• Title/Summary/Keyword: internal diaphragm

Search Result 89, Processing Time 0.022 seconds

Rare Manifestation of the Cutaneous and Cervical Lymph Node Metastases of Urothelial Carcinoma of Urinary Bladder: A Case Report (방광요로상피암에서 드물게 나타나는 피부와 목 림프절로의 전이: 증례 보고)

  • Woo Yeol Sim;Noh Hyuck Park;Yoon Yang Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1403-1407
    • /
    • 2023
  • Lymph node metastasis from bladder cancer mainly involves the external/internal iliac and obturator nodes as the primary lymphatic drainage sites of the bladder, and common iliac sites as the secondary drainage. Lymph node involvement above the diaphragm is rare. Metastasis to the head and neck region is associated with poor prognosis and low survival rate. Herein, we report a case of cervical cutaneous and lymph node metastases in a patient with bladder cancer. This is a rare case of advanced urothelial carcinoma presenting as an aggressive inflammatory process with extensive lymph node involvement, without bony or visceral metastasis.

A Study on the elastic properties of coated layers and the changes of microstructure in plasma spray coating of $Al_2$O$_3$-TiO$_2$ ceramics (Al$_2$O$_3$-TiO$_2$세라믹의 플라즈마 용사과정에서 미세구조의 변화와 용사코팅층의 탄성에 대한 연구)

  • 이형근;김대훈;황선효;안병국;김병희;서동수;안명구
    • Journal of Welding and Joining
    • /
    • v.14 no.6
    • /
    • pp.109-118
    • /
    • 1996
  • Al$_2$O$_3$-TiO$_2$powders of six different compositions were plasma-sprayed on Ti substrate. The spray powders and the spray coated layers were analysed and compared using SEM and X-RD. The elastic properties (specific elastic constant and damping coefficient) of the coated specimens were measured in order to select the optimum composition range of ceramics for use in a speaker diaphragm. A correlation between the microstructure and elastic properties was also investigated. When $Al_2$O$_3$powders with 0- 13% TiO$_2$were plasma sprayed, the coated layers were composed of metastable y-Al$_2$O$_3$with small amount of $\alpha$-Al$_2$O$_3$and the content of $\alpha$-Al$_2$O$_3$was increased with TiO$_2$content. Specific elastic constant was rapidly increased with 2 and 13% TiO$_2$addition to $Al_2$O$_3$. The internal damping was nearly unchanged with TiO$_2$content The specific elastic constant seemed to be dependent on the content of $\alpha$-Al$_2$O$_3$in the coated layer.

  • PDF

Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock (전철 탑재형 피뢰기의 모듈설계 및 성능평가기술)

  • Cho, H.G.;Kim, S.S.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

Design and Performance Evaluation of Surge Arrester for Loading in Railway Rolling Stock (전철 탑재용 피뢰기의 설계 및 성능평가)

  • Cho, H.G.;Han, S.W.;Lee, U.Y.;Kim, S.S.;Chang, T.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.74-77
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock. pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

Optimization of construction support scheme for foundation pits at zero distance to both sides of existing stations based on the pit corner effect

  • Tonghua Ling;Xing Wu;Fu Huang;Jian Xiao;Yiwei Sun;Wei Feng
    • Geomechanics and Engineering
    • /
    • v.38 no.4
    • /
    • pp.381-395
    • /
    • 2024
  • With the wide application of urban subway tunnels, the foundation pits of new stations and existing subway tunnels are becoming increasingly close, and even zero-distance close-fitting construction has taken place. To optimize the construction support scheme, the existing tunnel's vertical displacement is theoretically analyzed using the two-stage analysis method to understand the action mechanism of the construction of zero-distance deep large foundation pits on both sides of the existing stations; a three-dimensional numerical calculation is also performed for further analysis. First, the additional stress field on the existing tunnel caused by the unloading of zero-distance foundation pits on both sides of the tunnel is derived based on the Mindlin stress solution of a semi-infinite elastic body under internal load. Then, considering the existing subway tunnel's joints, shear stiffness, and shear soil deformation effect, the tunnel is regarded as a Timoshenko beam placed on the Kerr foundation; a sixth-order differential control equation of the tunnel under the action of additional stress is subsequently established for solving the vertical displacement of the tunnel. These theoretical calculation results are then compared with the numerical simulation results and monitoring data. Finally, an optimized foundation pit support scheme is obtained considering the pit corner effect and external corner failure mode. The research shows a high consistency between the monitoring data,analytical and numerical solution, and the closer the tunnel is to the foundation pit, the more uplift deformation will occur. The internal corner of the foundation pit can restrain the deformation of the tunnel and the retaining structure, while the external corner can cause local stress concentration on the diaphragm wall. The proposed optimization scheme can effectively reduce construction costs while meeting the safety requirements of foundation pit support structures.

