• Title/Summary/Keyword: intermittent operation

Search Result 176, Processing Time 0.027 seconds

A High Voltage Poorer Supply for Electrostatic Precipitator with Superimposing Voltage Pulse on DC Source (펄스 및 직류 중첩형 전기집진기용 고전압 전원장치 개발 연구)

  • Kim, Jong-Soo;Rim, Geun-Hie;Lee, Sung-Jin;Kim, Seung-Min;Cho, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.624-630
    • /
    • 2001
  • The trend of the regulations on environmental issues are getting tight. Responding to this trend new technologies such as moving electrodes, wide pitch and pulsed power supply are also introduced in the electrostatic precipitator(EP) systems. The introduction of wide pitch and moving electrodes enhances the system performance of the EPs by improving air-flow and by improving the ash reentrainment on rapping. The power supplies for the EPs developed up to date include thyristor-based dc or intermittent type, SMPS(switching mode power supply) type and the pulsed-power supply type. The use of the pulsed ones is known to improve dust-collecting efficiency of high resistivity ash and reduces back corona occurrence in the collecting plate. There are two kinds of pulsed-power supplies; one with pulsed transformers and the other with direct dc switching devices. The latter uses rotary spark gap switches or semiconductor switches. Both have the merits and demerits: the spark gap switches are simple and robust but has short life time, hence, high maintenance cost, whereas the semiconductor switches have long life time but are costly. In this study, A high voltage power supply with superimposing voltage pulse on dc source was developed for EPs. This study describes circuit topology, operating principle of the scheme, and analysis of experimental results on Dong-Hae Power Plant. The pulsed power supply consists of a variable dc power supply with ratings of 60kV, 800mA and pulse generator which is made of high voltage thyristor-diode switch strings, an LC resonant tank and a blocking inductor. The pulse generator generates variable pulse-voltage up to 70kV using a high frequency resonant inverter with a variable dc source. Two prototypes were built and tested on 250MW DongHae power plant to verify the possibility of the commercial use and the normal operation in the transient states.

  • PDF

Aorto-Coronary Bypass Graft -A Case Report- (관상동맥 회로술 치험 1예)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.297-305
    • /
    • 1979
  • Occlusive coronary artery disease presents a potential threat to a significant population in the United States. According to many case reports, the increasing incidence of coronary artery disease due to atherosclerosis is noted in Korean, recently. Operative vascular procedures have increased steadily in number over the past 20 years in the United States. There have been many isolated case reports about coronary artery surgery, but these had little clinical impact. Nowadays, major three coronary bypass surgery has developed principally at three cardiac centers in the United States since 1967. Among three coronary bypass operation, the aorta-coronary artery saphenous vein bypass graft was first demonstrated by Favolaro and Effler at the Cleveland Clinic in 1967. We experienced one case of coronary artery disease, which was treated successfully by aorta-coronary saphenous vein graft with mild hypothermia under extracorporeal circulation in May, 1977. Saphenous vein was removed from above the knee and was 2.5 mm in diameter. The left ventricle was not vented for the left ventricle was not overdistended. Temporary artificial pace-maker-Medtronic-was implanted for the prevention and treatment of post-operative arrhythmia and heart block in post-operative first day. He is a 57 year old male businessman who had been suffered from hypertension [200 mmHg in systolic pressure] since 4 years ago, who had intermittent conservative treatment at local clinic. He had been afflicted with severe chest pain with choking sensation for 50 days. This symptom was aggravated exposing cold weather, or cold water, but was respond to rest. Pre-operative ECG revealed no any other ischemic sign except sinus bradycardia. Significant S-T segment depression was noted at lead II, AVF after double 5 minutes exercise, indicating positive Master`s test. Serum cholesterol was slight elevated to 253 mg/dl. Final pre-operative diagnosis was made by coronary arteriogram, which showed about 1.0-cm segmental 90 % occlusive atherosclerotic lesion in the proximal part of right coronary artery above the origin of acute marginal artery. Left coronary artery revealed good patency and there was no collateral circulation between right and left coronary artery .Hospital course was not eventful. He was discharged with good result on the post-operative day. He has been free from chest pain for longer than 2 years. And also the arterial flow in the coronary bypass graft is auscultated with the pocket-sized ultrasonic velocity detector, which shows the patency of the coronary bypass graft good.

