• Title/Summary/Keyword: interface shear stress

검색결과 294건 처리시간 0.026초

균일 두께의 자성유체 피막이 있는 평면 벽을 향하는 2차원 정체 유동 (TWO-DIMENSIONAL STAGNATION FLOW TOWARD A PLANE WALL COATED WITH MAGNETIC FLUID OF UNIFORM THICKNESS)

  • 고형종;김경훈;김세웅
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.20-27
    • /
    • 2007
  • Two-dimensional stagnation flow toward a plane wall coated with magnetic fluid of uniform thickness is investigated. The flow field is represented as a similarity solution of the Navier-Stokes equation for this incompressible laminar flow. The resulting third order ordinary differential equation is solved numerically by using the shooting method and by determining two shooting parameters so as to satisfy the boundary and interface conditions. Features of the flow including streamline patterns are investigated for the varying values of density ratio, viscosity ratio, and Reynolds number. An adverse flow with double eddy pair in magnetic fluid region is found to emerge as the Reynolds number becomes higher than a threshold value. The results for the interface velocity, interface and wall shear stress, and boundary layer and displacement thickness are also presented.

Influence of polled direction on the stress distribution in piezoelectric materials

  • Ilhan, Nihat;Koc, Nagihan
    • Structural Engineering and Mechanics
    • /
    • 제54권5호
    • /
    • pp.955-971
    • /
    • 2015
  • In this paper, the influence of the polled direction of piezoelectric materials on the stress distribution is studied under time-harmonic dynamical load (time-harmonic Lamb's problem). The system considered in this study consists of piezoelectric covering layer and piezoelectric half-plane, and the harmonic dynamical load acts on the free face of the covering layer. The investigations are carried out by utilizing the exact equations of motion and relations of the linear theory of electro-elasticity. The plane-strain state is considered. It is assumed that the perfect contact conditions between the covering layer and half-plane are satisfied. The boundary value problems under consideration are solved by employing Fourier exponential transformation techniques with respect to coordinates directed along the interface line. Numerical results on the influence of the polled direction of the piezoelectric materials such as PZT-5A, PZT-5H, PZT-4 and PZT-7A on the normal stresses, shear stresses and electric potential acting on the interface plane are presented and discussed. As a result of the analyses, it is established that the polled directions of the piezoelectric materials play an important role on the values of the studied stresses and electric potential.

Effect of tapered-end shape of FRP sheets on stress concentration in strengthened beams under thermal load

  • El Mahi, Benaoumeur;Kouider Halim, Benrahou;Sofiane, Amziane;Khalil, Belakhdar;Abdelouahed, Tounsi;Adda Bedia, El Abbes
    • Steel and Composite Structures
    • /
    • 제17권5호
    • /
    • pp.601-621
    • /
    • 2014
  • Repairing and strengthening structural members by bonding composite materials have received a considerable attention in recent years. The major problem when using bonded FRP or steel plates to strengthen existing structures is the high interfacial stresses that may be built up near the plate ends which lead to premature failure of the structure. As a result, many researchers have developed several analytical methods to predict the interface performance of bonded repairs under various types of loading. In this paper, a numerical solution using finite - difference method (FDM) is used to calculate the interfacial stress distribution in beams strengthened with FRP plate having a tapered ends under thermal loading. Different thinning profiles are investigated since the later can significantly reduce the stress concentration. In the present theoretical analysis, the adherend shear deformations are taken into account by assuming a parabolic shear stress through the thickness of both beam and bonded plate. The shear correction factor for I-section beams is also included in the solution. Numerical results from the present analysis are presented to demonstrate the advantages of use the tapers in design of strengthened beams.

수직응력의 감소가 부마찰이 작용하는 말뚝의 거동에 미치는 영향 (The Influence of Reduction of Vertical Stress on the Behaviour of Piles Subjected to Negative Skin Friction)

  • 이철주
    • 대한토목학회논문집
    • /
    • 제29권1C호
    • /
    • pp.33-39
    • /
    • 2009
  • 부마찰이 작용하는 말뚝 주변지반의 수직 응력은 전단응력 전이 과정을 통해 감소하게 된다. 본 연구에서는 3차원 유한차분 해석을 실시하여 부마찰이 작용하는 단독말뚝 인근 지반의 수직응력 및 수평응력의 감소 및 그로 인한 말뚝의 거동변화에 대한 분석을 실시하였다. 또한 말뚝인근 지반의 수직응력 감소를 고려할 수 있는 간단한 식을 제안하였다. 말뚝에 부마찰이 작용하는 경우 Greenfield 조건에 비해 지반의 수직 및 수평응력이 상당히 크게 감소하는 것으로 나타났다. 수직응력이 감소되는 수평범위는 그리 넓지 않아서 최대 4-8 D 정도 인 것으로 분석되었다, 여기서 D는 말뚝의 직경이다. 본 연구를 통해 분석된 바에 의하면 부마찰력의 평가에 일반적으로 널리 이용되는 $\beta$-방법에 의해서는 부마찰력이 과다하게 평가될수 있는 것으로 나타났으며, 따라서 원래의 공식에 수직응력의 감소를 반영할 필요가 있는 것으로 판단된다.

