• Title/Summary/Keyword: interconnect

Search Result 569, Processing Time 0.022 seconds

Design Optimization of Differential FPCB Transmission Line for Flat Panel Display Applications (평판디스플레이 응용을 위한 차동 FPCB 전송선 설계 최적화)

  • Ryu, Jee-Youl;Noh, Seok-Ho;Lee, Hyung-Joo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.5
    • /
    • pp.879-886
    • /
    • 2008
  • This paper addresses the analysis and the design optimization of differential interconnects for Low-Voltage Differential Signaling (LVDS) applications. Thanks to the differential transmission and the low voltage swing, LVDS offers high data rates and improved noise immunity with significantly reduced power consumption in data communications, high-resolution display, and flat panel display. We present an improved model and new equations to reduce impedance mismatch and signal degradation in cascaded interconnects using optimization of interconnect design parameters such as trace width, trace height and trace space in differential flexible printed circuit board (FPCB) transmission lines. We have carried out frequency-domain full-wave electromagnetic simulations, time-domain transient simulations, and S-parameter simulations to evaluate the high-frequency characteristics of the differential FPCB interconnects. The 10% change in trace width produced change of approximately 6% and 5.6% in differential impedance for trace thickness of $17.5{\mu}m$ and $35{\mu}m$, respectively. The change in the trace space showed a little change. We believe that the proposed approach is very helpful to optimize high-speed differential FPCB interconnects for LVDS applications.

Ultrastructures of the Compound Eye in Dragonfly, Crocothemis servilia Drury (고추잠자리 複眼의 電子顯微鏡的 構造)

  • Paik, Kyong Ki;Choi, Choon Keun;Shin, Kil Sang
    • The Korean Journal of Zoology
    • /
    • v.15 no.3
    • /
    • pp.111-131
    • /
    • 1972
  • Fine structures of retina of an ommatidium in dragonfly, having eyes of closed rhabdom type, were studied under light and electron microscopes. The ommatidia consisted of eight retinular cells distributed in a circular pattern and the retinular layer in turn can be divided into three sublayers according to the number of cells in the retina. Each retinular cell has different starting points in the retina and the length of retinular cells is varied greatly; the length of one distal retinular cell shows one half of that of others. In the middle layer, three proximal retinular cells interconnect the adjacent two rhabdoms which are triangular in the appearence of the cross section which in turn consisted of tubular, parallel and lamellated microvilli. The rhabdom is formed by three rhabdomeres, each of which is separated by $120^{\circ}$ between them, but they can be distinguished into two parts according to electron density. Around the outer part of microvilli composing rhabdom, electron density was much less than the inner part of the structure. The microvilli of the inner part appear to be connected to the cytoplasm of retinular cells. Rough endoplsmic reticulum with enlarged cisternae runs through the vacuoles in the outer part of distal retinular cells. Abundant mitochondria concentrated in the vicinity of rhabdom are found at the central part of the retinular cells, while in the area of immediate vicinity of the rhabdom, prominent vacuoles are observed. Above the rhabdom of an ommtidium stands a crystalline cone which is consisted of four cone cells arranged radially along the axis. The crystalline cone is surrounded by cells containing pigment granules. The outermost photoreceptor element of an ommatidium is corneal lens.

  • PDF

A Review on the Bonding Characteristics of SiCN for Low-temperature Cu Hybrid Bonding (저온 Cu 하이브리드 본딩을 위한 SiCN의 본딩 특성 리뷰)

  • Yeonju Kim;Sang Woo Park;Min Seong Jung;Ji Hun Kim;Jong Kyung Park
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.8-16
    • /
    • 2023
  • The importance of next-generation packaging technologies is being emphasized as a solution as the miniaturization of devices reaches its limits. To address the bottleneck issue, there is an increasing need for 2.5D and 3D interconnect pitches. This aims to minimize signal delays while meeting requirements such as small size, low power consumption, and a high number of I/Os. Hybrid bonding technology is gaining attention as an alternative to conventional solder bumps due to their limitations such as miniaturization constraints and reliability issues in high-temperature processes. Recently, there has been active research conducted on SiCN to address and enhance the limitations of the Cu/SiO2 structure. This paper introduces the advantages of Cu/SiCN over the Cu/SiO2 structure, taking into account various deposition conditions including precursor, deposition temperature, and substrate temperature. Additionally, it provides insights into the core mechanisms of SiCN, such as the role of Dangling bonds and OH groups, and the effects of plasma surface treatment, which explain the differences from SiO2. Through this discussion, we aim to ultimately present the achievable advantages of applying the Cu/SiCN hybrid bonding structure.

