• Title/Summary/Keyword: interlaced yarn

검색결과 5건 처리시간 0.016초

Pulsar Interlacing 장치를 이용한 Rain Melange 직물소재의 개발 (The Development of Rain Melange Fabrics with Using Pulsar Interlacing Unit)

  • 황종호;박성우
    • 한국의류산업학회지
    • /
    • 제4권4호
    • /
    • pp.399-404
    • /
    • 2002
  • The purpose of this study was to develop the rain melange fabrics with using the pulsar interlacing unit. The properties of the pulsar interlaced yarns (PI yarn) which were textured with the several texturing conditions were analyzed and compared with the regular interlaced yarn (IT yarn) and with normally composited yarn (CP yarn). The results were as follows : The PI yarn which has the best rain random melange effect could be obtained with following texturing condition; 3 kg/$cm^2$ of interlacing air pressure, 1.6 mm diameter of interlacing nozzle and 500 m/min of yarn speed. When IT yarn was compared with CP yarn, IT yarn had higher denier and tenacity than those of CP yarn and had lower elongation and shrinkage than those of CP yarn.

고치와 폴리에스텔 복합사 직물의 시직 (Studies on Fabrics woven with Silk/Polyester Compound Yarn)

  • 김영대;김남정
    • 한국잠사곤충학회지
    • /
    • 제36권2호
    • /
    • pp.147-151
    • /
    • 1994
  • 고급성과 위생성이 우수한 견과 실용적 특성이 우수한 합성섬유의 서로의 장점만을 가진 이상적인 직물을 개발코저 시험한 결과 고치와 polyester 복합사(S/P 복합사)와 복합 직물의 특성은 다음과 같다. 1. 자동조사기에 의한 복합사 제조시험 결과 빔을 5회 주었을때 보다 빔을 주지 않았을때 사조 집합도가 향상되었으며 빔을 주지 않고 공기교란 장치만으로 섬도 감지기의 작동도 정확히 이루어져 섬도편차가 양호한 S/P 복합사를 제조할 수 있었다. 2. S/P 복합사를 SEM으로 관찰한 결과 포합이 잘된 부분이 많았으나 견사는 견사끼리 polyester는 polyester 끼리 포합된 형태도 관찰되었다. 3. 직물을 SEM으로 관찰한 chiffon 직물은 강연을 한 결과 견사 부분이 polyester사 내부로 파묻힌 곳도 관찰되었다. 4. 분산염료와 산성염료 혼합용액에서 일욕 이단법으로 염색한 S/P 복합사 직물의 염색견뢰도는 habutae 직물은 일광견뢰도가 3급인 것을 제외하고는 모두 4급 이상으로 양호하였고 chiffon 직물은 모두 4급이상으로 양호하였다. 5. habutae 직물과 chiffon 직물의 특성을 보면 강력과 modulus는 생지에서 가장 크고 염색 가공지에서 크게 감소되었으며 신도는 정련지와 염색 가공지가 생지보다 증가되었다.

  • PDF

견과 나이론 복합사 스타킹의 품질 특성 (Physical characteristics of Stocking knitted with Silk/Nylon Compound Yarn)

  • 김영대;김남정;송기언
    • 한국잠사곤충학회지
    • /
    • 제36권1호
    • /
    • pp.58-61
    • /
    • 1994
  • 견과 합성 섬유의 단점을 서로 보완하여 새로운 성능을 가지는 신소재를 개발하기 위하여 견사와 나이론사와의 복합사를 제조(이하 S/N 복합사)하고 이들 복합사 스타킹에 대하여 품질을 평가한 결과는 다음과 같다. 1. SEM으로 S/N 복합사로 제편한 스타킹을 관찰한 결과 나이론사는 매끈하게 보이는 반면 견사는 약간 불규칙하게 나타나서 쉽게 판별할 수 있었으며 견사와 나이론사가 서로 잘 포합된 부분과 견사끼리 합쳐진 부분이 발견되었다. 2. S/N 복합사 스타킹의 흡수속도는 나이론 스타킹에 비하여 4~8배 높았고 무연보다 가연할 경우가 높았다. 흡수율에 있어서도 S/N 복합사 스타킹이 나이론 스타킹에 비하여 3배 이상 높았다. 3. 수축율을 보면 상온수에서는 나이론 스타킹과 S/N 스타킹간에 큰 차이는 없었으나 비등수에서는 나이론보다 S/N 스타킹편이 약간 많이 수축되었다. 한편 스타킹간의 수축율과 수축탄성율은 큰 차이는 없었다. 4. S/N 복합사 스타킹의 착용시험 결과 보온성, 촉감은 나이론 스타킹보다 우수하였으나 수축성은 나이론 스타킹에 미치지 못하였다. 그러나 종합적인 호감도는 나이론 스타킹에 비하여 우수한 것으로 나타났다.

