• Title/Summary/Keyword: internal electrode

Search Result 278, Processing Time 0.028 seconds

Electrochemical Properties of Porous Carbon Electrode as a Function of Internal Electrolyte Concentration (전극 내부의 전해질 농도 변화에 따른 다공성 탄소전극의 전기화학적 특성)

  • Park, Byeong-Hee;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.20 no.6
    • /
    • pp.700-704
    • /
    • 2009
  • The electrochemical properties of porous carbon electrodes as a function of their internal electrolyte concentration were investigated. Cyclic voltammetry, chronoamperometry, and impedance spectroscopic analysis were conducted for carbon electrodes equilibrated with 0.01, 0.05, 0.1, and 0.5 M KCl solution and covered with a cation-exchange membrane. The specific capacitance of the electrodes increased as the internal electrolyte concentration increased, due to a decrease in charging resistance. Experimental results indicated that the salt removal efficiency of the membrane capacitive deionization process could be enhanced by increasing the internal electrolyte concentration, even for an influent with a low salt concentration.

Fabrication of Gel-type Electrolyte for the Development of Reference Electrode for Sea Water and Application to Measuring Equipment for Total Residual Oxidants (해수용 기준전극 개발을 위한 겔 타입 내부전해질 제조 및 잔류염소 측정장치에의 적용)

  • Kim, Yu-Jin;Lee, Hae-Don;Kim, Dae-Won
    • Applied Chemistry for Engineering
    • /
    • v.28 no.2
    • /
    • pp.153-157
    • /
    • 2017
  • Gel type internal electrolytes were synthesized by varying hydroxyethyl-cellulose (HEC) amounts and their durability and conductivity were measured. The ionic conductivity decreased as the content of HEC increased thus the internal electrolyte containing more than 12% of HEC could not be used as a reference electrode. Based on durability test results, as the HEC amount decreased carrier density resulting in increasing of the amount of KCl coming out of the porous membrane. Therefore in order to use long time at ballast water treatment systems, we selected 10% HEC for gel type internal electrolyte. The resolution test for total residual oxidants (TRO) was carried out using the TRO sensor and the gel type reference electrode made of 10% HEC. A 50 mV potential was applied to the TRO sensor for 30 sec and changes in the current were measured. It was confirmed that the TRO concentrations ranging from 0 to 15 mg/L could be separated at salinity conditions of 0.2~30 PSU. The results indicated that the TRO concentration at sea water and at fresh water was successfully measured by the TRO sensor constructed with the reference electrode using gel-type internal electrolyte of HEC.

The Effect of Needle Electrode in the Static Charge Elimination Methodes for Streaming-Electrification Insulating Oil (유동대전된 절연유의 제전방식중 침전극 삽입의 영향 (IV))

  • Chung, K.H.;Lim, H.C.;Kim, Y.W.;Hwang, M.W.;Paek, Y.C.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1202-1204
    • /
    • 1995
  • In this paper, We investigated a charge elimination by using a needle electrode in order to prevent the electrification phenomena of insulating oil flowing by force at the internal transformer. In our experiment, We used Acryle and Teflon as the material of charge reducer and measured each of their streaming current and needle electrode current. As a result of experiment, We can explain that the current of needle electrode increase in proportion to insulation of charge reducer.

  • PDF

Skin Impedance Measurements Using the Characteristics of Compound Electrode (복합형 전극의 특성을 이용한 피부의 전기저항 측정에 관한 연구)

  • 우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.47-54
    • /
    • 1992
  • We studied the characteristics of the compound electrode and found that the compound electrode provides the four-electrode method in a compact form. We developed a new method of measuring the skin impedance using simple electrodes at low frequencies. At high frequencies where the effect of internal tissue impedance is not negligible, we used the compensation method using compound electrodes since they measure the voltage right under the skin. At 50 kHz, we measured the real part of the skin impedance of less than $80{\Omega}$ on the thorax. We propose a simple instrument which can measure accurate skin impedance at various frequencies.

  • PDF

Die-Sinking Electrical Discharge Machining with Dielectric Fluid Ejection System through the Inside of the Electrode (전극봉내 방전유 분산시스템에 의한 형조방전기공)

  • 왕덕현;우정윤
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • Experimental study if die-sinking electrical discharge machining(EDM) was conducted with rotating electrode system including inside hole for increasing the material removal rate(MRR). With the help of dielectric fluid flow through the inside according to the different internal diameter of the hole, the molten workpiece debris could be removed and flushed out during the EDM, Cold die alloy(SKD-1) was executed for different peak current and duty factor. From this study, the MRR was found to be increased with the peak current. The more MRR was obtained for the case of electrode inside diam-eter of 10 mm, but the MRR was decreased as the diameter near at the 4mm and 6mm. The values of surface roughness and roundness were analyzed under various conditions, and these were affected by the inside diameter change of electrode.

  • PDF

Die-singing Electrical Discharge Machining of Cold Die Alloy Steel with Dielectric Fluid Djection System (방전유 분사시스템에 의한 냉간금형용 합금강의 형조방전가공)

  • 우정윤
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.473-477
    • /
    • 2000
  • The experimental study of die-sinking electrical discharge machining(EDM) was conducted for Cold Die Alloy Steel of SKD-11 with rotary electrode according to the peak current of 11A, 15A and 19A, and the duty factor of 0.24, 0.45. dielectric fluid flow through the electrode inside according to the change of electrode internal diameter during the EDM working. Material removal rate(MRR) was increased with flushing & rotation of electrode at the condition for the peak current of 15A, 19a but the MRR is decreased at the flushing only. The more surface roughness was obtained for the case of the flushing & rotation under the peak current of 19A.