  • PDF

Atypical Aortic Coarctation at the Level of Aortic Hiatus: Report of a case treated by bypass graft (대동맥 열공부에 발생한 비전형적 대동맥 협착증: 외과적 수술을 가한 1례)

  • 남민우;유회성;지정희
    • Journal of Chest Surgery
    • /
    • v.5 no.1
    • /
    • pp.13-18
    • /
    • 1972
  • In 1835,Schlesinger first described a case of subisthmlc lower thoracic aortic coarctation. Since Olim`s unsuccessful reconstructive surgery in 1949 and Beattie`s first successful resection with homograft replacement on such a lesion in 1951 were reported,about 20 cases of atypical aortic coarctation had been treated by definitive surgery until 1964. In Korea, only 2 cases of atypical aortic coarctation treated by bypass graft were reported until now. This is the third case-report treated by reconstructive surgery. The patient,11 year old girl who had 2 year history of headache, visual weakness, intermittent claudlcation, and general weakness, was first diagnosed of having the hypertension due to atypical coarctation by the findings of high blood pressure[170/110mmHg] at the upper extremity and weak pulsation on both femoral artery,murmur on the epigastrium, absence of aortic knob, and aorto graphy. Aortography demonstrated the isolated segmental narrowing[length 5cm, diameter 0.4cm] at the level of aortic hiatus 2cm above celiac arterial origin, the dilated right 9th, 10th, 11th intercostal arteries with multiple dimunitive collaterals and no associated abnormalities in the other arteries. Preoperatlve positive findings were strong positive mantoux test, high AST[720 units]. transient mild cardiomegaly with right lung infiltration on chest X-ray and suggestive left ventricular hypertrophy on ECG. On December 1970, through separate left thoracotomy and abdominal approach, bypass graft between descending thoracic aorta and abdominal aorta below renal artery was performed. The operation was first successful with satisfactory reduction of hypertension on the upper trunk[postoperatlve 130/80mmHg] and strong pulsation on the lower extremities[postop. O, postop. 140/100mmHg]. However,6 weeks after surgery, she expired of sudden hemoptysis and shock due to anastomotic leak within the thorax. Operative finding disclosed that the affected aorta was firm, with rich periaortic fibrosis and the outer diameter of stenotic site was not attenuated. Histopathology of the resected specimen was also compatible with primary arteritis.

  • PDF

Laparoscopic Operation for Superior Mesenteric Artery Syndrome and Follow-up with 3-Dimensional Reconstructive CT - 1 Case Report - (상장간막동맥 증후군의 복강경 수술 및 3차원재건 복부 전산화단층촬영 영상을 이용한 추적관찰 -1예보고-)

  • Kim, Seong-Min;Kim, Sung-Hoon;Kwon, In-Kyou;Kim, Myoung-Joon;Hyoung, Woo-Jin;Choi, Seung-Hoon
    • Advances in pediatric surgery
    • /
    • v.11 no.2
    • /
    • pp.180-185
    • /
    • 2005
  • Superior mesenteric artery (SMA) syndrome is a rare disorder caused by extrinsic compression of the third portion of the duodenum by the SMA. The operative treatment of choice is bypassing the obstructed duodenal segment by duodenojejunostomy. We report one case of SMA syndrome treated by laparoscopic duodenojejunostomy and followed up by 3D-reconstructive CT scan. A fifteen-year-old boy with intermittent vomiting and weight loss was admitted. Ultrasonography showed narrowing of the distance between the SMA and aorta. Hypotonic duodenography showed dilatation of duodenal third portion and barium stasis. On 3Dreconstructive CT scan, the angle between SMA and aorta was $37^{\circ}$. The postoperative course was uneventful. Three months later, he had gained 3 kg of weight and the angle between SMA and aorta increased to $38-39^{\circ}$ on 3D reconstructive CT scan. Laparoscopic duodenojejunostomy for bypassing the obstructive duodenum in SMA syndrome is a feasible and safe method.

