• Title/Summary/Keyword: intelligent diagnosis

Search Result 393, Processing Time 0.023 seconds

Cost-Sensitive Case Based Reasoning using Genetic Algorithm: Application to Diagnose for Diabetes

  • Park Yoon-Joo;Kim Byung-Chun
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2006.06a
    • /
    • pp.327-335
    • /
    • 2006
  • Case Based Reasoning (CBR) has come to be considered as an appropriate technique for diagnosis, prognosis and prescription in medicine. However, canventional CBR has a limitation in that it cannot incorporate asymmetric misclassification cast. It assumes that the cast of type1 error and type2 error are the same, so it cannot be modified according ta the error cast of each type. This problem provides major disincentive to apply conventional CBR ta many real world cases that have different casts associated with different types of error. Medical diagnosis is an important example. In this paper we suggest the new knowledge extraction technique called Cast-Sensitive Case Based Reasoning (CSCBR) that can incorporate unequal misclassification cast. The main idea involves a dynamic adaptation of the optimal classification boundary paint and the number of neighbors that minimize the tatol misclassification cast according ta the error casts. Our technique uses a genetic algorithm (GA) for finding these two feature vectors of CSCBR. We apply this new method ta diabetes datasets and compare the results with those of the cast-sensitive methods, C5.0 and CART. The results of this paper shaw that the proposed technique outperforms other methods and overcomes the limitation of conventional CBR.

  • PDF

A Study on the On-Line Fault Diagnosis and Restorative Control Expert System for a Substation Simulator (변전소 시뮬레이터의 온라인 고장진단 및 복구제어 전문가 시스템에 대한 연구)

  • Lee, H.J.;Chung, S.J.;Lim, C.H.;Cho, K.R.;Shin, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.110-112
    • /
    • 1999
  • Recently the substation automation is actively researched at each country. Since the substation automation is an integrated system that consist of electrical, electronic and computer technologies, performance evaluation is very important to inspect the developed system's applicable possibility for real power system. Most studies are verified using computer simulation, because it is hard to apply them to real power systems. Therefore development of a substation simulator is necessary for the performance evaluation of many application systems such as operator aid system. This paper introduces a substation simulator. An intelligent fault diagnosis and restorative control expert system is also introduced UDP/IP is applied as a protocol for data transport between expert system and SC(station computer). As to the Graphic User Interface, C++ Language and Visual Basic is used in the Windows NT operating system together with four Pentium II systems.

  • PDF

An Availability of Low Cost Sensors for Machine Fault Diagnosis

  • SON, JONG-DUK
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.394-399
    • /
    • 2012
  • In recent years, MEMS sensors show huge attraction in machine condition monitoring, which have advantages in power, size, cost, mobility and flexibility. They can integrate with smart sensors and MEMS sensors are batch product. So the prices are cheap. And the suitability of it for condition monitoring is researched by experimental study. This paper presents a comparative study and performance test of classification of MEMS sensors in target machine fault classification by 3 intelligent classifiers. We attempt to signal validation of MEMS sensor accuracy and reliability and performance comparisons of classifiers are conducted. MEMS accelerometer and MEMS current sensors are employed for experiment test. In addition, a simple feature extraction and cross validation methods were applied to make sure MEMS sensors availabilities. The result of application is good for using fault classification.

  • PDF

The Study of Gateway Control Module Using SAE J1939 Protocol (SAE J1939 프로토콜기반 Gateway 제어모듈 개발에 관한 연구)

  • Ko, Youngjin;Kim, Doyeong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.1
    • /
    • pp.128-136
    • /
    • 2013
  • This study presents the development of Gateway Control Module using SAE J1939 protocol for the commercial vehicles. Presently, the load rate of CAN bus is increased by the single network composition and addition of new ECUs for development of intelligent vehicles. Because the embedded system of the integrated network control function has the errors of the CAN bus caused by the increase of ECU, it is needed for development of commercial vehicles. Also, this study presents the development of smart functions that can diagnosis CAN bus errors, fault diagnosis of ECU and basic function that arbitrates CAN bus between ECUs of commercial vehicle. GCM was designed for 4channel separation about Gateway function as solution of load rate decrease and smart functions. HILS(Hardware in the loop simulation)system that can achieve simulation about CAN Messages of all systems on vehicle was applied to evaluate performance and verification of all functions and performance. The load rate on CAN bus was decreased at using functions what was delivery, block and process of GCM. Through this, it was enabled to organize systematic architecture for gateway.

