• Title/Summary/Keyword: internal pressures

Search Result 229, Processing Time 0.03 seconds

A Study on the Forging of Cylindrical Parts with Internal Serrations (내부에 세레이션홈이 존재하는 원통형 제품의 단조에 관한 연구)

  • Park, J.C.;Cho, H.Y.;Min, G.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.6
    • /
    • pp.142-148
    • /
    • 1997
  • In this paper, forging of internal triangular and involute serrations are analyzed by upper bound method. Kinematically admissible velocity fields for half pitch of the serration were proposed. It was assumed that the shape flow surface during forging is a straight line perpendicular to plane of symmetry. Using the suggested velocity fields, forging loads and relative pressures were calculated by numerical method. Experiments were carride out with commercial AI 2024 aluminium alloy. As a result, the calculated solutions are good agreement with experimental results, so it is useful to predict the loads for forging of internal serrations.

  • PDF

Analysis of three dimensional equivalent static wind loads of symmetric high-rise buildings based on wind tunnel tests

  • Liang, Shuguo;Zou, Lianghao;Wang, Dahai;Huang, Guoqing
    • Wind and Structures
    • /
    • v.19 no.5
    • /
    • pp.565-583
    • /
    • 2014
  • Using synchronous surface pressures from the wind tunnel test, the three dimensional wind load models of high-rise buildings are established. Furthermore, the internal force responses of symmetric high-rise buildings in along-wind, across-wind and torsional directions are evaluated based on mode acceleration method, which expresses the restoring force as the summation of quasi-static force and inertia force components. Accordingly the calculation methods of equivalent static wind loads, in which the contributions of the higher modes can be considered, of symmetric high-rise buildings in along-wind, across-wind and torsional directions are deduced based on internal forces equivalence. Finally the equivalent static wind loads of an actual symmetric high-rise building are obtained by this method, and compared with the along-wind equivalent static wind loads obtained by China National Standard.

Investigation of Turbulent Spray Disintegration Characteristics Depending on the Nozzle Configuration

  • Lee, Sam-Goo;Song, Kyu-Keun;Park, Byung-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.572-579
    • /
    • 2002
  • The experimental measurements were carried out to examine turbulent disintegration characteristics ejecting from a counter-flowing internal mixing pneumatic nozzle under variable conditions of swirl angles and air pressures. The air injection pressure was varied from 60 kPa to 180 kPa and four counter-flowing internal mixing nozzles with axi-symmetric tangential-drilled holes at swirl angle of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$to the central axis have been specially designed. The experimental results were quantitatively analyzed, focusing mainly on the comparison of turbulent atomization characteristics issuing from an internal mixing swirl nozzle. To illustrate the swirl phenomena, the distributions of mean velocities, turbulence intensities, volume flux, and SMD (Sauter Mean Diameter, or D$\sub$32/) were comparatively analyzed.

Pretest analysis of a prestressed concrete containment 1:3.2 scale model under thermal-pressure coupling conditions

  • Qingyu Yang;Jiachuan Yan;Feng Fan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2069-2087
    • /
    • 2023
  • In nuclear power plant (NPP) accidents, the containment is subject to high temperatures and high internal pressures, which may further trigger serious chain accidents such as core meltdown and hydrogen explosion, resulting in a significantly higher accident level. Therefore, studying the mechanical performance of a containment under high temperature and high internal pressure is relevant to the safety of NPPs. Based on similarity principles, the 1:3.2 scale model of a prestressed concrete containment vessel (PCCV) of a NPP was designed. The loading method, which considers the thermal-pressure coupling conditions, was used. The mechanical response of the PCCV was investigated with a simultaneous increase in internal pressure and temperature, and the failure mechanism of the PCCV under thermal-pressure coupling conditions was revealed.

A Study on the Forging of Internal Involute Gears with Alloy Steel (합금강을 이용한 내접 인벌류우트 기어의 단조에 관한 연구)

  • 최종웅;조해용;최재찬
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.2
    • /
    • pp.90-98
    • /
    • 1998
  • Forging of internal involute gears with alloy steel has been analyzed by means of upper bound method. Kinematically admissible velocity fields for forging of internal gear were proposed. It was assumed that the shape of free flow surface during forging operation is a straight line perpendicular to the plane of symmetry. Using the suggested velocity fields, forging loads and relative pressures were calculated by numerical method. Consequently forging die should be successfully designed without fracture or failure during forging operation. Experiments were carried out with the designed die and SCM415 alloy steel as billet material. The calculated loads were compared with experimental one and they are in good agreement with experimental inspections. As a result, the calculated solutions would be useful to predict the loads and the designed die is suitable for forging of internal involute spur gear with alloy steel. The forged gear is measured to be KS 4 class and its class should be improved by subsequent working such as shaving after forging operation.