  • PDF

A Study on the Method to Evaluate Minimum Capacity of Energy Storage System(ESS) for Micro Grid(MG) Design (확률론적 방법론을 이용한 마이크로그리드(MG)의 에너지 저장장치(ESS) 최소 필요용량 및 투자시점 결정방법)

  • Lee, Jae-Gul;Shin, Jeong-Hoon;Nam, Su-Chul;Baek, Sung-Muk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.40-47
    • /
    • 2010
  • In this paper, we propose a probability method to determine minimum capacity of energy storage system(ESS) for Micro Grid(MG). Because of high capital cost of ESS, it's very important to determine optimal capacity of ESS and for stable operation of MG and we should determine minimum capacity of ESS. The proposed method has abilities to consider forced outage rate of generators and intermittent of non-dispatchable generators and minimum capacity make MG keep energy balancing by oneself.

Optimization of Nitrogen and Phosphorus Removal of Temporal and Spatial Isolation Process by Model Simulation System (시공간 동시분할 공정 시뮬레이션을 통한 질소 및 인 제거 최적화 방안)

  • Ryu, Dongjin;Chang, Duk;Shin, Hyungsoo;Park, Sangmin;Hong, Kiho;Kim, Sooyoung;Kim, Myoungjun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.206-215
    • /
    • 2007
  • The objective of this study was to establish the optimal system operating strategies for nitrogen and phosphorus removal through model simulation system built for advanced wastewater treatment targeting on simultaneous temporal/special phase isolation BNR process. The simulation system was built with unit process modules using object modules in GPS-X code. The system was well verified by field experiment data. Simulation study was carried out to investigate performance response to design and operation parameters, i.e. hydraulic retention time (HRT), solids retention time (SRT), and cycle time. The process operated at HRTs of 10~15 hours, longer SRTs, and cycle time of 2 hours showed optimal removal of nitrogen. The HRTs of 10~15 hours, SRTs of 20~25 days, and longer cycle time was optimal for phosphorus removal. Both simulation and field studies showed that optimal operating strategies satisfying both the best nitrogen and phosphorus removals include HRTs ranged 10~15 hours, SRTs ranged 20~25 days, and cycle times of 4~8 hours. The simulation system with modularization of generalized components in BNR processes was, therefore, believed to be a powerful tool for establishing optimal strategies of advanced wastewater treatment.

Smart Anti-jamming Mobile Communication for Cloud and Edge-Aided UAV Network

  • Li, Zhiwei;Lu, Yu;Wang, Zengguang;Qiao, Wenxin;Zhao, Donghao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.12
    • /
    • pp.4682-4705
    • /
    • 2020
  • The Unmanned Aerial Vehicles (UAV) networks consisting of low-cost UAVs are very vulnerable to smart jammers that can choose their jamming policies based on the ongoing communication policies accordingly. In this article, we propose a novel cloud and edge-aided mobile communication scheme for low-cost UAV network against smart jamming. The challenge of this problem is to design a communication scheme that not only meets the requirements of defending against smart jamming attack, but also can be deployed on low-cost UAV platforms. In addition, related studies neglect the problem of decision-making algorithm failure caused by intermittent ground-to-air communication. In this scheme, we use the policy network deployed on the cloud and edge servers to generate an emergency policy tables, and regularly update the generated policy table to the UAVs to solve the decision-making problem when communications are interrupted. In the operation of this communication scheme, UAVs need to offload massive computing tasks to the cloud or the edge servers. In order to prevent these computing tasks from being offloaded to a single computing resource, we deployed a lightweight game algorithm to ensure that the three types of computing resources, namely local, edge and cloud, can maximize their effectiveness. The simulation results show that our communication scheme has only a small decrease in the SINR of UAVs network in the case of momentary communication interruption, and the SINR performance of our algorithm is higher than that of the original Q-learning algorithm.

Mobile Device NDF(No Defect Found) Cost Estimation (모바일 디바이스의 원인불명고장에 관한 비용 추정)