틸팅차량용 차체의 Hybrid 복합재 접합체결부의 정적 및 피로 파괴 평가 (Static and Fatigue Fracture Assessment of Hybrid Composite Joint for the Tilting Car Body)

  • 정달우;김정석;서승일;조세현;최낙삼
    • 대한기계학회논문집A
    • /
    • 제31권2호
    • /
    • pp.166-173
    • /
    • 2007
  • Fatigue fracture behavior of a hybrid bolted joint was evaluated in comparison to the case of static fracture. Two kinds of specimens were fabricated for the mechanical tests; a hybrid bolted joint specimen for the shear test and a hybrid joint part specimen applied in the real tilting car body for the bending test. Characteristic fracture behaviors of those specimens under cyclic toads were obviously different from the case under static loads. For the hybrid bolted joint specimen, static shear loading caused the fracture of the bolt body itself in a pure shear mode, whereas cyclic shear loading brought about the fracture at the site of local tensile stress concentration. For the hybrid joint part specimen, static bend loading caused the shear deformation and fracture in the honeycomb core region, while cyclic bend loading did the delamination along the interface between composite skin and honeycomb core layers as well as the fracture of welded joint part. Experimental results obtained by static and fatigue tests were reflected in modifications of design parameters of the hybrid joint structure in the real tilting car body.

Experimental study on steel-concrete composite beams with Uplift-restricted and slip-permitted screw-type (URSP-S) connectors

  • Duan, Linli;Chen, Hongbing;Nie, Xin;Han, Sanwei
    • Steel and Composite Structures
    • /
    • 제35권2호
    • /
    • pp.261-278
    • /
    • 2020
  • In steel-concrete composite beams, to improve the cracking resistance of the concrete slab in the hogging moment region, a new type of connector in the interface, named uplift-restricted and slip-permitted screw-type (URSP-S) connector has been proposed. This paper focuses on the behavior of steel-concrete composite beams with URSP-S connectors. A total of three beam specimens including a simply supported beam with URSP-S connectors and two continuous composite beams with different connectors arrangements were designed and tested. More specifically, one continuous composite beam was equipped with URSP-S connectors in negative moment region and traditional shear studs in other regions. For comparison, the other one was designed with only traditional shear studs. The failure modes, crack evolution process, ultimate capacities, strain responses at different locations as well as the interface slip of the three tested specimens were measured and evaluated in-depth. Based on the experimental study, the research findings indicate that the larger slip deformation is allowed while using URSP-S connectors. Meanwhile, the tensile stress reduces and the cracking resistance of the concrete slab improves accordingly. In addition, the overall stiffness and strength of the composite beam become slightly lower than those of the composite beam using traditional shear studs. Moreover, the arrangement suggestion of URSP-S connectors in the composite beam is discussed in this paper for its practical design and application.

Vibration behavior of functionally graded sandwich beam with porous core and nanocomposite layers

  • Si, Hua;Shen, Daoming;Xia, Jinhong;Tahouneh, Vahid
    • Steel and Composite Structures
    • /
    • 제36권1호
    • /
    • pp.1-16
    • /
    • 2020
  • In steel-concrete composite beams, to improve the cracking resistance of the concrete slab in the hogging moment region, a new type of connector in the interface, named uplift-restricted and slip-permitted screw-type (URSP-S) connector has been proposed. This paper focuses on the behavior of steel-concrete composite beams with URSP-S connectors. A total of three beam specimens including a simply supported beam with URSP-S connectors and two continuous composite beams with different connectors arrangements were designed and tested. More specifically, one continuous composite beam was equipped with URSP-S connectors in negative moment region and traditional shear studs in other regions. For comparison, the other one was designed with only traditional shear studs. The failure modes, crack evolution process, ultimate capacities, strain responses at different locations as well as the interface slip of the three tested specimens were measured and evaluated in-depth. Based on the experimental study, the research findings indicate that the larger slip deformation is allowed while using URSP-S connectors. Meanwhile, the tensile stress reduces and the cracking resistance of the concrete slab improves accordingly. In addition, the overall stiffness and strength of the composite beam become slightly lower than those of the composite beam using traditional shear studs. Moreover, the arrangement suggestion of URSP-S connectors in the composite beam is discussed in this paper for its practical design and application.