  • PDF

Electrochemical Characteristics of Activated Carbon Electrode for Supercapacitor (Supercapacitor용 활성탄 전극의 전기 화학적 특성)

  • 김경민;이용욱;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.11a
    • /
    • pp.273-277
    • /
    • 2002
  • In the electrode fabrication of unit cell, we found that optimal the electrochemical characteristics were obtained with at 90 wt.% of activated carbon(BP-20), 5 wt.% of conducting agent(Ppy, Super P) and 5 wt.% of P(VdF-co-HFP)/PVP mixed binder. The electrochemical characteristics of unit cell with Ppy improver were as follows : 37.6 F/g of specific capacitance, 0.98 $\Omega$ of AC-ESR, 2.92 Wh/kg and 6.05 Wh/L of energy density, and 754 W/kg and 1,562 W/L of power density. It was confirmed that internal resistance were reduced due to the increase of electrical conductivity and filling density by the introduction of conductivity agent, and content of conducting agent was suitable in the range of 4~6 wt.%. According to the impedance measurement of the electrode with conductivity agent, we found that it was possible to charge rapidly by the fast steady-state current convergence due to low equivalent series resistance(AC-ESR), fast charge transfer rate at interface between electrode and electrolyte, and low RC time constant.

  • PDF

Electrochemical Properties of Electric Double Layer Capacitor with PolyanilineComposite (Polyaniline Composite 전극을 사용한 전기 이중층 캐패시터의 전기화학적 특성)

  • 강광우;김종욱;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.370-373
    • /
    • 1999
  • The purpose of this study is to research and develop PAn composite electrode for EDLC. EDLC cell of PAn composite electrode with 1M LiClO$_4$/PC brings out good capacitor performance below 4.0V. The radius of semicircle of PAn composite electrode adding 15wt% SP270 was absolutely small. The total resistance of EDLC cell mainly depended on internal resistance of the electrode. The discharge capacitance of PAn composite with 15wt% SP270 in 1st and 200th cycles was 42 and 42 F/g at current density of 1mA/cm$^2$. The capacitance of PAn composite with 15wt%. SP270 capacitor was larger than that of PAn capacitor without SP270. The coulombic efficiency of EDLC at discharge process of 1 and 200 cycles were 94 and 100% respectively. PAn composite EDLC with 15wt% SP270 content showed good capacitance and stability with cycling.

  • PDF

PERFORMANCE OF MULTILAYER CERAMIC ACTUATOR BY CONSIDERING THE SHAPE EFFECT

  • Wee, S.B.;Jeong, S.J.;Song, J.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.594-597
    • /
    • 2003
  • In the present study, the piezoelectricity and polarization of multilayer ceramic actuator, being designed to stack PMN-PZ-PT ceramic layers and Ag-Pd electrode layers alternatively, were investigated under a consideration of geometric factor, the volume ratio of the ceramic to the electrode layers. The actuators were fabricated by tape casting of 0.2Pb(Mg1/3Nb2/3)O3-0.38PbZrO3-0.42PbTiO3 followed by lamination and burnout & co-firing processes. The actuators of 10 10 0.62 nm3 in size were formed in a way that 60 200 m thick ceramics were stacked alternatively with 5 m thick electrode layer. Increases in polarization and electric field-induced displacement with thickness of the ceramic layer were attributed to change of 90o/180o domain ratio, which was affected by interlayer internal stress. The piezoelectricity and actuation behaviors were found to depend upon the volume ratio (or thickness ratio) of ceramic to electrode layers.

  • PDF

Identification of Internal Resistance of Microbial Fuel Cell by Electrochemical Technique and Its Effect on Voltage Change and Organic Matter Reduction Associated with Power Management System (전기화학적 기법에 의한 미생물연료전지 내부저항 특성 파악 및 전력관리시스템 연계 전압 변화와 유기물 저감에 미치는 영향)

  • Jang, Jae Kyung;Park, Hyemin;Kim, Taeyoung;Yang, Yoonseok;Yeo, Jeongjin;Kang, Sukwon;Paek, Yee;Kwon, Jin Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.220-228
    • /
    • 2018
  • The internal resistance of microbial fuel cell (MFC) using stainless steel skein for oxidizing electrode was investigated and the factors affecting the voltage generation were identified. We also investigated the effect of power management system (PMS) on the usability for MFC and the removal efficiency of organic pollutants. The performance of a stack microbial fuel cell connected with (PMS) or PMS+LED was analyzed by the voltage generation and organic matter reduction. The maximum power density of the unit cells was found to be $5.82W/m^3$ at $200{\Omega}$. The maximum current density was $47.53A/m^3$ without power overshoot even under $1{\Omega}$. The ohmic resistance ($R_s$) and the charge transfer resistance ($R_{ct}$) of the oxidation electrode using stainless steel skein electrode, were $0.56{\Omega}$ and $0.02{\Omega}$, respectively. However, the sum of internal resistance for reduction electrode using graphite felts loaded Pt/C catalyst was $6.64{\Omega}$. Also, in order to understand the internal resistance, the current interruption method was used by changing the external resistance as $50{\Omega}$, $300{\Omega}$, $5k{\Omega}$. It has been shown that the ohm resistance ($R_s$) decreased with the external resistance. In the case of a series-connected microbial fuel cell, the reversal phenomenon occurred even though two cells having the similar performance. However, the output of the PMS constantly remained for 20 hours even when voltage reversal occurred. Also the removal ability of organic pollutants (SCOD) was not reduced. As a result of this study, it was found that buffering effect for a certain period of time when the voltage reversal occurred during the operation of the microbial fuel cell did not have a serious effect on the energy loss or the operation of the microbial fuel cell.