• Title/Summary/Keyword: internal gas

Search Result 1,306, Processing Time 0.03 seconds

Development of standard gas mixtures of hydrocarbons in methane contained in aluminum cylinders (알루미늄 실린더에서 혼합 탄화수소(C6-C10) 표준가스 개발)

  • Kim, Yong-Doo;Bae, Hyun-Kil;Woo, Jin-Chun;Lee, Sangil;Oh, Sang-Hyub;Lee, Jin Hong
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.287-294
    • /
    • 2017
  • As the demand for natural gas increases with industrial development, the supply of natural gas is expected to become unstable with a shortage of imported natural gas. It is hence necessary to meet this demand by introducing and developing various types of natural gas, such as pipeline natural gas (PNG) and substituted natural gas (SNG), in addition to liquefied natural gas (LNG). The components included in PNG as well as their concentrations must be measured accurately, and a standard gas should be developed to accurately measure hydrocarbons ($C_6-C_{10}$), which are trace components included in natural gas. The components in the primary standard gas mixtures (PSMs) developed in the present study were hexane, heptane, octane, nonane, and decane with concentrations of $10-30{\mu}mol/mol$ with methane as the balance gas. Standard hydrocarbon ($C_6-C_{10}$) gas mixtures were prepared in aluminum cylinders by a gravimetric method with traceability following ISO 6142 with raw material gases, for which the purity of each component was analyzed completely. The prepared standard gas mixtures were analyzed by to evaluate the preparation consistency between the standard gas mixtures, the adsorbability of the cylinders, the variation of the stability, and the uncertainty. The results showed that aluminum cylinders have little adsorptive loss on their internal surfaces with excellent long-term stability. The developed standard gas mixture, containing hexane, heptane, octane, nonane, and decane with concentrations of $10-30{\mu}mol/mol$, showed an uncertainty in a range of 0.79 % - 1.63 %.

Effect of Chlorine Dioxide Gas Application to Egg Surface: Microbial Reduction Effect, Quality of Eggs, and Hatchability

  • Chung, Hansung;Kim, Hyobi;Myeong, Donghoon;Kim, Seongjoon;Choe, Nong-Hoon
    • Food Science of Animal Resources
    • /
    • v.38 no.3
    • /
    • pp.487-497
    • /
    • 2018
  • Controlling of microorganisms in the industrial process is important for production and distribution of hatching and table eggs. In the previous study, we reported that chlorine dioxide ($ClO_2$) gas of a proper concentration and humidity can significantly reduce the load of Salmonella spp. on eggshells. In this study, we compared microbial reduction efficacy on egg's surface using hatching eggs and table eggs, internal quality of table eggs, and hatchability after both the conventional method (washing and UV expose, fumigation with formalin) and $ClO_2$ gas disinfection. Application of 40 ppm $ClO_2$ gas to the table and hatching eggs, respectively, reduced the aerobic plate count (APC) with no statistical difference compared with the conventional methods. Additionally, we didn't observed that any significant difference in albumin height, Haugh unit (HU), and yolk color, this result confirms that 40 ppm $ClO_2$ had no effect on the internal quality of the table eggs, when comparing with the UV treatment method. The hatchability of hatching eggs was not statistical different between formaldehyde fumigation and 80 ppm $ClO_2$ gas treatment, though the value was decreased at high concentration of 160 ppm $ClO_2$ gas. From these results, we recommend that $ClO_2$ gas can be used as a safe disinfectant to effectively control egg surface microorganisms without affecting egg quality.

Structural Integrity Evaluation by System Stress Analysis for Fuel Piping in a Process Plant (공정플랜트 연료배관의 시스템응력 해석에 의한 구조 건전성 평가)

  • Jeong, Seong Yong;Yoon, Kee Bong;Duyet, Pham Van;Yu, Jong Min;Kim, Ji Yoon
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.44-50
    • /
    • 2013
  • Process gas piping is one of the most basic components frequently used in the refinery and petrochemical plants. Many kinds of by-product gas have been used as fuel in the process plants. In some plants, natural gas is additionally introduced and mixed with the byproduct gas for upgrading the fuel. In this case, safety or design margin of the changed piping system of the plant should be re-evaluated based on a proper design code such as ASME or API codes since internal pressure, temperature and gas compositions are different from the original plant design conditions. In this study, series of piping stress analysis were conducted for a process piping used for transporting the mixed gas of the by-product gas and the natural gas from a mixing drum to a knock-out drum in a refinery plant. The analysed piping section had been actually installed in a domestic industry and needed safety audit since the design condition was changed. Pipe locations of the maximum system stress and displacement were determined, which can be candidate inspection and safety monitoring points during the upcoming operation period. For studying the effects of outside air temperature to safety the additional stress analysis were conducted for various temperatures in $0{\sim}30^{\circ}C$. Effects of the friction coefficient between the pipe and support were also investigated showing a proper choice if the friction coefficient is important. The maximum system stresses were occurred mainly at elbow, tee and support locations, which shows the thermal load contributes considerably to the system stress rather than the internal pressure or the gravity loads.