Easy Detection of Amyloid β-Protein Using Photo-Sensitive Field Effect

  • Kim, Kwan-Soo;Ju, Jong-Il;Song, Ki-Bong
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.339-344
    • /
    • 2012
  • This article describes a novel method for the detection of amyloid-${\beta}$($A{\beta}$) peptide that utilizes a photo-sensitive field-effect transistor (p-FET). According to a recent study, $A{\beta}$ protein has been known to play a central role in the pathogenesis of Alzheimer's disease (AD). Accordingly, we investigated the variation of photo current generated from p-FET with and without intracellular magnetic beads conjugated with $A{\beta}$ peptides, which are placed on the p-FET sensing areas. The decrease of photo current was observed due to the presence of the magnetic beads on the channel region. Moreover, a similar characteristic was shown when the Raw 264 cells take in magnetic beads treated with $A{\beta}$ peptide. This means that it is possible to simply detect a certain protein using magnetic beads and a p-FET device. Therefore, in this paper, we suggest that our method could detect tiny amounts of $A{\beta}$ for early diagnosis of AD using the p-FET devices.

Operational Availability Improvement through Online Monitoring and Advice For Emergency Diesel Generator

  • Lee, Jong-Beom;Kim, han-Gon;Kim, Byong-Sub;M. Golay;C.W. Kang;Y. Sui
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.264-270
    • /
    • 1998
  • This research broadens the prime concern of nuclear power plant operations from safe performance to both economic and safe performance. First emergency diesel generator is identified as one of main contributors for the lost plant availability through the review of plants forced outage records. The framework of an integrated architecture for performing modern on-line condition for operational availability improvement is configured in this work. For the development of the comprehensive sensor networks for complex target systems, an integrated methodology incorporating a structural hierarchy, a functional hierarchy, and a fault-system matrix is formulated. The second part of our research is development of intelligent diagnosis and maintenance advisory system, which employs Bayesian Belief networks (BBNs) as a high level reasoning tool incorporating inherent uncertainty use in probabilistic inference. Our prototype diagnosis algorithms are represented explicitly through topological symbols and links between them in a causal direction. As new evidence from sensor network development is entered into the model especially, our advisory of system provides operational advice concerning both availability and safety, so that the operator is able to determine the likely modes, diagnose the system state, locate root causes, and take the most advantageous action. Thereby, this advice improves operational availability

  • PDF

Fault-Tolerant Control System for Unmanned Aerial Vehicle Using Smart Actuators and Control Allocation (지능형 액추에이터와 제어면 재분배를 이용한 무인항공기 고장대처 제어시스템)

  • Yang, In-Seok;Kim, Ji-Yeon;Lee, Dong-Ik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.10
    • /
    • pp.967-982
    • /
    • 2011
  • This paper presents a FTNCS (Fault-Tolerant Networked Control System) that can tolerate control surface failure and packet delay/loss in an UAV (Unmanned Aerial Vehicle). The proposed method utilizes the benefits of self-diagnosis by smart actuators along with the control allocation technique. A smart actuator is an intelligent actuation system combined with microprocessors to perform self-diagnosis and bi-directional communications. In the event of failure, the smart actuator provides the system supervisor with a set of actuator condition data. The system supervisor then compensate for the effect of faulty actuators by re-allocating redundant control surfaces based on the provided actuator condition data. In addition to the compensation of faulty actuators, the proposed FTNCS also includes an efficient algorithm to deal with network induced delay/packet loss. The proposed algorithm is based on a Lagrange polynomial interpolation method without any mathematical model of the system. Computer simulations with an UAV show that the proposed FTNCS can achieve a fast and accurate tracking performance even in the presence of actuator faults and network induced delays.