  • PDF

연사방법에 따른 아세테이트/폴리에스터 복합사 편성물의 역학적 특성 및 3D CAD System에 의한 외관특성 (Mechanical Properties and 3D CAD Images of the Appearance of Knitted Fabric with Acetate/Polyester Composite Yarn by Different Yarn Twisting Methods)

  • 김소진;전동원;박영환
    • 한국염색가공학회지
    • /
    • 제18권1호
    • /
    • pp.33-43
    • /
    • 2006
  • The purpose of this study was to eximine the effect of different yam twisting methods on mechanical properties and 3D CAD images of plain knitted fabrics made of composite yarns. Six yams were used in this study: four different composite yams of the six consist of acetate and functional polyester (Poly-m) with the ratio of 70:30, and the rest two are the original acetate $100\%$ yam and the poly-m $100\%$ yarn. The four kinds of composite yarns were processed in combinations of twisting processes such as interlacing, false twisting, two for one twisting, combined twisting and single covering, and the two original yams were knitted without any twisting process. Sixteen mechanical properties of all the six knitted fabrics, knitted under the same knitting conditions, were measured by KES-FB system with the outer knit condition. The results were as follows; 1) When the sample applied with the false twisting process at the temperature as high as $220^{\circ}C$, ENT, B, HB, G and RC values of samples increased which leads to increasing dimensional stability. 2) To gain the high bending and shear properties in the single covering process, selecting the core yarn with such properties is the most important factor. 3) Interlacing process effected to increase RC value. 4) False twisting process after interlacing process gave bulkiness and un-interlaced part in yam was increased SMD value. The SMD value of the kilted fabric of the composite yarn, which was put through the combined twist process, was higher than those of which simple process such as the two for one twist or the single covering process applied. In order to achieve the silk-like surface feel of knitted fabric, the sin91e covering process is recommended. 5) Examining the simulation images of the knifed fabrics of composite yarn, which were generated by the 3D CAD system based on the mechanical properties of the fabric, led that appearance could be changed as different twisting methods were applied.

ECG 생체신호 측정을 위한 실용적 U-헬스케어 의복개발 (Development of the Practical Garment Apparatus to Measure Vital Sign of ECG for U-Health Care)

  • 박혜준;홍경희;김승환;신승철
    • 한국의류학회지
    • /
    • 제31권2호
    • /
    • pp.292-299
    • /
    • 2007
  • Development of portable device measuring the vital sign continuously with no limit of time and space is absolutely prerequisite for the U-health care that grafts the ubiquitous concept into medical system. Accordingly, it requires to develop a garment style apparatus for measuring vital-sign that is easy to wear on for a long time period. This study suggests a method to improve the insulation of electric cable and the skin adhesion of electrode by integrating the electric conductive material to garment, in order to develop a garment apparatus for measuring ECG for U-health care. Results of the research are as follows; In order to provide the adjacent conductive yarns with insulation, braid with narrow woven end was interlaced using polyester yarn. As a result, the direct contact between electric conductive yarns was restrained, which would be interposed into pin-tuck structured cable. Washable silicone gel applied around the electrode made of electric conductive fabric improved the adhesion, which prevents electrodes from dropping off from the skin surface during body movement. ECG signals on the human subject were tested using the garment apparatus developed by the above method. And the result was that the clear QRS wave formation in the typical form of ECG could be measured in both conditions of still and moving state as well. The result of this study is expected to contribute for the production of U-health care related medical apparatus by accelerating the practical uses of the garment measuring vital sign at a reasonable price.