Double-Chambered Right Ventricle in an Old Standard Poodle Dog

  • Yunho Jeong;Yoonhwan Kim;Eunchan Lee;Ju-Hyun An;Sooyoung Choi;Jin-Young Chung;Jin-Ok Ahn
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.130-134
    • /
    • 2023
  • A 12-year-old Standard Poodle presented with intermittent weakness and occasional dyspnea at the Veterinary Medicine Teaching Hospital of Kangwon National University. A grade of 4 out of 6 systolic murmur with an irregular tachycardic rhythm was auscultated on both sides of the chest. Systolic blood pressure was 140 mmHg. Panting was noticed in the hospital, but there was no crackle sound. Blood analysis revealed mild increases in liver panel levels (alanine aminotransferase 149 [reference interval, 19-70] U/L; and alkaline phosphatase, 185 [reference interval, 15-127] U/L) and severe increases in cardiac biomarker levels (n-terminal pro-brain natriuretic peptide, 4169 [reference interval, 50-900] pmol/L; and cardiac troponin I, 0.22 [reference interval, 0.03-0.12] ng/mL). On electrocardiography, irregularly irregular supraventricular tachycardic rhythm with an f-wave and no distinct p-wave was observed. Generalized cardiomegaly with an enlarged right atrium and left ventricle was confirmed on thoracic radiography. Moreover, hepatomegaly and an enlarged caudal vena cava were observed. Echocardiographic evaluation revealed a fibromuscular diaphragm in the right ventricle. Because of the obstructive lesion in the right ventricle, the right atrium and ventricle were enlarged (right atrial area index, 38.82 cm2/m2 [reference interval, 4.2-10.2 cm2/m2]; right ventricle end-diastolic area index, 14.152 cm2/m2 [reference interval, 4.9-10.92 cm2/m2]). Accordingly, the patient was diagnosed with double-chambered right ventricle (DCRV). Pimobendan, furosemide, enalapril, diltiazem, and S-adenosylmethionine (SAMe) were prescribed, and all symptoms were relieved. DCRV is a right-sided congenital heart defect resembling pulmonic valve stenosis. If symptoms are not severe, medical therapy can be facilitated without surgery or the balloon dilation.

Development of Respiratory Motion Reduction Device System (RMRDs) for Radiotherapy in Moving Tumor: Construction of RMRDs and Patient Setup Verification Program

  • Lee, Suk;Chu, Sung-Sil;Lee, Sei-Byung;Jino Bak;Cho, Kwang-Hwan;Kwon, Soo-Il;Jinsil Seong;Lee, Chang-Geol;Suh, Chang-Ok
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.86-89
    • /
    • 2002
  • The purpose is to develop a system to reduce the organ movement from the respiration during the 3DCRT or IMRT. This research reports the experience of utilizing personally developed system for mobile tumors. The patients clinical database was structured for 10 mobile tumors and patient setup error measurement and immobilization device effects were investigated. The RMRD system is composed of the respiratory motion reduction device utilized in prone position and abdominal strip device(ASD) utilized in the supine position, and the analysis program, which enables the analysis on patients setup reproducibility. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the normal tissue volume, field margins and dose volume histogram(DVH) using fluoroscopy and CT images. And, reproducibility of patients setup verify by utilization of digital images. When patients breathed freely, average movement of diaphragm was 1.2 cm in prone position in contrast to 1.6 cm in supine position. In prone position, difference in diaphragm movement with and without RMRDs was 0.5 cm and 1.2 cm, respectively, showing that PTV margins could be reduced to as much as 0.7 cm. With RMRDs, volume of the irradiated normal tissue (lung, liver) reduced up to 20 % in DVH analysis. Also by obtaining the digital image, reproducibility of patients setup verify by visualization using the real-time image acquisition, leading to practical utilization of our software. Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Effect of Trunk Strength Exercise and Deep Stabilization Exercise Combined with Breathing Exercise on Abdominal Muscle Thickness and Respiration (호흡운동을 병행한 몸통 근력운동과 심부 안정화 운동이 배근육 두께와 호흡에 미치는 영향)