Assessment of geometric nonlinear behavior in composite beams with partial shear interaction

  • Jie Wen;Abdul Hamid Sheikh;Md. Alhaz Uddin;A.B.M. Saiful Islam;Md. Arifuzzaman
    • Steel and Composite Structures
    • /
    • 제48권6호
    • /
    • pp.693-708
    • /
    • 2023
  • Composite beams, two materials joined together, have become more common in structural engineering over the past few decades because they have better mechanical and structural properties. The shear connectors between their layers exhibit some deformability with finite stiffness, resulting in interfacial shear slip, a phenomenon known as partial shear interaction. Such a partial shear interaction contributes significantly to the composite beams. To provide precise predictions of the geometric nonlinear behavior shown by two-layered composite beams with interfacial shear slips, a robust analytical model has been developed that incorporates the influence of significant displacements. The application of a higher-order beam theory to the two material layers results in a third-order adjustment of the longitudinal displacement within each layer along the depth of the beam. Deformable shear connectors are employed at the interface to represent the partial shear interaction by means of a sequence of shear connectors that are evenly distributed throughout the beam's length. The Von-Karman theory of large deflection incorporates geometric nonlinearity into the governing equations, which are then solved analytically using the Navier solution technique. Suggested model exhibits a notable level of agreement with published findings, and numerical outputs derived from finite element (FE) model. Large displacement substantially reduces deflection, interfacial shear slip, and stress values. Geometric nonlinearity has a significant impact on beams with larger span-to-depth ratio and a greater degree of shear connector deformability. Potentially, the analytical model can accurately predict the geometric nonlinear responses of composite beams. The model has a high degree of generality, which might aid in the numerical solution of composite beams with varying configurations and shear criteria.

수직력하에서 임프란트 나사형태에 따른 응력의 3차원 유한요소법적 분석 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS ACCORDING TO IMPLANT THREAD DESIGN UNDER THE AXIAL LOAD)

  • 김우택;차용두;오세종;박상수;김현우;박양호;박준우;이건주
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권2호
    • /
    • pp.111-117
    • /
    • 2001
  • There are three designs of thread form in screw type implants: V-thread, Reverse buttress thread and Square thread. The purpose of this study was to find out how thread form designs have an influence on the equivalent stress, equivalent strain, maximum shear stress and maximum shear strain and which design of thread form generates more maximum equivalent stress and strain. 3-D finite element analysis was used to evaluate the stress and strain patterns of three tread types. The results of this study were as follow. 1. Under the 200N of axial load, the value of maximum equivalent stress is smallest in square thread and there is no significant difference between that of V thread and reverse buttress thread. 2. Under the 200N of axial load, the value of maximum equivalent strain is largest in V thread and smallest in square thread. 3. Under the 200N of axial load, the value of maximum shear stress is smallest in square thread and there is no significant difference between that of V thread and reverse buttress thread. 4. Under the 200N of axial load, the value of maximum equivalent strain is largest in V thread and there is no significant difference between that of square thread and reverse buttress thread. 5. Above results show that the square thread has special advantages in stress and strain compared with other thread types, especially in shear stess which is most determinant to implant-bone interface. Considering the superior biomechanical properties of square form implant, we presume that square form implant has better clinical results than the other types of implants in the same clinical conditions.

  • PDF

현장시험을 통한 부력앵커의 거동분석 (An analysis of the Behaviour of Uplift-Resisting Ground Anchors from Pull-out Tests)

  • 이철주;전상현;유남재
    • 한국지반환경공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.33-40
    • /
    • 2007
  • 풍화암층에 시공된 부력앵커의 거동을 현장인발시험을 통하여 분석하였다. 부력앵커는 지하철역사의 지하층에 작용하는 부력을 저항하기 위하여 시공되었다. 본 연구에서는 부력앵커의 한계인발저항력과 앵커와 지반의 경계면에서의 전단응력 전이 메커니즘에 대한 분석을 실시하였다. 인발시험에서는 앵커의 정착장(2~7m)과 천공직경(108~165mm)을 변경시키면서 그 영향을 고찰하였다. 인발시험결과에 의하면 앵커의 한계인발력은 정착장의 길이 및 천공직경이 증가 할수록 증가하는 것으로 분석되었다. 인발시험을 통한 앵커의 한계인발력은 이러한 인자들에 따라 392~1,569kN의 범위를 보이는 것으로 분석되었다. 이로부터 경계면에서 227~505kPa 전단강도가 발생하는 것으로 산정되었다. 인발시험결과에 의하면 인발력의 크기가 증가할수록 전단강도의 발현정도가 증가하는 것으로 나타났다. 인발시험을 통해서 관찰된 파괴 형태는 앵커의 길이에 큰 영향을 받는 것으로 분석되었다. 앵커의 길이가 짧은 경우(2~3m) 콘 형태의 파괴가 관찰되었으며, 앵커의 길이가 증가한 경우(5~7m)는 앵커의 파괴가 앵커체와 주변지반과의 불연속면에서 발생하는 것으로 나타났다.

  • PDF