Comparison of Respiratory Mechanics and Gas Exchange Between Pressure-controlled and Volume-controlled Ventilation (압력조절환기법과 용적조절환기법의 호흡역학 몇 가스교환의 비교)

  • Jeong, Seong-Han;Choi, Won-Jun;Lee, Jung-A;Kim, Jin-A;Lee, Mun-Woo;Shin, Hyoung-Shik;Kim, Mi-Kyeong;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.662-673
    • /
    • 1999
  • Background : Pressure-controlled ventilation (PCV) is frequently used recently as the initial mode of mechanical ventilation in the patients with respiratory failure. Theoretically, because of its high initial inspiratory flow, pressure-controlled ventilation has lower peak inspiratory pressure and improved gas exchange than volume-controlled ventilation (VCV). But the data from previous studies showed controversial results about the gas exchange. Moreover, the comparison study between PCV and VCV with various inspiration : expiration time ratios (I : E ratios) is rare. So this study was performed to compare the respiratory mechanics and gas exchange between PCV and VCV with various I : E raitos. Methods : Nine patients receiving mechanical ventilation for respiratory failure were enrolled. They were ventilated by both PCV and VCV with various I : E ratios (1 : 2, 1 : 1.3 and 1.7 : 1). $FiO_2$, tidal volume, respiratory rate and external positive end-expiratory pressure (PEEP) were kept constant throughout the study. After 20 minutes of each ventilation mode, arterial blood gas, airway pressures, expired $CO_2$ were measured. Results : In both PCV and VCV, as the I : E ratio increased, the mean airway pressure was increased, and $PaCO_2$ and physiologic dead space fraction were decreased. But P(A-a)$O_2$ was not changed. In all three different I : E ratios, peak inspiratory pressure was lower during PCV, and mean airway pressure was higher during PCV. But $PaCO_2$ level, physiologic dead space fraction and P(A-a)$O_2$ were not different between PCV and VCV with three different I : E ratios. Conclusion : There was no difference in gas exchange between PCV and VCV under the same tidal volume, frequency and I : E ratio.

  • PDF

Finite Element Analysis on the Deformation Behavior Safety of a Gas Valve (가스밸브의 변형거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.70-75
    • /
    • 2017
  • This paper presents the FEM analysis results on the deformation behavior safety of automatic cut-off horizontal and conventional vertical gas valves. Based on the FEM analysis, the primary maximum deformation of $4.4{\mu}m$ was formed on the right end side of a valve body when the internal gas pressure was supplied on the screw port and gas discharge port of an automatic cut-off horizontal gas valve. And the secondary maximum deformation of $2.9{\mu}m$ was formed on the end side of safety valve port. This small deformation of an automatic cut-off horizontal gas valve is strongly related to the balanced design of a horizontal gas valve main body, which is composed of a screw part, gas outlet port, port for a stem and spindle shaft assembly, and safety valve port. But, the primary maximum deformation of 0.076mm was formed on the upper part of a conventional automatic cut-off vertical gas valve when the internal gas pressure was supplied on the screw port and gas discharge port. And the secondary maximum deformation of 0.055mm was formed on the left end side of a gas outlet port. This may effect on the sealing clearance of o-ring that is inserted on the groove of an automatic cut-off unit. Thus, this paper recommends an automatic cut-off horizontal gas valve compared with that of a conventional gas valve for a gas leakage free mechanism of a LPG cylinder valve.

Suitability Judgment of Storage Conditions by Internal Gas Concentration of 'Fuji' Apples under CA Storage (CA저장 중 후지 사과의 내부 기체농도에 의한 저장조건의 적합성 판단)

  • Chung, Hun-Sik;Choi, Jong-Uck
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1295-1299
    • /
    • 1999
  • This study was conducted to develop a index for the judgment of suitability of storage conditions by internal gas concentration of 'Fuji' apples under CA storage, and was examined the relationship between the levels of quality characteristics(flesh firmness, titratable acidity and surface green color) and the infernal ethylene and carbon dioxide concentrations of apples. The levels of quality characteristics were not decreased for terms of storage when the infernal ethylene concentration of apples was below 10 ppm, but the levels of quality characteristics were sharply decreased when it was above 10 ppm of Internal ethylene. The high levels of quality characteristics were maintained by the lower internal carbon dioxide concentration of apples, especially at below 2% of internal carbon dioxide. These result showed that the suitable condition for CA storage of 'Fuji' apples was a condition for having below 10 ppm of internal ethylene and below 2% of internal carbon dioxide in apples. The internal ethylene and carbon dioxide concentrations of apples during CA storage can be used as a crucial index for the suitability judgment of storage conditions.

