• 제목/요약/키워드: interleaved two-loop control

검색결과 11건 처리시간 0.027초

2단 역률보상회로를 구성하는 Interleaved 승압형 컨버터의 해석 및 설계 (Analysis and Design of Interleaved Boost Power Factor Corrector on Two Stage AC/DC PFC Converter)

  • 허태원;손영대;김동완;김춘삼;박한석;우정인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권7호
    • /
    • pp.343-351
    • /
    • 2003
  • In this paper, interleaved boost converter is applied as a first-stage converter in switch mode power supply. The first-stage converter plays a role to improve power factor. Interleaved Boost Power Factor Corrector(IBPFC) can reduce input current ripple as a single voltage control loop only without inner current loop, because input current is divided each 50% by two switching devices. Each converter cell is also operated in discontinuous current mode and inductor current of each converter is discontinuous. Total input current which is composed by each converter cell is continuous current. Thus, IBPFC is able to improve input current ripple. IBPFC operating in discontinuous current mode can be classified as six modes from switching state and be carried out state space averaging small signal modeling. A control transfer function is obtained according to the modeling. Not only steady-state characteristics but also dynamic characteristics is considered. Single voltage control loop is also constructed by the control transfer function. From experimental result, improvement of power factor and input current ripple are verified.

Interleaved 승압형 역률 전치보상 컨버터의 설계 (Design of Interleaved Boost Power Factor Preregulator)

  • 허태원;노태균;정재륜;안인모;손영대;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1123-1125
    • /
    • 2002
  • In this paper, interleaved boost converter is applied as a pre-regulator in switch mode power supply. Interleaved Boost Power Factor Preregulator (IBPFP) can reduce input current ripple as a simple voltage control loop only without inner current loop, because input current is divided each 50% by two switching devices. IBPFP can be classified as three cases from duty ratio condition in continuous current mode and be carried out state space averaging small signal modeling. According to modeling, the PID controller is applied and voltage control loop is constructed for suitable design condition. From frequency domain analysis, it is verified that control system is satisfied with design condition of switch mode power supply.

  • PDF

A New Interleaved Double-Input Three-Level Boost Converter

  • Chen, Jianfei;Hou, Shiying;Sun, Tao;Deng, Fujin;Chen, Zhe
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.925-935
    • /
    • 2016
  • This paper proposes a new interleaved double-input three-level Boost (DITLB) converter, which is composed of two boost converters indirectly in series. Thus, a high voltage gain, together with a low component stress and a small input current ripple due to the interleaved control scheme, is achieved. The operating principle of the DITLB converter under the individual supplying power (ISP) and simultaneous supplying power (SSP) mode is analyzed. In addition, closed-loop control strategies composed of a voltage-current loop and a voltage-balance loop, have been researched to make the converter operate steadily and to alleviate the neutral-point imbalance issue. Experimental results verify correctness and feasibility of the proposed topology and control strategies.

Performance Improvement of Voltage-mode Controlled Interleaved Buck Converters

  • Veerachary Mummadi
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.104-108
    • /
    • 2005
  • This paper presents the performance improvement of voltage-mode controlled interleaved synchronous buck converters. This is a voltage-mode controlled scheme, where the controllers do not need an external saw-tooth generator for PWM generation and the loop design is easier. The controller implementation requires only a single error amplifier and gives almost current mode control performance. The control scheme uses voltage feedback with two loops similar to current mode control: one for the slow outer loop and the other for the faster inner PWM control loop. To improve the performance of the converter system a coupled inductor is used. This coupled inductor reduces the magnetic size and also improves the converter's transient performance without increasing the steady-state current ripple. The effectiveness of the proposed control scheme is demonstrated through PSIM simulations.

불연속 전류모드로 동작하는 Interleaved 승압형 역률보상 컨버터의 입력전류 리플개선 (Input Current Ripple Improvement on Interleaved Boost Power Factor Corrector Operating in Discontinuous Current Mode)

  • 허태원;박지호;노태균;김동완;박한석;우정인
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.116-123
    • /
    • 2003
  • 본 논문에서는 SMPS의 교류 입력측 역률을 개선시킬 수 있는 전치 레귤레이터로서 interleaved 승압형 컨버터를 관하여 연구하였다. Interleaved 승압형 역률보상 컨버터(IBPFC)는 입력전류를 두 개의 스위칭 소자에 의하여 50%씩 나누어져 흐르게 함으로써, 내부 전류제어 루프 얼이 전압제어 루프만으로 제어계를 구성하여 입력전류 리플을 줄일 수 있다. 즉, IBPFC를 구성하는 각각의 부스트 컨버터 cell을 불연속 전류모드로 동작시키더라도 전체적인 입력전류의 파형은 연속이 되어 입력전류 리플이 감소하게 된다. 불연속 전류모드로 동작하는 IBPFC를 해석하기 위하여 스위칭 상태에 따라서 6개의 모드로 구분하여 상태방정식을 구하였다. 또한, 각 상태방정식을 상태공간 평균화법을 이용하여 모델링하고, 미소변동분을 고려한 소신호 해석을 통하여 제어전달함수를 구할 수 있다. 또한, 제어전달함수를 이용하여 단일 전압제어 루프를 가지는 제어계를 설계하였으며, 이러한 해석 및 설계를 바탕으로 실험을 통하여 IBPFC의 역률개선 및 리플저감을 확인하였다.

