• Title/Summary/Keyword: internal magnetic field

Search Result 113, Processing Time 0.025 seconds

Construction of Magnetic Resonance Imaging Inside-out probes for Internal Imaging (핵자기공명 영상법을 위한 내부 영상용 뒤집음-탐침의 제작)

  • Ko, R.K.;Lee, D.H.;Jeong, E.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.78-81
    • /
    • 1995
  • In imaging the samples or human internal organs in a tube shape, general RF-probe types (that encircles a sample or places on top of the sample) are usually unsuitable for the internal imaging due to the degradation of signal-to-noise ratios(SNR's). In the present study the inside-out probes for Magnetic Resonance Imaging (MRI) have been constructed in the three different shapes such as an anti-solenoidal, a saddle and a dual surface types which are positioned as close to the area as possible by putting the probe inside the tubelike sample to improve filling factor. RF-field distributions have also been calculated depending upon the geometrical changes of anti-solenoid probes. Moreover, the performance of the inside-out probes has been checked by measuring SNR's of the images acquired. The inside-out probes constructed in this study produced better SNR's and rf-field uniformity in the area close to the probes in comparing with any other commercial probes. There is a high possibility that the constructed probes in the present study are applicable to the diagnosis of human bodies.

  • PDF

Monte Carlo Calculation on the Dose Modulation Using Dynamic Magnetic Fields for 10 MV X-rays (움직이는 자기장을 이용한 10 MV X-선의 선량변조에 관한 몬테칼로 계산)

  • Kim, Ki Hwan;Oh, Young Kee;Shin, Kyo Chul;Kim, Jhin Kee;Jeong, Dong Hyeok;Kim, Jeung Kee;Cho, Moon June;Kim, Sun Young
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.221-225
    • /
    • 2007
  • Monte Carlo calculations were performed to demonstrate the dose modulation with dynamic magnetic fields in phantom. The goal of this study is to obtain the uniform dose distributions at a depth region as a target on the central axis of photon beam under moving transverse magnetic field. We have calculated the depth dose curves for two cases of moving magnetic field along a depth line, constant speed and optimal speed. We introduced step-by-step shift and time factor of the position of the electromagnet as an approximations of continuous moving. The optimal time factors as a function of magnetic field position were calculated by least square methods using depth dose data for static magnetic field. We have verified that the flat depth dose is produced by varying the speed of magnetic field as a function of position as a results of Monte Carlo calculations. For 3 T magnetic field, the dose enhancement was 10.1% in comparison to without magnetic field at the center of the target.

  • PDF

Heat Treatment Effects of $Fe_{73.0}Cu{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$Alloy with Imbedded Nanocrystalline Phase under Magnetic Field (초미세결정립과 비정질이 공존하는 $Fe_{73.9}$$Cu_{1.0}$$Nb_{3.5}$$Si_{14.0}$$B_{7.6}$ 합금의 자기장 중 열처리)

  • Yang, J.S.;Son, D.;Cho, Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.1
    • /
    • pp.13-20
    • /
    • 1998
  • The crystallographic and high frequency characteristics of $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ soft magnetic alloys were investigated under the magnetic field annealing. As-cast ribbon with which already imbedded nanocrystalline Fe-Si phase on the surface have a preferred orientation with (400) plane to surface and also with the [011] direction parallel to the ribbon length. The extra nanocrystalline Fe-Si phase appeared throughout at 45$0^{\circ}C$ in samples with or without the longitudinal magnetic field. However the formation of nanocrystalline phase does not appear on the suface layer until 50$0^{\circ}C$ annealing temperature under the transverse field. The cryststallization fraction of annealed samples with longitudinal magnetic field is higher than that of samples without magnetic field. When the transverse magnetic field is applied, the crystallization fraction does not increases but decreases until 50$0^{\circ}C$. However the crystallization of internal regions can be confirmed by X-ray diffraction measurement via tilting the sample. It was found that for all samples, the saturation induction were all same with 1.3 T. The coercive field of as-cast sample was 1.06 A/cm, but in annealed samples it decrease from 0.56 to 0.1 A/cm with increasing annealing temperature from 400 and 55$0^{\circ}C$, respectively. The squareness of annealed samples under transverse magnetic field has a small value than that of both without field and with longitudinal field annealing.

  • PDF

Study of Weak Astrophysical Shock Waves using a PIC Code

  • Kwon, Hye-Won;Ryu, Dong-Su
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.109.1-109.1
    • /
    • 2011
  • Shock waves are ubiquitous in astrophysical environments. In particular, shocks formed by merger of subclumps, infall of matter and internal flow motion in intracluster media (ICMs) and cluster outskirts are relatively weak with Mach number M ${\lesssim}$ a few. At such weak shocks, it has been believed that the diffusive shock acceleration (DSA) of cosmic rays is rather inefficient. Yet, the presence of nonthermal phenomena, such as radio halos and relics, suggests that contrary to the expectation, DSA as well as magnetic field amplification should operate at weak shocks in cluster environments. We recently initiated a study of weak, collisionless, astrophysical shocks using a PIC(Particle-in-Cell) code. The PIC code describes the motion of electron and ion particles under the electromagnetic field which is represented in grid zones. Here, we present a preliminary work of one-dimensional simulations. We show how shocks are set up as the turbulent electromagnetic field is developed in the shock transition layer, and discuss the implication on DSA and magnetic field amplification.