  • PDF

Discharging Performance in Length of Hard Labyrinth and Pressure of Cylinder Type Drip Irrigation Hose (원통형 점적기의 압력과 경질미로의 길이에 따른 토출 특성)

  • Kim, Jin Hyun;Woo, Man Ho;Kim, Dong Eok
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.103-109
    • /
    • 2018
  • The performance of drip irrigation devices depends on flow uniformity related to the function of pressure compensation. The flow uniformity can be secured when the internal fluid pressures at the positions of the flow holes are maintained uniformly. The pressure compensation effect of the drip irrigation devices can be optimized with the combination of soft silicon and labyrinth structures. However, for a drip irrigation devices composed of only hard labyrinth structures, the flow rate is changed largely with the length and the internal geometry of the labyrinth structure. Although a drip irrigation devices with only hard labyrinth structures can be fabricated simply, the changes of flow rates with internal fluid pressures are much larger than those of the drip irrigation devices with soft silicon. Because the drip irrigation devices with only labyrinth structures can be utilized widely through the optimization of the fluid pressure, the length of the structures, and the cross-sectional area of them, the study on the optimization can play an important role for enhancing the performance of the drip irrigation devices. In this study, experimental and numerical studies for investigating the performance of the drip irrigation devices had been conducted. In the experiments and numerical calculations(CFD), the variable parameters were the lengths of the labyrinth structures(#1~#8) and the fluid pressures(0.5~3.0 bar).

A study on the working mechanism of internal pressure of super-large cooling towers based on two-way coupling between wind and rain

  • Ke, Shitang;Yu, Wenlin;Ge, Yaojun
    • Structural Engineering and Mechanics
    • /
    • v.70 no.4
    • /
    • pp.479-497
    • /
    • 2019
  • In the current code design, the use of a uniform internal pressure coefficient of cooling towers as internal suction cannot reflect the 3D characteristics of flow field inside the tower body with different ventilation rate of shutters. Moreover, extreme weather such as heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind. In this study, the world's tallest cooling tower under construction, which stands 210m, is taken as the research object. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed iteratively using continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind speed and rainfall intensity on the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower body is analyzed. The combination of wind velocity and rainfall intensity that is most unfavorable to the cooling tower in terms of distribution of internal pressure coefficient is identified. On this basis, the wind/rain loads, distribution of aerodynamic force and working mechanism of internal pressures of the cooling tower under the most unfavorable working condition are compared between the four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the amount of raindrops captured by the internal surface of the tower decreases as the wind velocity increases, and increases along with the rainfall intensity and ventilation rate of the shutters. The maximum value of rain-induced pressure coefficient is 0.013. The research findings lay the basis for determining the precise values of internal surface loads of cooling tower under extreme weather conditions.

J Estimations For Axial Surface Cracked Pipes Under Pressure (축방향 표면균열이 존재하고 내압을 받는 직관의 J 예측 방법)

  • Oh, Chang-Sik;Song, Tae-Kwang;Kim, Yun-Jae
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1824-1829
    • /
    • 2007
  • In the present paper, limit pressures for axial surface cracked pipe are proposed, and a reference stress based J estimation method is also provided based on the proposed limit pressure solutions. Employed cracks are assumed to be constant-depth, internal surface cracks, and wide ranges of variables are considered.

  • PDF

Lubrication Characteristics of High Performance Oil Hydraulic Vane Pump (고성능 유압 베인펌프의 윤활특성)

  • 정재연
    • Tribology and Lubricants
    • /
    • v.9 no.1
    • /
    • pp.45-54
    • /
    • 1993
  • The lubrication characteristics of line contacts between the vane and cam ring in an oil hydraulic vane pump with intravanes have been investigated. Variations of the radial acting force of a vane were calculated from previously measured results of dynamic internal pressures in four chambers surrounding a vane, and variations of the film thickness were estimated in both the rotational speed range from 500 to 1500 rpm and in the delivery pressure range from 1 to 14 MPa. The results indicate the variations of the radial acting force and film thickness. It is found that the regimes of lubrication in the vane tip contacts lover rigid-isoviscous to rigidvariable viscosities.

A Paradigm for the Viscosity of Fluids

  • Kim, Won-Soo;Chair, Tong-Seek;Pak, Hyung-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.9 no.4
    • /
    • pp.213-217
    • /
    • 1988
  • A new paradigm for the viscosity of fluid is presented by considering the fact that the viscosity is equal to the shear stress divided by the shear rate. The shear stress is obtained from the sum of kinetic and internal pressures of fluid, and the shear rate is found from the phonon velocity divided by the mean free path of the phonon. The calculated viscosities for various simple substances are in excellent agreements with those of the observed data through the wide temperature range covered both of liquid and gas phase.