New Single-stage Interleaved Totem-pole AC-DC Converter for Bidirectional On-board Charger

  • 함자 벨카멜;김상진;김병우;신양진;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.192-194
    • /
    • 2018
  • In this paper a new single-stage ac-dc converter with high frequency isolation and low components count is introduced. The proposed converter is constructed using two interleaved boost circuits in the grid side and non-regulating full bridge in the DC side. An optimized switching is implemented on the two interleaved boost circuits resulting in a ripple-free grid current without a ripple cancellation network; hence very small filter inductors are used. A simple and reliable closed-loop control system is easily implemented, since the phase-shift angle is the only independent variable. Moreover, current imbalance is avoided in the presented topology without current control loop in each phase. The proposed charger charges the battery with a sinusoidal-like current instead of a constant direct current. ZVS turn on of all switches is achieved throughout the operation in both directions of power flow without any additional components.

  • PDF

연료전지·이차전지 하이브리드 시스템을 위한 인터리빙 양방향 DC-DC 컨버터 설계 (The Design of Interleaved Bi-directional DC-DC Converter for Fuel Cell and Battery Hybrid System)

  • 김승민;최주엽;최익;송승호;이상철;이동하
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.45-53
    • /
    • 2013
  • Fuel cell power system is one of the most promising energy source for the alternative energy because it has unique advantages such as high energy density, no power drop during operation, and feasible to make compact size. However, due to very low response time, fuel cell is difficult to correspond to drastic load changes and start-up operation. For solving these problem, fuel cell power system must include energy storage device such as Li-Poly battery or super capacitor. Therefore, bi-directional DC-DC converter must be required for this storage device and fuel cell-PCS control. This paper presents a design and modeling of the bi-directional DC/DC converter. Firstly, we present modeling the boost and buck mode of the bi-directional converter through both PWM switch model and state space averaging technique. Secondly, in order to minimize output ripple and transient response overshoot, we have two identical DC-DC converters interleaved and adopt two-loop voltage-current controller. The proposed bi-directional DC-DC converter's modeling method and control design have been verified with computer simulation and experimentation.

편광상이 고리 형태의 다파장 스위칭 가능한 1차 광섬유 유연 필터의 스펙트럼 특성 (Spectral Characteristics of Multiwavelength-Switchable First-Order Fiber Flexible Filter based on Polarization-Diversity Loop)

  • 박경수;김영호;이용욱
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.6-13
    • /
    • 2014
  • In this paper, a multiwavelength-switchable first-order fiber flexible filter is newly proposed, which is based on a polarization-diversity loop. The proposed filter consists of a polarization beam splitter, three half-wave plates(HWPs), and two high birefringent fibers(HBFs). The proposed filter has a good flexibility in adjusting relative angular difference between the principal axes of two HBFs by inserting an HWP between two HBFs. The first-order flat-top or narrow band transmission spectra and the zeroth-order transmission spectra, which had a channel spacing of ~0.8nm, could be obtained by controlling the three HWPs, and, in particular, each of them could also be interleaved. In addition, zeroth-order transmission spectra with a channel spacing of ~0.8nm could be flexibly converted into those with a channel spacing of ~0.4nm through the control of three HWPs, and also be interleaved. The transmission characteristics of the proposed filter was theoretically analyzed and experimentally verified.

Two-Phase Hybrid Forward Convertor with Series-Parallel Auto-Regulated Transformer Windings and a Common Output Inductor

  • Wu, Xinke;Chen, Hui
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.757-765
    • /
    • 2013
  • For conventional interleaved two-phase forward converters with a common output inductor, the maximum duty cycle is 0.5, which limits the voltage range and increases the difficulty of the transformer's optimization. A new two-phase hybrid forward converter with series-parallel auto-regulated transformer windings is presented in this paper. With interleaved control signals for the two phases, the secondary windings of the transformers can work in series when the duty cycle is larger than 0.5, and they can work in parallel when duty cycle is lower than 0.5. Therefore, the maximum duty cycle is extended and the turns ratio of the transformer can be optimized. Duty cycle dependent auto-regulated windings result in the steady states of the converter being different in different duty cycle ranges (D>0.5 and D<0.5). Fortunately, the steady state gains of the proposed hybrid converter are identical at different duty cycle ranges, which means a stepless shift between two states. A prototype is built to verify the theoretical analysis. A conventional control loop is compatible for the whole input voltage range and load range thanks to the stepless shifting between the different duty cycle ranges.

역률과 전류 리플을 개선한 인터리브 AC/DC 컨버터에 관한 연구 (A Study of Interleaved AC/DC Converter to Improved Power Factor and Current Ripple)

  • 서상화;김용;권순도;배진용;엄태민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.152-155
    • /
    • 2009
  • In high power application, PFC(Power Factor Correction) pre-regulators are generally required. PFC pre-regulators could achieve unity power factor, reduce line input current harmonics and utilize full line power. Interleaving PFC converters could reduce input ripple current, output capacitor ripple current and inductor size. With this closed loop interleaving method, both two phase converters are working at the boundary between continuous and discontinuous mode and accurate 180 degree phase shift is achieved. Implementation of this strategy could be easily integrated to the control chip. Finally, experimental results of a two-phase interleaved boost PFC are presented to verify the discussed features.

  • PDF