An application of datamining approach to CQI using the discharge summary (퇴원요약 데이터베이스를 이용한 데이터마이닝 기법의 CQI 활동에의 황용 방안)

  • 선미옥;채영문;이해종;이선희;강성홍;호승희
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2000.11a
    • /
    • pp.289-299
    • /
    • 2000
  • This study provides an application of datamining approach to CQI(Continuous Quality Improvement) using the discharge summary. First, we found a process variation in hospital infection rate by SPC (Statistical Process Control) technique. Second, importance of factors influencing hospital infection was inferred through the decision tree analysis which is a classification method in data-mining approach. The most important factor was surgery followed by comorbidity and length of operation. Comorbidity was further divided into age and principal diagnosis and the length of operation was further divided into age and chief complaint. 24 rules of hospital infection were generated by the decision tree analysis. Of these, 9 rules with predictive prover greater than 50% were suggested as guidelines for hospital infection control. The optimum range of target group in hospital infection control were Identified through the information gain summary. Association rule, which is another kind of datamining method, was performed to analyze the relationship between principal diagnosis and comorbidity. The confidence score, which measures the decree of association, between urinary tract infection and causal bacillus was the highest, followed by the score between postoperative wound disruption find postoperative wound infection. This study demonstrated how datamining approach could be used to provide information to support prospective surveillance of hospital infection. The datamining technique can also be applied to various areas fur CQI using other hospital databases.

  • PDF

A study on the application of the IEC61850 based eCMD convergence structure in Digital Substation (IEC61850 기반 디지털 변전시스템에서의 eCMD 융합화구조 적용에 관한 연구)

  • Lee, D.C.;Kim, H.S.;Bae, U.L.;Min, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.19-22
    • /
    • 2006
  • The CMD(Condition Monitoring & Diagnosis) System is used to monitor and analyze the PD(Partial Discharge), Arc, Temperature, Pressure, Gas in Oil and so on for reliability and availability of the substation. Although this system comes into the spotlight as the forecast and management of the failure and fault, there are some problems. For example, the unified standard was not defined, and the effective management of the layed communication network does not performed, limitation of physical space, etc. To resolve above problems, this paper suggests the IEC61850 compatible eCMD system architecture for monitoring and analyzing the CMD factor in substations. The suggested eCMD system consists of CMD-LU(Condition Monitoring & Diagnosis-Local Unit), IED(Intelligent Electronic Device), and engineering centers. The IEC61850 is the international standard that defines communication networks and system in substation.

  • PDF

Study on the Damage Diagnosis of an Cantilever Beams using PZT Actuator and PVDF Sensor (PZT 액추에이터와 PVDF센서를 이용한 외팔보의 손상 진단에 관한 연구)

  • 권대규;임숙정;유기호;이성철
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.73-82
    • /
    • 2004
  • This paper presents the study on damage diagnosis of an intelligent cantilevered beams using PZT actuator and PVDF sensor This study provides the theoretical and experimental verification to examine structural damage. Time domain analysis for the non-destructive detection of damage is presented by parameterized partial differential equations and Galerkin approximation techniques. The time histories of the vibration response of structure were used to identify the presence of damage. Furthermore, this systematic approach permits one to use the piezomaterials to both excite and sense the vibration of structures. We also carried out the experimental verification about reliability of theoretical methods fur detecting the damage of a composite beam with PZT actuator and PVDF sensor. Experimental results are presented from tests on cantilevered composite beams which is damaged at different location and different dimensions. The results were compared with the simulation results. Good agreement between the results was found for the time shifts and amplitude difference in transients response of the cantilevered beam.