• 제목/요약/키워드: internal electrodes

검색결과 164건 처리시간 0.03초

Application of NiOx Anode for Bottom Emission Organic Light Emitting Diode

  • Kim, Young-Hwan;Kim, Jong-Yeon;Kim, Byoung-Yong;Han, Jeong-Min;Moon, Hyun-Chan;Park, Kwang-Bum;Seo, Dae-Shik
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.448-448
    • /
    • 2007
  • OLED has many advantages of low voltage operation, self radiation, light weight, thin thickness, wide view angle and fast response time to overcome existing liquid crystal display (LCD)'s weakness. Therefore, It draws attention as promising display and has already developed for manufactured goods. Also, OLED is regarded as a only substitute of flexible display with a thin display. However, Indium tin oxide(ITO) thin film for electrode of OLED shows a low electrical properties and is impossible to deposit at high thermal condition because electrical characteristics of ITO is getting worse. One of the ways to realize an improved flexible OLED is to use high internal efficiency electrodes, which have higher work function than those single layer of ITO films of the same thickness. The high internal efficiency electrodes film is developed with structure of nickel oxide for bottom Emission Type of OLED.

  • PDF

Electrochemical Removal Efficiency of Pollutants on ACF Electrodes

  • Oh, Won-Chun;Park, Joung-Sung;Lee, Ho-Jin;Yum, Min-Hyung
    • Carbon letters
    • /
    • 제5권4호
    • /
    • pp.191-196
    • /
    • 2004
  • The electrochemical removal (ECR) of water pollutants by activated carbon fiber (ACF) electrodes from wastewater was investigated over wide range of electrochemical reaction time. The ECR capacities of ACF electrodes were associated with their internal porosity and were related to physical properties and to reaction time. And, surface morphologies and elemental analysis for the ACFs after electrochemical reaction are investigated by SEM and EDX to explain the changes in adsorption properties. The FT-IR spectra of ACFs for the investigation of functional groups show that the electrochemical treatment is consequently associated with the homogeneous removal of pollutants with the increasing surface reactivity of the activated carbon fiber surfaces. The ACFs were electrochemically reacted to waste water to investigate the removal efficiency for the COD, T-N and T-P. From these removal results of pollutants using ACFs substrate, satisfactory removal performance was obtained. The outstanding removal effects of the ACFs substrate were determined by the properties of the material for adsorption and trapping of organics, and catalytic effects.

  • PDF

No-Touch Radiofrequency Ablation Using Twin Cooled Wet Electrodes for Recurrent Hepatocellular Carcinoma Following Locoregional Treatments

  • Seong Jun Hong;Jae Hyun Kim;Jeong Hee Yoon;Jeong Hoan Park;Jung-Hwan Yoon;Yoon Jun Kim;Su Jong Yu;Eun Ju Cho;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • 제25권5호
    • /
    • pp.438-448
    • /
    • 2024
  • Objective: To evaluate the therapeutic outcomes of no-touch radiofrequency ablation (NT-RFA) using twin cooled wet (TCW) electrodes in patients experiencing recurrent hepatocellular carcinoma (HCC) after undergoing locoregional treatments. Materials and Methods: We conducted a prospective, single-arm study of NT-RFA involving 102 patients, with a total of 112 recurrent HCCs (each ≤ 3 cm). NT-RFA with TCW electrodes was implemented under the guidance of ultrasonography (US)-MR/CT fusion imaging. If NT-RFA application proved technically challenging, conversion to conventional tumor puncture RFA was permitted. The primary metric for evaluation was the mid-term cumulative incidence of local tumor progression (LTP) observed post-RFA. Cumulative LTP rates were estimated using the Kaplan-Meier method. Multivariable Cox proportional hazard regression was used to explore factors associated with LTP. Considering conversion cases from NT-RFA to conventional RFA, intention-to-treat (ITT; including all patients) and per-protocol (PP; including patients not requiring conversion to conventional RFA alone) analyses were performed. Results: Conversion from NT-RFA to conventional RFA was necessary for 24 (21.4%) out of 112 tumors. Successful treatment was noted in 111 (99.1%) out of them. No major complications were reported among the patients. According to ITT analysis, the estimated cumulative incidences of LTP were 1.9%, 6.0%, and 6.0% at 1, 2, and 3 years post-RFA, respectively. In PP analysis, the cumulative incidence of LTP was 0.0%, 1.3%, and 1.3% at 1, 2, and 3 years, respectively. The number of previous locoregional HCC treatments (adjusted hazard ratio [aHR], 1.265 per 1 treatment increase; P = 0.004), total bilirubin (aHR, 7.477 per 1 mg/dL increase; P = 0.012), and safety margin ≤ 5 mm (aHR, 9.029; P = 0.016) were independently associated with LTP in ITT analysis. Conclusion: NT-RFA using TCW electrodes is a safe and effective treatment for recurrent HCC, with 6.0% (ITT analysis) and 1.3% (PP analysis) cumulative incidence of LTP at 2 and 3-year follow-ups.