  • PDF

Ultra Finishing by Magnet-abrasive Grinding for Internal-face of STS304 Pipe (STS304 파이프 내면의 초정밀 자기연마)

  • 김희남;윤영권;심재환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.947-952
    • /
    • 1997
  • The magnetic polishing is the useful method to finish using magnetic power of a magnet. The time hasn't been that long since the magnetic polishing method was introduced to korea as one of precision polishing techniques. However, the reasons for not being spreaded widely are the magnetic polishing method don't have mediocrity for machine, the efficiency of magnet-abrasive is confined as a bad polishing, and there are not many researchers in this field. The mechanism of this R&D is dealing with the dynamic state of magnet-abrasive. This paper deals with mediocritizing magnetic polishing device into regular lathe and this experiment was conducted in order to get a best surface roughness with low cost. Beside the subsidiary experiment was performed using the mixed magnet-abrasive with general alumina, barium. This paper introduced the main reason for difficulty using this method in industrial field. It needs more continues research on it. This paper contains the result of experiment to acquire the best surface roughness, not using the high-cost polishing material in processing. The average diameters of magnet-abrasive are the particles of 150 $\mu\textrm{m}$, 250 $\mu\textrm{m}$.

  • PDF

Polarization properties and single-mode operation of an internal-mirror 543 nm He-Ne laser (내부 반사경 543 nm 헬륨 네온 레이저의 편광특성과 단일모드 동작)

  • 김경찬;서호성;엄태봉
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.403-407
    • /
    • 1998
  • The polarizatin properties of an internal-mirror 543 nm He-Ne laser with and without a transverse magnetic field were investigated for single-mode operation. Two orthogonal eigenpolarizations field to the natural tube axes of laser were observed when the emitted laser output was linearly polarized. Polarization unstability between these polarizations occurred when the applying a 500 gauss transverse magnetic field at 35$^{\circ}$ with respect to the natural tube axes of laser. Under such conditions stable single-mode operation which is useful for the frequency stabilization of a 543 He-Ne laser to $I_2$-saturated absorptions was obtained in the tuning range of 880 MHz.

  • PDF

Parallel Load Techinques Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.27-32
    • /
    • 2012
  • Transcranial magnetic stimulation requires an electric field composed of dozens of V/m to achieve stimulation. The stimulation system is composed of a stimulation coil to form the electric field by charging and discharging a capacitor in order to save energy, thus requiring high-pressure kV. In particular, it is charged and discharged in capacitor to discharge through stimulation coil within a short period of time (hundreds of seconds) to generate current of numerous kA. A pulse-type magnetic field is formed, and eddy currents within the human body are triggered to achieve stimulation. Numerous pulse forms must be generated to initiate eddy currents for stimulating nerves. This study achieved high internal pressure, a high number of repetitions, and rapid switching of elements, and it implemented numerous control techniques via introduction of the half-bridge parallel load method. In addition it applied a quick, accurate, high-efficiency charge/discharge method for transcranial magnetic stimulation to substitute an inexpensive, readily available, commercial frequency condenser for a previously used, expensive, high-frequency condenser. Furthermore, the pulse repetition rate was altered to control energy density, and grafts compact, one-chip processor with simulation to stably control circuit motion and conduct research on motion and output characteristics.

3-Port Circulator for X-Band Radar (X-Band 레이더를 위한 3-포트 서큘레이터)

  • Yoon, Sung-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.355-362
    • /
    • 2015
  • In this study, we have fabricated 9.385[GHz] circulator that is composed of WR112 waveguide and Ferrite for X-band radar. For designing Ferrite, B/R mode(Below Resonance mode) was used and calculated the condition of 120 degree rotation of the electric field in Ferrite and calculated internal DC magnetic field and external DC magnetic field. Also, dielectric materials of the same shape with Ferrite was filled between two Ferrite for improving the performance of the circulator, including impedance matching, bandwidth, quality factor, insertion loss. To obtain optimum shape of the Ferrite and dielectric material, we used CST MWS. Simulation result of the circulator is that 1.02 : 1 VSWR, -40dB isolation, 0.2dB insertion loss and measurement result is that 1.03 : 1, -38dB, 1.2dB at 9.385[GHz]. We can get good agreement at isolation and VSWR, but insertion loss was 1 dB great than simulation result.

Synthesis of Permalloy (Ni-Fe) Nanosheets through Sonoelectrochemical Methods and its Magnetic Properties

  • Rhee, Ryan;Moon, Kyounghoon;Yoo, Bongyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.4
    • /
    • pp.202-206
    • /
    • 2018
  • Permalloy($Ni_{80}-Fe_{20}$) which is known for its soft magnetic properties is a well-known material that has been studied intensively. Permalloy nanoflakes were fabricated with the combination of electrodeposition and sonication process. Ultrasonic power was applied to the deposited alloy which produced nanoflakes in forms of sheet. High internal stress created cracks which helped the peeling of permalloy into nanosheets. Because of shape anisotropy, flakes could be aligned by magnetic field. The magnetic properties of the nanosheets were observed, and the variation of magnetic properties with the alignment of flake was also investigated.

Analysis and measurement of low frequency magnetic field according to internal position of electric railway train (전기철도차량 객실 내부 위치에 따른 극저주파 자계 측정 및 분석)

  • Jang, Dong-Uk;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.489-494
    • /
    • 2008
  • The measurement of magnetic field is performed about DC and AC magnetic field in electric railway line. The test point is cap, on the converter/inverter box, on the traction motor and on the SIV, the height of measurement is bottom and 60 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through BNC output, DAQ cad and notebook PC.

  • PDF