Reliability of Cu Interconnect under Compressive Fatigue Deformation Varying Interfacial Adhesion Treatment (유연소자용 기판과의 접착 특성에 따른 구리 배선의 압축 피로 거동 및 신뢰성)

  • Min Ju Kim;Jeong A Heo;Jun Hyeok Hyun;So-Yeon Lee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.105-111
    • /
    • 2023
  • Electronic devices have been evolved to be mechanically flexible that can be endured repetitive deformation. This evolution emphasizes the importance of long-term reliability in metal wiring connecting electronic components, especially under bending fatigue in compressed environments. This study investigated methods to enhance adhesion between copper (Cu) and polyimide (PI) substrates, aiming to improve the reliability of copper wiring under such conditions. We applied oxygen plasma treatment and introduced a chromium (Cr) adhesion layer to the polyimide substrate. Our findings revealed that these adhesion enhancement methods significantly affect compression fatigue behavior. Notably, the chromium adhesion layer, while showing weaker fatigue characteristics at 1.5% strain, demonstrated superior performance at 2.0% strain with no delamination, outperforming other methods. These results offer valuable insights for improving the reliability of flexible electronic devices, including reducing crack occurrence and enhancing fatigue resistance in their typical usage environments.

Study on the Proposal for Deposit Linkage Plan Based on the Survey of Online Material Identification System (온라인 자료 식별체계 실태조사를 기반으로 한 납본연계방안 제안 연구)

  • Younghee Noh;Aekyoung Son;Kyung Sun Lee;Inho Chang;Youngmi Jung;Hyunju Cha
    • Journal of the Korean Society for information Management
    • /
    • v.41 no.1
    • /
    • pp.133-162
    • /
    • 2024
  • The rapid digitalization has highlighted the importance of identifying and managing online resources. Especially, the need for a systematic identification system for the efficient distribution and preservation of digital content is growing. This study aims to respond to these contemporary demands by investigating the current state of identification systems for online resources and exploring more systematic management and utilization methods through linking these systems with legal deposit. To achieve this, the study surveyed the identification systems and their issuance status for online resources and analyzed prior research related to these online resources. Based on the analysis, the proposed strategies for linking with legal deposit can be summarized into three categories: First, to prioritize and enhance the utilization of legal deposit, strategies are required to strengthen the mutual complementarity of deposit and use, to assign priorities to certain deposits, and to increase the usability of deposited materials. Second, as strategies based on international standard numbers for linking with legal deposit, it is necessary to integrate ISBN and UCI in the deposit process, to link international standard resource numbers with deposit, to interconnect metadata between international standard numbers and UCI, to integrate UCI and ICN, and to introduce automation technology for upgrading the deposit system. Third, to effectively implement the aforementioned strategies, policy support is essential. This includes enhancing the role of the Korean Bibliographic Standards Center, strengthening cooperation with publishers, compensating for deposited materials, and increasing awareness and institutional compensation for the legal deposit system.

Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System (KSTAR 전류전송계통 진공배기계 구축 및 시운전)

  • Woo, I.S.;Song, N.H.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, Jae-Sik;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.483-488
    • /
    • 2007
  • Current feeder system (CFS) for Korea superconducting tokamak advanced research(KSTAR) project plays a role to interconnect magnet power supply (MPS) and superconducting (SC) magnets through the normal bus-bar at the room temperature(300 K) environment and the SC bus-line at the low temperature (4.5 K) environment. It is divided by two systems, i.e., toroidal field system which operates at 35 kA DC currents and poloidal field system wherein 20$\sim$26 kA pulsed currents are applied during 350 s transient time. Aside from the vacuum system of main cryostat, an independent vacuum system was constructed for the CFS in which a roughing system is consisted by a rotary and a mechanical booster pump and a high vacuum system is developed by four cryo-pumps with one dry pump as a backing pump. A self interlock and its control system, and a supervisory interlock and its control system are also established for the operational reliability as well. The entire CFS was completely tested including the reliability of local/supervisory control/interlock, helium gas leakage, vacuum pressure, and so on.

A Study on the Accessability of the Bikeway Networks in the South of the Han River Using Space Syntax (Space Syntax를 이용한 한강이남 자전거도로망의 접근성 분석)

  • Oh, Chung-Won;Lim, Dong-Wook;Kim, Hyun-Jin;Park, Jun-Tae
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.97-110
    • /
    • 2012
  • In case of the axial line bikeway, the residents in the riverside use it frequently but those in the city center hardly do as the axis is formed along the riverside of the Han river. This situation happens due to the inefficient connectivity between the bikeway that leads to the riverside and that in the city center, which means the administrative policies have been focused on the facilities rather than on raising connectivity of the bikeway networks in the south of the Han River. Also, this is the point of time when a reasonable improvement plan is needed to raise the accessibilities of the bikeways in Seoul, not just a utilization of those in the south of the Han River. This study intends to analyse the connectivity between Gangseo (west of the Han River) and Gangdong (East of the Han River) districts by comparing the current spatial structure in the southern areas of the Han River and that after the installation of the axial line, and that after installation of the ordinary bikeway respectively with use of the Space Syntax Model, and to predict resultant changes there of. The Space Syntax Model was used as the major method of analysis in this study to find out characteristics of the bikeways in the south of the Han River. Consequently, as the analysis shows that when the bikeways in the Gangseo and Gangdong-gu districts are connected, the accessibility of the bikeways in the south of the Han River will improve while the spatial structure intelligibility will be lowered, it can be said the prediction rate in the all areas is low compared with the current status. It is analyzed that the intelligibility of the current bikeways in the south of the Han River appeared highest when compared with those of plans for installation of the axial line and ordinary bikeway because they don't interconnect with other areas.

DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination (HVDC 슬립 온형 기중 종단접속함에 대한 열 영향 반영 DC 전계 특성 평가)

  • Kwon, Ik-Soo;Hwang, Jae-Sang;Koo, Jae-Hong;Sakamoto, Kuniaki;Lee, Bang-Wook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • A outdoor termination installed at the outdoor substation is required to connect undergroud cables and overhead transmission lines. The joint box for AC transmission system is already developed and widely used to interconnect overhead and undergroud systems. But the development of the joint box for DC transmission system was only introduced from China and Japan, but theire developemnt staus and core technologies were not fully reported. In order to implement HVDC systems connecting ovehead transmission lines and undergroud cables, a outdoor termination should be developed, but the detailed specifications and information of this device were not reported. It is estimated that the development of the joint box for DC environment has some technical obstacles including insulating materials, electric field mitigation, thermal temperature rise, and space charge accumuations. Among this, the most important one is the DC elctrical insualtion design. Therefore, in order to investigate the DC elctrical insualton design of outdoor termination, the design of AC slip-on type outdoor termination is reffered, and DC electric field analysis performed to verify the possiblity of application of AC joint box into DC joint box. Especially for DC electric field analysis, temperature rise of insualting materials of a joint box was considered, because the conductivity of materials could be changed due to temperature rise. Furthermore, DC electric field analysis considering transinet state, and polarity reversal state were also investigated to verify which state is the most severe condition for the DC joint box. From the simualtion resulsts, it was shown that the value and the position of maximum electric field was obtained comparing AC state, DC state without temperaure rise, and DC state with temperaure rise. And it was confimred that severe DC electric field was observed considing temperaure rise. Finally, in order to reduce DC eletric field intensifation, different configuration of the joint box was applied and it was not possible to obtain satisfactory results. It means that the slight change of configuration of AC joint box was not the suitable soluton for DC joint box. It is essential to establish novel DC insulaton design skills and method for DC joint box to commercialze this product in the near future.

A Study on the Factors affecting the Utilization of Waterscape Facilitiesin Apartment Complexes based upon Resident Perception - Focused on the Factors of Planning·Design, Maintenance and Usage - (주민인식에 기반한 아파트단지 내 수경시설 이용 영향 요인 분석 - 계획·설계, 유지·관리, 이용 행태를 중심으로 -)

  • Park, Do-Hwan;Cho, Se-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.62-75
    • /
    • 2017
  • This study analyzes the multiple effects of the following three aspects of waterscape facilities within apartment complexes: planning/designing, maintenance/management, and use of the facilities and suggests primary documents that will be fundamental for the methods to accelerate the implementation of waterscape facilities. A survey and analysis was conducted among a few of the most representative private apartment complexes in Seoul in accordance with the management and operation of waterscape facilities. The analysis used frequency analysis, descriptive statistics, reliability test, t-test, and PLS regression analysis. The research findings are as follows: first, the degree of use of waterscape facilities was found to be low regardless of the levels of operation, but residents' preference for the facilities was shown to be high, thus indicating there are still high expectations on the part of residents. Second, regardless of whether the facilities are being operated efficiently, the two items of location and display method under the section of planning and designing and the two items of aptitude and convenience under the section of use were found to positively affect the operation and use of waterscape facilities. Particularly, the item of freshness, cleanliness was shown to be directly and indirectly correlated with obsolescence, administration costs, and noise, which negatively affect the operation. Third, it was found that the administration costs itself that had been shown as the most negative factor of operating landscaping facilities in previous research did not cause problems in the residential area where the facilities are not operated efficiently. The finding suggests that the administration costs do not matter but that in the case of experience- and entertainment-typed facilities that residents want, they are linked to problems that do not introduce the desired facilities. Fourth, it was found that various aspects of planning, designing, maintaining, and using facilities interconnect and affect one another in the process of operating and using waterscape facilities resulting in the need to have a comprehensive approach to these three factors of planning, design, maintenance, management, and utilization. This study proposes that the needs and values of residents should be reflected to activate the introduction of landscaping facilities in the apartment complexes.