• Title/Summary/Keyword: internal sampling frequency

Search Result 28, Processing Time 0.028 seconds

A Performance Evaluation of the MPEG USAC with Variable Core-Band Down-Sampling Ratio (가변 핵심 대역 하향 표본화 비를 가진 MPEG USAC 성능 평가)

  • Lee, Jae Hwa;Kim, Rin Chul
    • Journal of Broadcast Engineering
    • /
    • v.18 no.1
    • /
    • pp.106-114
    • /
    • 2013
  • This paper deals with the effect of the internal sampling frequency and core band down sampling ratio on the overall performance of the MPEG USAC. Here, the internal sampling frequency is the sampling frequency of a signal actually coded. The core band down sampling ratio is the ratio of the width of the core band over that of the coded band. The performance was measured on 6 different test sound sources by the MUSHRA test with 10 subjects. The experiments showed that 1/3 or 1/4 core band down sampling ratio could yield the better performance than the conventional 1/2 ratio, especially at low rates.

Phase-Locked Three-Dimensional Structures in the Cylinder Wake Observed from Cinematic PIV Data (Cinematic PIV에 의한 실린더 후류의 위상평균된 3차원 구조)

  • Sung, Jae-Yong;Park, Kang-Kuk;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.661-666
    • /
    • 2000
  • Near-wake flow field of a circular cylinder is studied by means of a cinematic PIV system with high sampling rate and large internal memory block. Experiments are conducted in a closed-cycle water tunnel system and a cross-correlation algorithm in conjunction with FFT (Fast Fourier Transform) analysis and an offset correlation technique is used for vector processing. With the help of very high sampling frequency compared to the shedding frequency, it is possible to obtain phase-averaged information of the three-dimensional wake, even though the shedding is not forced but natural. Phase-locked vortical structures observed simultaneously from the spanwise and cross-stream planes are displayed in the wake-transition regime where fine-scale secondary vortices have a spanwise wavelength or around one diameter. Spatial relations and temporal evolutions of the primary Karman vortex and the secondary vortex are also discussed schematically.

  • PDF

Relationship between oral health locus of control and oral health behavior promotion in the adolescents (청소년의 구강건강 통제의 소재와 구강건강증진행위와의 관계)

  • Kim, Im-Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.4
    • /
    • pp.575-582
    • /
    • 2015
  • Objectives: The purpose of the study was to investigate the relationship between oral health locus of control and oral health behavior promotion in the adolescents. Methods: A self-reported questionnaire was completed by 493 high school students in Jeonju by convenience sampling from March to June, 2014. The questionnaire consisted of fourteen questions of oral health locus of control, fifteen questions of oral health behavior promotion, and seven questions of the general characteristics of the subjects. Data analysis was done by frequency analysis, t-test, ANOVA, and Duncan's multiple range test. Results: Oral health behavior promotion and oral health behavior index of internal locus of control showed a positive correlation, Higher internal locus of control showed a positive oral health behavior promotion. The higher propensity of oral health on the external locus of control showed the negative effects. Conclusions: The oral health internal locus of control was closely related to better oral health behavior in the adolescents.

Design of Robust Double Digital Controller to Improve Performance for UPS Inverter (UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계)

  • 박지호;노태균;김춘삼;안인모;우정인
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.116-127
    • /
    • 2003
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an Internal model controller The Internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

Development of Digital Controller and Monitoring System for UPS Inverter (UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발)

  • Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

0.11-2.5 GHz All-digital DLL for Mobile Memory Interface with Phase Sampling Window Adaptation to Reduce Jitter Accumulation

  • Chae, Joo-Hyung;Kim, Mino;Hong, Gi-Moon;Park, Jihwan;Ko, Hyeongjun;Shin, Woo-Yeol;Chi, Hankyu;Jeong, Deog-Kyoon;Kim, Suhwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.3
    • /
    • pp.411-424
    • /
    • 2017
  • An all-digital delay-locked loop (DLL) for a mobile memory interface, which runs at 0.11-2.5 GHz with a phase-shift capability of $180^{\circ}$, has two internal DLLs: a global DLL which uses a time-to-digital converter to assist fast locking, and shuts down after locking to save power; and a local DLL which uses a phase detector with an adaptive phase sampling window (WPD) to reduce jitter accumulation. The WPD in the local DLL adjusts the width of its sampling window adaptively to control the loop bandwidth, thus reducing jitter induced by UP/DN dithering, input clock jitter, and supply/ground noise. Implemented in a 65 nm CMOS process, the DLL operates over 0.11-2.5 GHz. It locks within 6 clock cycles at 0.11 GHz, and within 17 clock cycles at 2.5 GHz. At 2.5 GHz, the integrated jitter is $954fs_{rms}$, and the long-term jitter is $2.33ps_{rms}/23.10ps_{pp}$. The ratio of the RMS jitter at the output to that at the input is about 1.17 at 2.5 GHz, when the sampling window of the WPD is being adjusted adaptively. The DLL consumes 1.77 mW/GHz and occupies $0.075mm^2$.

