• Title/Summary/Keyword: internal dissipation

Search Result 120, Processing Time 0.033 seconds

Operational Characteristics of Pulsating Heat Pipes for the Application to the Heat Dissipation of LED Lighting (LED 조명 방열 환경에서 진동형 히트파이프의 작동 특성)

  • Bang, Kwang-Hyun;Kim, Hyoung-Tak;Park, Hae-Kyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.830-836
    • /
    • 2012
  • An efficient cooling system is essential for the electronic packaging such as a high-luminance LED lighting. A special heat transport technology, Pulsating Heat Pipe (PHP), can be applied to the cooling of LED lighting. In this paper, the operational characteristics of the PHP in the imposed thermal boundary conditions of LED lighting were experimentally investigated. The experimental PHP was made of copper tubes of internal diameter of 2.1 mm. The working fluids of ethanol, FC-72, water, acetone and R-123 were chosen for comparison. The results showed that an optimum range of charging ratio exists for high cooling performance; 50% for most of the fluids. Among the five working fluids, water showed the highest heat transfer rate of 260 W. Two distinguished characteristics of pulsating direction were identified. It is also identified that high vapor pressure gradient is one of key parameters for better heat transfer performance.

Bioimpedance Changes in Rats with CCl4-Induced Liver Fibrosis

  • Heo, Jeong;Jung, Dong-Keun
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.71-76
    • /
    • 2011
  • To characterize the relationship between the stage of hepatic fibrosis and bioimpedance, several electric parameters were estimated in rats with $CCl_4$-induced liver fibrosis. Thirty three Sprague-Dawley rats were intraperitoneally injected with a $CCl_4$-mineral oil mixture (1:1, 0.2 mL/100 g) twice a week for 8 weeks. The resistance(R), reactance(X), impedance(Z), and dissipation factor(D) between 1 kHz and 100 kHz were then evaluated in the livers of the rats under pentobarbital anesthesia using an HP4294A Impedance Analyzer. The rats were killed 2, 4, 6, and 8 weeks later, and their livers were classified in accordance with Ishak's scoring system. R, X, and Z changed in accordance with the progression of hepatic fibrosis and the changes were greater at lower frequencies than at higher frequencies. In comparison, the D spectrum was biphasic; D increased initially then decreased with increasing frequency. All of the parameters(R, X, Z, and D) changed in accordance with the stage of fibrosis in the livers, but D changed specifically with the progression of fibrosis. These results indicate that hepatic fibrosis may be evaluated by determining the changes in D.

Predictive Study of Hysteretic Rubber Friction Based on Multiscale Analysis (멀티스케일 해석을 통한 히스테리시스 고무 마찰 예측 연구)

  • Nam, Seungkuk;Oh, Yumrak;Jeon, Seonghee
    • Tribology and Lubricants
    • /
    • v.30 no.6
    • /
    • pp.378-383
    • /
    • 2014
  • This study predicts the of the hysteretic friction of a rubber block sliding on an SMA asphalt road. The friction of filled rubber on a rough surface is primarily determined by two elements:the viscoelasticity of the rubber and the multi-scale perspective asperities of the road. The surface asperities of the substrate exert osillating forces on the rubber surface leading to energy dissipation via the internal friction of the rubber when rubber slides on a hard and rough substrate. This study defines the power spectra at different length scales by using a high-resolution surface profilometer, and uses rubber and road surface samples to conduct friction tests. I consider in detail the case when the substrate surface has a self affine fractal structure. The theory developed by Persson is applied to describe these tests through comparison with the hysteretic friction coefficient relevant to the energy dissipation of the viscoelastic rubber attributable to cyclic deformation. The results showed differences in the absolute values of predicted and measured friction, but with high correlation between these values. Hence, the friction prediction model is an appropriate tool for separating the effects of each factor. Therefore, this model will contribute to clearer understanding of the fundamental principles of rubber friction.

Experimental Study of the Seismic Performance of CJS Hybrid Structural Systems Connected to the CFT Column (CFT와 합성보로 이루어진 CJS합성구조시스템의 내진성능 실험 연구)

  • Lim, Chang Gue;Shin, Jiuk;Moon, A Hae;Kim, Yong Nam;Lee, Kihak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.83-93
    • /
    • 2022
  • In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems' joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.

Mechanism of Consolidation Displacement on Internal Behavior of Clay Ground Improved by Sand Drain (샌드 드레인으로 개량된 점토지반의 내부거동에 대한 압밀변형 메커니즘)

  • Baek, Won-Jin
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.6
    • /
    • pp.69-77
    • /
    • 2006
  • In this study, the large scaled model test improved by sand drain was carried out to clarify the internal behavior of the three-dimensional consolidation under different secondary consolidation periods. From the results of model test, the void ratio in the undrained side was lager than in the drained side. In addition, the unconfined compressive strength in the long-term consolidated specimen was larger than that in the short-term consolidated one. It was also found that the unconfined compressive strength was larger in the drained side than in the undrained side. These reasons are considered to be due to the large effective stress by quick pore water pressure dissipation by the short drainage distance in the drained side. Furthermore, in order to investigate the three-dimensional consolidation behavior of clay ground improved by the vertical drain method, the numerical analysis obtained from the three-dimensional elasto-viscous consolidation theory proposed by author (2006) were compared with the test results. It was found that during the three-dimensional consolidation process not only vertical displacement but also radial displacement occurs inside the specimen.