  • PDF

Evaluation of Tongue Coating by Digital Tongue Diagnosis System between Halitosis and Non-Halitosis Patients. (디지털 설진기를 이용한 구취군과 비구취군 간의 설태 평가)

  • Jung, Yong-Jae;Kim, Jin-Sung;Oh, Sung-Hwan;Han, Ga-Jin;Kim, Yoo-Seung;Hong, In-A;Park, Young-Sun;Park, Jae-Woo;Park, Kyung-Mo;Ryu, Bong-Ha
    • The Journal of Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.23-29
    • /
    • 2010
  • Objective: The aim of this prospective, case-controlled study was to assess the difference of the amount of tongue coating between halitosis and non-halitosis patients using a digital tongue diagnosis system (DTDS). Methods: Sixty-five patients complaining of oral malodor were recruited for the study. The level of volatile sulfur compounds (VSC) in the oral cavity of the patients was measured by a portable gas chromatography. All patients were then divided into two groups, the halitosis group ($H_2S{\geq}1.5ng$/10ml, or $CH_3SH{\geq}0.5ng$/10ml) and the non-halitosis group ($H_2S$<1.5ng/10ml and $CH_3SH$<0.5ng/10ml), according to the VSC level criteria published by Tonzetich. Tongue images of the two groups were acquired and analyzed by DTDS, followed by the analysis of the tongue coating scores. Results: The tongue coating scores of the halitosis group were significantly higher than of the non-halitosis group (P=0.033). Furthermore, the difference of the posterior tongue coating between the two groups was more significant (P=0.000). Conclusions: Halitosis patients were shown to have a thicker tongue coating than those in the non-halitosis group. Moreover, the posterior dorsum of the tongue should be observed more cautiously when dealing with halitosis patients. Also, the progress and state of the patient's symptom of halitosis as diagnosed objectively by the portable gas chromatography could also possibly be analyzed instead by the DTDS tongue coating score.

Performance Analysis of R-1270(Propylene) Refrigeration System Using Internal Heat Exchanger (내부 열교환기를 이용한 R-1270용 냉동시스템의 성능 분석)

  • Ku, Hak-Keun
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.36-42
    • /
    • 2014
  • This paper considers the influence of internal heat exchangers on the efficiency of a refrigerating system using R-1270. These internal heat exchangers(liquid-gas or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed. The main results were summarized as follows : the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, and effectiveness have the influences on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. With a thorough grasp of it is possible to design the R-1270 compression refrigeration cycle using internal heat exchanger.

Analysis of Diethylcarbamazine and Diethylcarbamazine-N-oxide by Gas Chromatography

  • Lee, Suk-Hyang;M.S;Pharm.D
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.475-479
    • /
    • 1996
  • Diethylcarbamazine (DEC, 1-diethylcarbamyl-4-methylpiperazine) is an antiparasitic piperazine derivative used in the treatment of lymphatic filariasis caused by Wuchereria bancrofti, Brugia malayi or grugia timori. DEC-N-oxide is a major metabolite in humans and has antifilarial activity. In carrying out pharmacokinetic studies, gas chromatographic analysis of DEC in plasma can be complicated by the presence of the metabolite, since the thermally unstable DEC-N-oxide is converted back to a material which coelutes with DEC under the conditions of the analysis. We now report a method to separate DEC-N-oxide from DEC in plasma using solid phase extraction with subsequent gas chromatographic analysis using a nitrogen specific detector. One-diethylcarbamyl-4-ethylpiperazine (E-DEC) was the internal standard. The standard curve of DEC was linear in the range of 10 to 200 ng/ml as described by Y=0.0350+0.0128X, $R^2=0.999$. The limit of quantitation was 4 ng/mL. Reproducibility at 10, 100 and 200 ng/mL concentration points of the standard curve gave coefficient variations of 6.1%, 7.8% and 1.6%, respectively. The recovery following solid phase extraction was 99.3% for DEC and 94.8% for the internal standard. This sensitive and specific analytical method is suitable for pharmacokinetic studies of DEC.

  • PDF