• Title/Summary/Keyword: interactive factor

Search Result 256, Processing Time 0.027 seconds

Axial load-strain relationships of partially encased composite columns with H-shaped steel sections

  • Bangprasit, Papan;Anuntasena, Worakarn;Lenwari, Akhrawat
    • Steel and Composite Structures
    • /
    • v.45 no.1
    • /
    • pp.51-66
    • /
    • 2022
  • This paper presents the axial compression behavior of partially encased composite (PEC) columns using H-shaped structural steel. In the experimental program, a total of eight PEC columns with H-shaped steel sections of different flange and web slenderness ratios were tested to investigate the interactive mechanism between steel and concrete. The test results showed that the PEC columns could sustain the load well beyond the peak load provided that the flange slenderness ratio was not greater than five. In addition, the previous analytical model was extended to predict the axial load-strain relationships of the PEC columns with H-shaped steel sections. A good agreement between the predicted load-strain relationships and test data was observed. Using the analytical model, the effects of compressive strength of concrete (21 to 69 MPa), yield strength of steel (245 to 525 MPa), slenderness ratio of flange (4 to 10), and slenderness ratio of web (10 to 25) on the interactive mechanism (Kh = confinement factor for highly confined concrete and Kw = reduction factor for steel web) and ductility index (DI = ratio between strain at peak load and strain at proportional load) were assessed. The numerical results showed that the slenderness of steel flange and yield strength of steel significantly influenced the compression behavior of the PEC columns.

Utility Interactive Photovoltaic Generation System Using Discontinuous Mode Buck-Boost Chopper (불연속모드 승강압초퍼를 이용한 계통연계형 태양광발전 시스템)

  • 김영철;이현우;서기영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.325-331
    • /
    • 1999
  • In a utility interactive photovoltaic generation system. a PWM inverter is used for the connection between the p photovoltaic arrays and the utility. The dc current becomes pulsated when the conventional inverter system operates i in the continuous current mode and de current pulsation causes the distortion of the accurrent waveform. This paper p presents the reduced pulsation of de input current by operating the inverter with buck-boost chopper in the d discontinuous conduction mode. The dc current which contains harmonic component is analyzed by means of s separating into two terms of a ripple component and a direct component. The constant dc current without p pulsation is supplied from photovoltaic array to the inverter. The proposed inverter system provides a sinusoidal ac c current for domestic loads and the utility line with unity power factor.

  • PDF

Development of a Health Literacy Assessment Scale for Asian Immigrant Women in South Korea (결혼이주여성의 건강문해력 측정도구 개발)

  • An, Jisook;Yang, Sook Ja
    • Research in Community and Public Health Nursing
    • /
    • v.26 no.4
    • /
    • pp.330-341
    • /
    • 2015
  • Purpose: This study developed a self-report measure for easy assessing of the health literacy of Asian immigrant women in South Korea. Methods: After a literature review, focus group interviews, and content validity evaluation, 14 preliminary items were generated. These were translated into Chinese, Vietnamese, and English. Data were collected from 229 Asian immigrant women. Validity and reliability tests were conducted. Results: Factor analysis yielded final 10 items in three factors: primary functional and interactive health literacy, secondary functional and interactive health literacy, and critical health literacy, which explained 61.90% of the total variance of health literacy. In known-group comparisons, health literacy was significantly lower in recent immigrants, those with a low education level, and those with low Korean language proficiency. For convergent validity, health literacy was positively associated with health specific self-efficacy and maternal health knowledge. For criterion-related validity, health literacy was positively associated with the REALM-SF. The overall reliability coefficient (Cronbach's ${\alpha}$) of the instrument was .773. Conclusion: The Health Literacy Assessment Scale for Asian Immigrant Women (HLAS) represents a multidimensional construct which encompasses functional, interactive, and critical health literacy. This self-report HLAS can be a useful and convenient method for appraising the health literacy of Asian immigrant women.

A Study on the Meaning of Prototypes and Prototyping Strategy in User Interface Design (사용자 인터페이스 디자인에서 프로토타입의 의미와 프로토타이핑 전략에 대한 연구)

  • 박정순
    • Archives of design research
    • /
    • v.13 no.3
    • /
    • pp.145-152
    • /
    • 2000
  • Since interactive systems that the user interaction is important factor can be very complex, its design process may have various testing and feedback based on continuous prototyping. The prototypes in this process function as medium to explore design problem and communicate opinions with another expert of project team. So prototyping strategy may be needed to enhance the design quality by focusing on the goals of project. This study clarifies critical issues around the prototypes and characteristics of interactive system to understand broad meaning of prototypes. And prototype model proposes as a framework for establishment of prototyping stategy.