Administration Progression and Adverse Event Report of Er-Xian Decoction for Menopausal Hot Flushes: Case Report and Review of Literature (폐경기 안면홍조 증상에 대한 한약처방 이선탕의 투여경과 및 이상반응 보고 : 증례보고 및 문헌고찰)

  • Kim, Bo-min;Jo, Hee-geun
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.1
    • /
    • pp.154-163
    • /
    • 2019
  • Objective: We report on the administration progression and adverse event of Er-Xian decoction for menopausal hot flushes. A hot flush is a rapid and intense heat-dissipation reaction that involves considerable sweating, enlargement of the peripheral blood vessels, and internal body heat. Er-Xian decoction is a prescription for treating menopausal hot flush symptoms in postmenopausal women. We report administration progression and adverse event of Er-Xian decoction for menopausal hot flush. Methods: We used the Menopause Rating Scale and Menopause-Specific Quality of Life questionnaire to evaluate the progression of hot flushes, and we conducted a literature review to determine the effective dosage of Er-Xian decoction. Result: In all cases, Facial hot flushes and evaluation variables were improved by the administration of EXD. However, in Case 1, a rise of liver function indexes which may be related to EXD administration was observed. Conclusion: Considering that menopausal flushing usually lasts for several years, The resluts are meaningful that the short-term administration of EXD led to improvement of symptoms. In order to further use EXD in the future, it will be necessary to conduct follow-up studies on the subject of safety verification, such as repeated dose toxicity studies.

Tracheobronchial Polyps Following Thermal Inhalation Injury

  • Shin, Beomsu;Kim, Mikyeong;Yoo, Hongseok;Kim, Se Jin;Lee, Ji Eun;Jeon, Kyeongman
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.5
    • /
    • pp.237-239
    • /
    • 2014
  • The early pulmonary consequences of inhalation injury are well documented; however, little is known about delayed pulmonary complications following thermal inhalation injury. Although thermal injury below the vocal cords is rare because of effective heat dissipation in the upper airway, inflammatory endobronchial polyps have previously been reported as a delayed complication associated with inhalation injury. We report an extraordinary case of tracheobronchial polyps in patients with smoke inhalation injury. This report shows the delayed development and natural course of tracheobronchial polyps following thermal injury.

A 3.3V/5V Low Power TTL-to-CMOS Input Buffer Controlled by Internal Activation Clock Pulse (활성 클럭펄스로 제어되는 3.3V/5V 저전력 TTL-to-CMOS 입력 버퍼)

  • Bae, Hyo-Kwan;Ryu, Beom-Seon;Cho, Tae-Won
    • Journal of IKEEE
    • /
    • v.5 no.1 s.8
    • /
    • pp.52-58
    • /
    • 2001
  • This paper describes a TTL-to-CMOS input buffer of an SRAM which dissipates a small operating power dissipation. The input buffer utilizes a transistor structure with latch circuit controlled by a internal activation clock pulse. During the low state of that pulse, input buffer is disabled to eliminate dc current. Otherwise, the input buffer operates normally. Simulation results showed that the power-delay product of the purposed input buffer is reduced by 33.7% per one input.

  • PDF

Experimental characterization of timber framed masonry walls cyclic behaviour

  • Goncalves, Ana Maria;Ferreira, Joao Gomes;Guerreiro, Luis;Branco, Fernando
    • Structural Engineering and Mechanics
    • /
    • v.53 no.2
    • /
    • pp.189-204
    • /
    • 2015
  • After the large destruction of Lisbon due to the 1755 earthquake, the city had to be almost completely rebuilt. In this context, an innovative structural solution was implemented in new buildings, comprising internal timber framed walls which, together with the floors timber elements, constituted a 3-D framing system, known as "cage", providing resistance and deformation capacity for seismic loading. The internal timber framed masonry walls, in elevated floors, are constituted by a timber frame with vertical and horizontal elements, braced with diagonal elements, known as Saint Andrew's crosses, with masonry infill. This paper describes an experimental campaign to assess the in-plane cyclic behaviour of those so called "frontal" walls. A total series of 4 tests were conducted in 4 real size walls. Two models consist of the simple timber frames without masonry infill, and the other two specimens have identical timber frames but present masonry infill. Experimental characterization of the in-plane behaviour was carried out by static cyclic shear testing with controlled displacements. The loading protocol used was the CUREE for ordinary ground motions. The hysteretic behaviour main parameters of such walls subjected to cyclic loading were computed namely the initial stiffness, ductility and energy dissipation capacity.

Heat Dissipation of Cylinder Head of Reciprocating Internal Combustion Engine (왕복동 내연기관 실린더 헤등의 방열에 관한 연구)

  • Kim, K. C.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.1
    • /
    • pp.71-78
    • /
    • 1984
  • 본 논문은 왕복동 내연기관의 방열에 관한 연구의 하나로서 디이젤 기관 실린더 헤드와 흡 배기 밸브의 온도 분포와 열유속의 분포를 구한 것이다. 방열 해석은 기관의 정상 작동된 다음의 실린 더 헤드의 열부하가 일정하다고 생각하여 실린더 헤드의 밸드 시이트 양단의 온도와 연소 가스 배출 온도, 흡기 및 냉각수 온도를 측정하고 온도분포 및 열유속을 유한요소법을 적용하여 구하 였다. 본 연구의 결과 실린더 헤드 및 밸브의 과부하는 밸브의 경우에는 밸브 헤드 중심과 밸브 헤드 중심 부근에서 일어나며, 실린더 헤드의 경우에는 헤드 중심부 표면에서 발생하였다. 흡 배 기 밸브 및 물재킷부의 온도 분포 및 열유속의 분포를 주어진 냉각수 온도 조건에 대하여 구한 후 이들을 비교 검토 하였다.