Effects of the Team Trust Element of Rugby Players on Self-Determination Motive and Team Performance

  • Lee, Jin-Wook;Park, Sung-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.8
    • /
    • pp.107-114
    • /
    • 2018
  • This study was conducted for the purpose of examining the effects of team trust element of rugby players on self-determination motive and team performance. As for the study subjects, rugby players participated in the 97th national athletic meet in 2016 were selected. As for data collection, in the total of 221 copies of samples were collected through convenience sampling method and 182 copies were used for the final analysis. Using SPSS 18.0, the collected data were analyzed through frequency analysis, exploratory factor analysis, Cronbach's ${\alpha}$ test, correlation analysis and multiple regression analysis and the following conclusions have been obtained. First, as for the effects of rugby players' team trust element on self-determination motive, it was found that team trust influenced external moderation, internal moderation, integrated moderation and identification moderation, and teammate trust influenced internal moderation, integrated moderation and identification moderation. Second, as for the effects of rugby players' team trust element on team performance, it was found that team trust and teammate trust influenced team performance. Third, as for the effects of rugby players' self-determination motive on team performance, it was found that integrated moderation and internal moderation influenced team performance.

Experimental Model for the Biology Curriculum in Junior and Senior High School Using Cells and Animals 1. Sampling and classification of protists (중.고등학교 생물교과 과정의 세포 및 동물실험 모델의 개발에 관한 연구 1. 원생생물의 채집 및 분류를 중심으로)

  • Ahn, Tae-In;Chung, Hae-Moon;Kim, Hyun-Chung;Choi, Ji-Young
    • Journal of The Korean Association For Science Education
    • /
    • v.7 no.2
    • /
    • pp.21-35
    • /
    • 1987
  • Polyurethane foam was utilized to collect protists from the 2 ponds in Seoul National University and another pond in vicinity of Paldang Dam. The identified protists were 4 species in Cyanophyta, 2 species in Euglenophyta, 19 species in Chrysophyta, 9 species in Chlorophyta, 2 species in Ciliophora, and 3 species in Sarcodian. To test the adoptability of the sampling method for classes in junior and senior high school, frequency of the 25 protists in each observation and in each preparation were calculated. The families which were present at high frequencies were Naviculaceae. Fragilariaceae, Cymbellaceae and Coelastraceae. In an experimental application of the 40 pictures taken from the samples, students in junior classes recognized the protists by their outer morphology, internal structure. color, and colonial types, in decreasing order. Use of the collecting method and the applicability of protists for teaching biology were discussed.

  • PDF

Development of Constant Output Power Supply System for Ozonizer (오존발생장치용 정출력 전원장치의 개발)

  • Woo, Jung-In;Woo, Sung-Hoon;Roh, In-Bae;Park, Jee-Ho;Kim, Dong-Wan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.113-121
    • /
    • 2005
  • In this paper, a constant output power supply system for ozonizer is proposed to remove the noise of ozonizer and control the output of ozonizer using feedback control. The proposed system is based on the rouble control loop such as the outer voltage control loop and inner current control loop. In the proposed system overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the experimental results.

Effects of Electroacupuncture on Immobilization Stress Responses : A Study on Inhibitory Avoidance Task, Forced Swimming Test, and Stress Hormones (전기침이 결박 스트레스 반응에 미치는 영향 : 억제성 회피 과제, 강제 수영 시험, 스트레스 호르몬 반응 연구)

  • Kwon, So-Yeon;Kim, Min-Soo;Lee, Sang-Kwan;Je, Jun-Tae;Oh, Jae-Gun;Lee, Jong-Deok;Sung, Kang-Keyng
    • The Journal of Internal Korean Medicine
    • /
    • v.32 no.1
    • /
    • pp.100-112
    • /
    • 2011
  • Objectives : This study investigated the effects of electroacupuncture on memory, depression, and plasma stress hormone levels in rats that were under immobilization stress. Materials and Methods : The immobilization-only group was given two hours of immobilization stress for 10 consecutive days. The immobilization and high frequency EA group was given two hours of immobilization stress simultaneously with high frequency (100Hz) electroacupuncture stimulation on the right ST-36 (Zusanli) for 10 consecutive days. We conducted the inhibitory avoidance and forced swimming tests to recognize whether immobilization stress and electroacupuncture have effects on memory and depression. We collected blood samples from the tail of each rat at 30, 60, 90, and 120-minute intervals during the immobilization stress and EA stimulation to measure plasma concentrations of ACTH, corticosterone, melatonin, and norepinephrine induced by immobilization stress and electroacupuncture. Results : There was a significant effect of high frequency on the increase in anamnesis based on the result of the inhibitory avoidance test, but there was no significant effect of decreasing depression based on the result of the forced swim test. Also, there was no significant effect on the response indicated by stress hormones. Conclusions : 1. High frequency electroacupuncture (100Hz) improved anamnesis in immobilization stress states under the inhibitory avoidance task. 2. High frequency electroacupuncture (100Hz) did not reduce depression induced by immobilization stress under the forced swimming test. 3. High frequency electroacupuncture (100Hz) did not decrease stress hormones through blood sampling.