  • PDF

Utility-Interactive Modulated Sinewave Inverter with a High Frequency Flyback Transformer Link for Small-Scale Solar Photovoltaic Generator

  • Konishi Y.;Chandhaket S.;Ogura K.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.683-686
    • /
    • 2001
  • This paper presents a novel prototype of the utility­interactive voltage source type sinewave pulse modulated power inverter using a high-frequency flyback transformer link. The proposed power conditioner circuit for the solar photovoltaic generation and small scale fuel cell has an isolation function due to the safety of the power processing system, which is more cost effective and acceptable for the small-scale distributed renewal energy conditioning and processing systems. The discontinuous current mode(DCM) of this power processing conversion circuit is applied to implement a simple circuit topology and pulse modulated control scheme. Its operation principle is described on the basis of simulation evaluations and theoretical considerations. The simulation results obtained herein prove that the proposed inverter outputs with sinusoidal waveforms and unity power factor currents are synchronized to the main voltage in utility power source grid. In this paper, the soft switching topology of high­frequency linked sinewave pulse modulation inverter is proposed and discussed.

  • PDF

Interactivity and User-Centered Design Strategies of Instructional Systems used in Web Environments (학습자 중심 웹 기반 교수-학습체제의 설계전략과 상호작용성)

  • Kim, Mi-Ryang
    • Journal of The Korean Association of Information Education
    • /
    • v.3 no.1
    • /
    • pp.13-21
    • /
    • 1999
  • 'Interactivity' is considered as a key factor of user-centered interactive instructional systems design in Web environments. To provide an optimal level of interactivity for learners is an ideal goal in instructional systems design(ISD) process. Based on the primary concern of interactive systems design which pursues how the power of interactivity can be utilized and put to work, several interactive design strategies in Web-based systems are recommended through this research.

  • PDF

Design of game interface based on 3-Axis accelerometer for physical Interactive game (체감형 게임을 위한 3축 가속도 센서 기반 게임 인터페이스 개발)

  • Kim, Sung-Ho;Chae, Bu-Kyung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.4
    • /
    • pp.538-544
    • /
    • 2009
  • As the world game marcket has been recording weak growth, the development of new gane concept is required to attract the gamer's attention from those who were fed up with the previous game paradigm. Recently, the game which can recognize the player's motions and provide new interaction between the game and user is more popular than ever before. In the games with somesthesia based on Virtual Reality, the sense of the reality is considered the most important factor for drawing immersion from the gamers. In this work, a new type of 3-axis accelerometer based interactive game interface which can effectively recognize the gamer' motion is suggested. Furthermore, various experiments are carried out to verify the effectiveness of the proposed scheme.

Interactive Animation by Action Recognition (동작 인식을 통한 인터랙티브 애니메이션)

  • Hwang, Ji-Yeon;Lim, Yang-Mi;Park, Jin-Wan;Jahng, Surng-Gahb
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.269-277
    • /
    • 2006
  • In this paper, we propose an interactive system that generates emotional expressions from arm gestures. By extracting relevant features from key frames, we can infer emotions from arm gestures. The necessary factor for real-time animation is tremendous frame rates. Thus, we propose processing facial emotion expression with 3D application for minimizing animation time. And we propose a method for matching frames and actions. By matching image sequences of exagerrated arm gestures from participants, they feel that they are communicating directly with the portraits.

  • PDF

A Novel Three-Phase Line-Interactive UPS System having AC Line Reactor and Parallel-Series Active Filters (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 라인 인터렉티브 무정전전원장치 시스템)

  • Ji Jun-Keun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.193-197
    • /
    • 2004
  • The four-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. In this paper a novel line interactive Uninterruptible Power Supply(UPS) using the two four-leg VSCs is proposed. One VSC is in parallel with the ac link reactor of the power source side, and the other is in series with the load. The parallel four-leg voltage source inverter controls the three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series four-leg voltage source inverter compensates the line voltage and allows it to be balanced and harmonic-free. Both of the parallel and series four-leg voltage source inverters always act as independently controllable voltage sources, so that the three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulations results.

  • PDF

Identification of Contract Foodservice Management Companies' Push, Pull, and Interactive Push-Pull Factors for Internationalization by In-Depth Interview (심층면접을 활용한 위탁급식업체 국제화 추진, 유인 및 상호작용 요인 항목 선정)

  • Lee, Hyun-A;Han, Kyung-Soo
    • Journal of the Korean Society of Food Culture
    • /
    • v.24 no.4
    • /
    • pp.401-412
    • /
    • 2009
  • The aims of study were to provide basic data for the internationalization of Contract Foodservice Management Companies (CFMC) and to gain a better understanding of internal push-and-pull factors through in-depth interviews. The interviewees were managers of four large CFMCs and one small-to-medium CFMC. The non-structured interview format employed an interview guide of open-ended questions. All interviews were digitally recorded and notes were taken simultaneously by an interview assistant. The narrative data analysis involved transcription, coding, classification by categories, and content analysis. Eighty-eight codes were generated from the interview analyses, and the subordinate variables uncovered included seven push factors, eight pull factors, one interactive factor, and 10 internal dynamics. These factors will be useful in further studies of the internal operations of specific CFMCs, and more generally, the practical condition of the industry.