  • Kim, Hyeonsu;Lee, Keoncheol;Choo, Yeonki
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.181-188
    • /
    • 2020
  • Purpose : The purpose of this study is to compare the effects on abdominal muscle thickness and breathing by applying trunk strength exercise and deep stabilization exercise along with breathing exercise, which is the main respiratory muscle during breathing, to present an efficient exercise method with diaphragm breathing. Methods : This study was performed on normal 6 females and 14 males subjects. They were divided into 2 groups which trunk strength exercise and deep stabilization exercise group. The trunk strength exercise group (TSE) attended prone press-up, crunch and pelvic tiling. The deep stabilization exercise group (DSE) attended abdominal drawing, horizontal side-support and bridging exercise. Breathing exercise was performed for each set break time for 1 minute. Results : First, in the comparison of the change in the thickness of the abdominal muscle between the trunk strength training group and the deep stabilization group before and after exercise, there was a statistically significant difference in the comparison of transverse abdominis (TrA), rectus femoris (RF), external oblique (EO), internal oblique (IO) (p<.05). However, there was no significant difference in any comparison between groups (p>.05). Second, in the comparison of changes in respiratory function between the trunk strength exercise group and the deep stabilization exercise group before and after exercise, there were statistically significant differences in the exerted forced vital capacity (FVC), forced expiratory volume at one second (FEV1), peak expiratory flow (PEF) in the comparison before and after the experiment (p<.05). However, there was no significant difference in any comparison between groups (p>.05). Conclusion : As a result of this study, it can be said that both trunk strength exercises and deep stabilization exercises along with diaphragm breathing are exercises that strengthen deep and superficial muscles, and have a positive effect on breathing function as well as muscle strength. However, it is not known which exercise was more effective, and because it was combined with breathing exercise, the interference effect appeared.

The Optimum of Respiratory Phase Using the Motion Range of the Diaphragm: Focus on Respiratory Gated Radiotherapy of Lung Cancer (횡격막의 움직임을 이용한 최적화된 호흡 위상의 선택: 폐암의 호흡 동기 방사선치료 중심)

  • Kim, Myoungju;Im, Inchul;Lee, Jaeseung;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.157-163
    • /
    • 2013
  • This study was to analyze quantitatively movement of planning target volume (PTV) and change of PTV volume through movement of diaphragm according to breathing phase. The purpose of present study was to investigate optimized respiration phase for radiation therapy of lung cancer. Simulated breathing training was performed in order to minimize systematic errors which is caused non-specific or irregular breathing. We performed 4-dimensional computed tomography (4DCTi) in accordance with each respiratory phase in the normalized respiratory gated radiation therapy procedures, then not only defined PTVi in 0 ~ 90%, 30 ~ 70% and 40 ~ 60% in the reconstructed 4DCTi images but analyzed quantitatively movement and changes of volume in PTVi. As a results, average respiratory cycle was $3.4{\pm}0.5$ seconds by simulated breathing training. R2-value which is expressed as concordance between clinically induced expected value and actual measured value, was almost 1. There was a statistically significant. And also movement of PTVi according to each respiration phase 0 ~ 90%, 30 ~ 70% and 40 ~ 60% were $13.4{\pm}6.4mm$, $6.1{\pm}2.9mm$ and $4.0{\pm}2.1mm$ respectively. Change of volume in PTVi of respiration phase 30 ~ 70% was decreased by $32.6{\pm}8.7%$ and 40 ~ 60% was decreased by $41.6{\pm}6.2%$. In conclusion, PTVi movement and volume change was reduced, when we apply a short breathing phase (40 ~ 60%: 30% duty cycle) range. Furthermore, PTVi margin considered respiration was not only within 4mm but able to get uniformity of dose.

Laparotomy versus Laparoscopic Placement of Distal, Catheter in Ventriculoperitoneal Shunt Procedure

  • Park, Young-Seop;Park, In-Sung;Park, Kyung-Bum;Lee, Chul-Hee;Hwang, Soo-Hyun;Han, Jong-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.4
    • /
    • pp.325-329
    • /
    • 2010
  • Objective : Traditionally, peritoneal catheter is inserted with midline laparotomy incision in ventriculoperitoneal (V-P) shunt procedures. Complications of V-P shunt is not uncommon and have been reported to occur in 5-37% of cases. The aim of this study is to compare the clinical outcomes and the operation time between laparotomy and laparoscopic groups. Methods : A total of 155 V-P shunt procedures were performed to treat hydrocephalic patients of various origins in our institute between June 2006 to January 2010; 95 of which were laparoscopically guided and 65 were not. We reviewed the operation time, surgery-related complications, and intraoperative and postoperative problems. Results : In the laparoscopy group, the mean duration of the procedure (52 minutes) was significantly shorter (p < 0.001) than the laparotomy group (109 minutes). There were two cases of malfunctions and one incidence of diaphragm injury in the laparotomy group. In contrast, there were neither malfunction nor any internal organ injuries in the laparoscopy group (p = 0.034). There were total of two cases of infections from both groups (p = 0.7). Conclusion : Laparoscopically guided insertions of distal shunt catheter is considered a fast and safe method in contrast to the laparotomy technique. This method allows the exact localization of the peritoneal catheter and a confirmation of its patency.