  • Lee, Jewang;Lee, Jungwoo;Han, Chang Hee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.2
    • /
    • pp.102-114
    • /
    • 2021
  • NDF (No Defect Found) is a phenomenon in which defects have been found in the manufacturing, operation and use of a product or facility, but phenomenon of defects is not reproduced in the subsequent investigation system or the cause of the defects cannot be identified. Recently, with the development of the fourth industrial revolution, convergence of hardware and software technologies in various fields is spreading to products such as aircraft, home appliances, and mobile devices, and the number of parts is increasing due to functional convergence. The application of such convergence technologies and the increase in the number of parts are major factors that lead to an increase in NDF phenomena. NDF phenomena have a significant negative impact on cost, reliability, and reliability for both manufacturers, service providers and operators. On the other hand, due to the nature of NDF phenomena such as difficult and intermittent cause identification and ambiguity in judgment, it is common to underestimate the cost of NDF or fail to take appropriate countermeasures in corporate management. Therefore, in this paper, we propose a methodology for estimating NDF costs by the PAF model which is a quality cost analysis model and ABC (Activity Based Costing) technique. The methodology of this study suggests a detailed procedure and the concept to accurately estimate the NDF costs, using ABC analysis, accounting system information, and IT system data. In addition case studies have validated the methodology. We think this could be a valid methodology to refer to when estimating the cost of other parts. And, it is meaningful to provide important judgment information in the decision-making process based on quality management and ultimately reduce NDF costs by visualizing them separately by major variable factors.

Study on Thermal Performance of Energy Textile in Tunnel (터널 지열 활용을 위한 에너지 텍스타일의 열교환 성능 연구)

  • Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1907-1914
    • /
    • 2013
  • Textile-type heat exchangers installed on the tunnel walls for facilitating ground source heat pump systems, so called "energy textile", was installed in an abandoned railroad tunnel around Seocheon, South Korea. To evaluate thermal performance of the energy textile, a series of long-term monitoring was performed by artificially applying daily intermittent cooling and heating loads on the energy textile. In the course of the experimental measurement, the inlet and outlet fluid temperatures of the energy textile, pumping rate, temperature distribution in the ground, and air temperature inside the tunnel were continuously measured. From the long-term monitoring, the heat exchange rate was recorded as in the range of 57.6~143.5 W per one unit of the energy textile during heating operation and 362.3~558.4 W per one unit during cooling operation. In addition, the heat exchange rate of energy textile was highly sensitive to a change in air temperature inside the tunnel. The field measurements were verified by a 3D computational fluid dynamics analysis (FLUENT) with the consideration of air temperature variation inside the tunnel. The verified numerical model was used to evaluate parametrically the effect of drainage layer in the energy textile.

The Importance of Septoplasty in The Treatment of Nasal Bone and Grade I Septal Fracture: Estimation with Acoustic Rhinometry (비중격 골절을 동반한 단순 비골 골절의 치료에 있어 비중격 교정술의 중요성: 비강 통기도 검사를 이용한 평가)

  • Kim, Jun-Hyung;Shin, Dong-Woo;Choi, Tae-Hyun;Son, Dae-Gu;Han, Ki-Hwan
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.626-632
    • /
    • 2010
  • Purpose: Nasal bone fractures are often classified as minor injury. However, the incidence of posttraumatic nasal deformity remains alarmingly high. It is because of unnoticed septal fracture. This study was conducted to determine the necessity of septoplasty for patients with nasal bone fracture accompanying grade I septal fractures. Methods: Among 105 patients with nasal bone fractures, 52 who had grade I septal fracture were diagnosed based on physical examination and computed tomography. Patients' age ranged from 14 to 65 years (mean 29.25 years), and 35 were male and 17 female. Patients were divided into 2 groups according to surgical treatment methods: patients who underwent closed reduction only (group 1, n=28) and those who underwent simultaneous closed reduction and septoplasty (group 2, n=24). The treatment outcomes were evaluated by comparing changes in nasal airway volume measured by acoustic rhinometry before the surgery, 3 months and 6 months after the surgery according to the timing of surgical repair and surgical treatment methods. Results: Nasal airway volume increased after the surgery by 17.8% in 3 months after the surgery, 25.2% in 6 months in group 1 and by 22.7% in 3 months, 35.8% in 6 months in group 2. The increase in airway volume after the surgery by 26.3% in 3 months after the surgery, 34.2% in 6 months after the surgery in operation within 1 week after trauma and by 12.1% in 3 months, 22.2% in 6 months after the operation later 1 week after trauma. The difference was statistically significant. Three patients in group 1 complained of intermittent nasal obstruction, two of whom showed a decrease in nasal airway volume by acoustic rhinometry. Conclusion: Most patients with nasal bone fractures accompanying grade I septal fractures have been treated with closed reduction in clinical settings. However, the results of this study suggest that septoplasty be performed after a correct diagnosis of septal fracture is made through comprehensive physical examination and computed tomography. Septoplasty is important to obtain more favorable outcomes and reduce complication.