No-Touch vs. Conventional Radiofrequency Ablation Using Twin Internally Cooled Wet Electrodes for Small Hepatocellular Carcinomas: A Randomized Prospective Comparative Study

  • Yun Seok Suh;Jae Won Choi;Jeong Hee Yoon;Dong Ho Lee;Yoon Jun Kim;Jeong Hoon Lee;Su Jong Yu;Eun Ju Cho;Jung Hwan Yoon;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • 제22권12호
    • /
    • pp.1974-1984
    • /
    • 2021
  • Objective: This study aimed to compare the efficacy between no-touch (NT) radiofrequency ablation (RFA) and conventional RFA using twin internally cooled wet (TICW) electrodes in the bipolar mode for the treatment of small hepatocellular carcinomas (HCC). Materials and Methods: In this single-center, two-arm, parallel-group, prospective randomized controlled study, we performed a 1:1 random allocation of eligible patients with HCCs to receive NT-RFA or conventional RFA between October 2016 and September 2018. The primary endpoint was the cumulative local tumor progression (LTP) rate after RFA. Secondary endpoints included technical conversion rates of NT-RFA, intrahepatic distance recurrence, extrahepatic metastasis, technical parameters, technical efficacy, and rates of complications. Cumulative LTP rates were analyzed using Kaplan-Meier analysis and the Cox proportional hazard regression model. Considering conversion cases from NT-RFA to conventional RFA, intention-to-treat and as-treated analyses were performed. Results: Enrolled patients were randomly assigned to the NT-RFA group (37 patients with 38 HCCs) or the conventional RFA group (36 patients with 38 HCCs). Among the NT-RFA group patients, conversion to conventional RFA occurred in four patients (10.8%, 4/37). According to intention-to-treat analysis, both 1- and 3-year cumulative LTP rates were 5.6%, in the NT-RFA group, and they were 11.8% and 21.3%, respectively, in the conventional RFA group (p = 0.073, log-rank). In the as-treated analysis, LTP rates at 1 year and 3 years were 0% and 0%, respectively, in the NT-RFA group sand 15.6% and 24.5%, respectively, in the conventional RFA group (p = 0.004, log-rank). In as-treated analysis using multivariable Cox regression analysis, RFA type was the only significant predictive factor for LTP (hazard ratio = 0.061 with conventional RFA as the reference, 95% confidence interval = 0.000-0.497; p = 0.004). There were no significant differences in the procedure characteristics between the two groups. No procedure-related deaths or major complications were observed. Conclusion: NT-RFA using TICW electrodes in bipolar mode demonstrated significantly lower cumulative LTP rates than conventional RFA for small HCCs, which warrants a larger study for further confirmation.

The Performance Analysis of Direct Current Electromagnetic Propulsion in Seawater

  • Kong, Yeong-Kyung;Park, Tai-In;Kim, Yun-Sik;Noh, Chang-Joo
    • 에너지공학
    • /
    • 제2권1호
    • /
    • pp.38-44
    • /
    • 1993
  • Electromagnetic seawater thrusters may be classified into four general categories : internal duct dc, external field dc, internal peristaltic ac, and external peristaltic ac. Internal duct dc thrusters offer the advantages of low magnetic field leakage, simple construction, and potentially high reliability. The most efficient internal duct configuration consists of converging inlet nozzle and a straight discharge duct. Ideal efficiency calculations based on the one-dimensional Bernoulli equation show that thrusters should be designed with large cross-sectional areas and operate at low discharge velocities. In practice, this may be accomplished by using multiple thruster ducts. Conductivity enhancement, high magnetic fields, and long electrodes will also improve efficiency.

  • PDF

탄화온도가 상이한 활성탄소 복합제 전극이 전기이중층 케페시터의 층방전 특성에 미치는 영향 (Effect of carbonization temperature of AC/C composite electrode on electro double layer capacitor)

  • 조영근;정두환;김창수;박소진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1821-1823
    • /
    • 1999
  • Carbon is an attractive material on electro double capacitor which depend on charge storage in the electrode/electrolyte interfacial double layer. Carbonaceous material for double layer capacitor can be obtained from carbon powder, fiber, film and porous carbon sheet. The capacitance of electrodes using an activated carbon was influenced by a filling density of the carbon, thickness and internal resistance of the electrode. In this study. to reduce internal resistance and increase electric conductivity of the electrode. activated carbon/carbon(AC/C) composite electrode was fabricated. The capacitors which have energy densities of 68F/g(at $30^{\circ}C$), 109F/g(at $60^{\circ}C$) and $68F/cm^3$(at $30^{\circ}C$), $111F/cm^3$(at $60^{\circ}C$) were fabricated by using AC/C composite electrodes.

