black particles in a high viscous liquid, the carbon black particles in a metal salt solution were first de-aggregated with ultrasonic force. The mixed solution was then dispersed secondly by the use of the extremely high-speed agitation with a mechanical mixer of 6000 rpm after feeding the Poly Vinyl Alcohol (PVA) in the solution. This results in the broth solution with good stability and homogeneity alongside no further changes in physical properties.