  • PDF

변압기 부분방전 상시 감시기법에 관한 연구 (A Study on the on Line Monitoring Techniques of the Partial Discharge for Transformer)

  • 권동진;박재준
    • 한국전기전자재료학회논문지
    • /
    • 제14권12호
    • /
    • pp.1032-1040
    • /
    • 2001
  • In order to apply the partial discharge measuring technique utilizing electrical pulse to the transformer at sites, this paper describes the measuring technique obtaining only the signals due to internal partial discharge in the transformer, but the noises due to external corona which has been a major problem so far. At first, partial discharge and corona noise were simultaneously generated in the model transformer by using needle-plane electrodes and rod-sphere electrodes out of it in a high voltage laboratory, respectively. It was verified that only the partial discharge signals in the transformer could be measured by removing the noise signals from the superposed signals of partial discharges and noises on the grounding wire of the model transformer. By application to a 345kV transformer in service, it was also confirmed that the partial discharge could be on-line monitored by removing the noise signals measured by the inductance sensor on the grounding wire of a 154kV lightning arrester from the superposed signals of internal partial discharge and external corona noise measured by bushing tap coupler of the transformer.

  • PDF

적층형 압전 세라믹 액추에이터에 대한 Ag-세라믹 복합소재 전극의 응용 (Application of Ag-Ceramic Composite Electrodes to Piezoelectric Multilayer Ceramic Actuators)

  • 김성훈;이용희;조성열;최문석;이재신;김일원;정순종;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.331-332
    • /
    • 2006
  • Ag-ceramic composite materials were investigated as internal electrodes for multilayer ceramic actuators (MLCA). Ag-ceramic pastes were prepared by adding PZT-based ceramic powders to a Ag patse in a range of 0 to 50 wt.%. PZT/Ag-PZT multilayered laminates were fabricated by tape casting and fired at low temperatures below $950^{\circ}C$. The addition of ceramic into the Ag electrode resulted in a decrease in the thermal expansion mismatch between the electrode and the ceramic sheet. The maximum strain of PZT/Ag-PZT multilayered actuators were $9{\times}10^{-4}$ under an electric field of 2.5MV/m. In conclusion, Ag-PZT composite materials are efficient for low cost piezoelectric MLCAs.

  • PDF

Studies on Multi-step Addition of NMP in (LiNi0.80Co0.15Al0.05) (NCA) Cathode Slurry Preparation and its Rheological, Mechanical Strength and Electrochemical Properties for Li-ion Cells

  • Vasudevarao Pasala;Satyanarayana Maddukuri;V. Sethuraman;Rekha Lankipalli;Devi Gajula;Venkateswarlu Manne
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권3호
    • /
    • pp.262-271
    • /
    • 2023
  • For electrode stability and the electrochemical performance of the Li-ion cell, it is essential that the active ingredients and unique additives in the polymer binder be well dispersed with the solvent-based slurry. The efficient procedure used to create the slurry affects the rheological characteristics of the electrode slurry. When successively adding different steps of Nmethyl-2-pyrrolidone (NMP) solvent to the cathode composition, it is evenly disseminated. The electrochemical performance of the Li-ion cells and the electrodes made with slurry formed by single step and multiple steps of addition of NMP solvent are examined. To preform rheological properties of cathode electrode slurry on Ni-rich Lithium Nickel-Cobalt-Aluminum Oxide (LiNi0.80Co0.15Al0.05) (NCA). Also, we investigate different step addition of electrode formation and mechanical strength characterization like peel strength. According to the EIS study, a multi-step electrode slurry has lower internal resistance than a single-step electrode slurry, which results in better electrical characteristics and efficiency. Further, microstructure of electrodes is obtained electrochemical performance in the 18650 cylindrical cells with targeted capacity of 1.5 Ah. The slurry of electrodes prepared by single step and multiple steps of addition of NMP solvent and its effect on the fabrication of 1.5 Ah cells. A three-step solvent addition on slurry has been found to be a lower internal resistance than a single-step electrode slurry as confirmed by the EIS analysis, yielding improved electrical properties and efficiency.

적층형 ZnO바리스터의 내부전극과 Bi$_2$O$_3$ 와의 반응 (The Reaction of Internal Electrodes with Bi$_2$O$_3$ in Multilayer ZnO Varistor)

  • 김영정;김환;홍국선;이종국
    • 한국세라믹학회지
    • /
    • 제35권11호
    • /
    • pp.1121-1129
    • /
    • 1998
  • Reactions between Ag-Pd internal electrode materials and{{{{ { {Bi }_{2 }O }_{3 } }} in multilayer chip varistor were in-vestigated. For more than 1 mol%{{{{ { {Bi }_{2 }O }_{3 } }} in varistor composition internal electrode structure was destroyed due to the reaction between internal electrode and{{{{ { {Bi }_{2 }O }_{3 } }} But for typical varistor compositions (below 1 mol% of{{{{ { {Bi }_{2 }O }_{3 } }} content) microstructural changes around the internal electrode were not observed. However SEM-EDS and TEM-EDS analysis showed the uneven distribution of{{{{ { {Bi }_{2 }O }_{3 } }} in the internal electrode which was due to the migration of{{{{ { {Bi }_{2 }O }_{3 } }} to the electorde during sintering. As a results the nonlinear coefficient of multilayer varistor showed very large distribution as well as the breakdown voltage.

  • PDF