• 제목/요약/키워드: integrity assessment

검색결과 552건 처리시간 0.032초

F-15 기체 전투손상 수리설계 및 평가기법 사례연구 (Case Study of F-15 Airframe Battle Damage Repair Design and Assessment Procedure)

  • 김종헌;주영식
    • 한국항공우주학회지
    • /
    • 제37권1호
    • /
    • pp.105-112
    • /
    • 2009
  • 전투기가 임무수행중 기체에 발생할 수 있는 전투손상에 대처하기 위해 손상평가 및 수리설계, 구조건전성 평가방법 등 손상 후속절차를 연구하였다. 사례로서 F-15 ECS Bay에 발생한 전투손상에 대하여 ABDR(Aircraft Battle Damage Repair) 기술을 적용하여 손상평가 및 수리설계를 수행하고, 그 내용과 절차를 양식에 정리하였다. 또한, 정적강도 및 피로수명 계산과 같이 수리설계 구조의 구조건전성을 평가하여 비행안전 여부를 입증하고 영구수리 시점을 판단하였다.

Failure Probability Assessment of an API 5L X52 Gas Pipeline with a Wall-thinned Section

  • Lee Sang-Min;Yun Kang-Ok;Chang Yoon-Suk;Choi Jae-Boong;Kim Young-Jin
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권3호
    • /
    • pp.24-29
    • /
    • 2006
  • Pressurized gas pipelines are subject to harmful effects from both the surrounding environment and the materials passing through them. Reliable assessment procedures, including fracture mechanics analyses, are required to maintain their integrity. Currently, integrity assessments are performed using conventional deterministic approaches, even though there are many uncertainties to hinder rational evaluations. Therefore, in this study, a probabilistic approach was considered for gas pipeline evaluations. The objectives were to estimate the failure probability of a corroded pipeline in the gas and oil industries and to propose limited operating conditions for different types of loadings. To achieve these objectives, a probabilistic assessment program was developed using a reliability index and simulation techniques, and applied to evaluate the failure probabilities of a corroded API-5L-X52 gas pipeline subjected to internal pressures, bending moments, and combined loadings. The results demonstrated the potential of the probabilistic integrity assessment program.

플로우차트 기반 안전무결성수준 평가 절차 (Assessment Procedure of Safety Integrity Level(SIL) Based on Flowchart)

  • 김기영;고병각;장중순;천성일
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제10권2호
    • /
    • pp.107-122
    • /
    • 2010
  • Functional safety is the part of the overall safety of a system that depends on the system or equipment operating correctly in response to its inputs, including the safe management of likely operator errors, hardware failures, systematic failures, and environmental changes. One of the essential concepts of functional safety is Safety Integrity Level(SIL). It is defined as a relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction. In this paper, each element of SIL assessment will be defined. Based on each element, specific process of SIL selection will be established by using flowchart. The flowchart provides a SIL assessment guideline for functional safety engineers. The proposed theory will be verified by applying to a oil refining plant for SIL assessment.

특고압 변압기 건전성 평가에 관한 연구 (A Study on the integrity assessment of the high voltage transformer with Dissolved Gas Analysis)

  • 이일무;유상봉;정해성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1463-1464
    • /
    • 2015
  • This paper describes for the diagnosis insulating oil for transformers integrity assessment. The high-capacity oil transformer has several insulators are entered for the purpose of insulation, such as insulating oil, insulating paper and press board. Irradiated with a gas component dissolved in the insulating oil can analyze the status of the transformer, and can prevent a sudden accident in advance.

  • PDF

EN50128 SIL4 소프트웨어 프로세스 ISA 인증 사례 연구 (Study on ISA's assessment to software process for EN50128 SIL4)

  • 조치환;강찬용;황진호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.838-849
    • /
    • 2010
  • It is inevitable to control the systematic failure to obtain the software safety integrity of embedded software installed in rolling stock. Because it is not possible to assess systematic failure integrity by quantitative methods, SILs are used to group documentation, methods, tools and techniques throughout software development lifecycle which, when used effectively, are considered to provide an appropriate level of confidence in the realization of a system to a stated integrity level. Normally, safety approval process is through generic product, generic application and specification application for. For safety approval on generic application of software based system, it is required to apply the certified software processes from the planning stage for the assigned SIL. As such, we will develop project specific application with high safety integrity within time limit of contractual delivery schedule through software assessment to the modified area with the re-use of certified software module and documentation. At this point, Hyundai Rotem has developed software processes applicable to support SIL 4 based on EN50128 which was assessed and certified by TUV SUD. This paper introduces the Hyundai Rotem's detailed approach and prospective action to achieve software safety integrity level.

  • PDF

An Assessment of Reactor Vessel Integrity Under In-Vessel Vapor Explosion Loads

  • Bang, Kwang-Hyun;Cho, Jong-Rae;Park, Soo-Yong
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.299-308
    • /
    • 2000
  • A safety assessment of reactor vessel lower head integrity under in-vessel vapor explosion loads has been performed. The core melt relocation parameters were chosen within the ranges of physically realizable bounds. The premixing and explosion calculations were performed using TRACER-II code. Using the calculated explosion pressures imposed on the lower head inner wall, strain calculations were peformed using ANSYS code. Then, the calculated strain results and the established failure criteria were used in determining the failure probability of the lower head, In the explosion analyses, it is shown that the explosion impulses are not altered significantly by the uncertain parameters of triggering location and time, fuel and vapor volume fractions in uniform premixture bounding calculations. Strain analyses show that the vapor explosion-induced lower head failure is not possible under the present framework of assessment. The result of static analysis using the conservative explosion-end pressure of 50 MPa also supports the conclusion. It is recommended, however, that an assessment of fracture mechanics for preexisting cracks be also considered to obtain a more concrete conclusion.

  • PDF

퍼지의사결정을 이용한 RC구조물의 건전성평가 (Integrity Assessment for Reinforced Concrete Structures Using Fuzzy Decision Making)

  • 손용우;정영채;김종길
    • 한국전산구조공학회논문집
    • /
    • 제17권2호
    • /
    • pp.131-140
    • /
    • 2004
  • 철근콘크리트 구조물의 보수ㆍ보강 등의 유지관리를 위해서는 내구성과 내하성을 동시에 고려한 건전성평가의 의사결정기준이 절실히 요구된다. 본 논문은 CART-ANFIS을 사용하는 철근콘크리트 구조물에 대하여 효율적인 모델을 나타내었다. 철근콘크리트 구조물의 손상과 진단 등에 활용되어온 분류형 전문가시스템의 일종인 퍼지이론을 이용한 결정목 구조와 기존의 인공신경망을 이용한 결정목 구조의 건전성평가를 비교 분석한다. 손상된 철근콘크리트의 내구성 회복을 위한 보강설계 이론과 내하력 증가를 위한 보장설계 이론을 정립시켜 손상검출의 산정식을 유도하였다. 본 연구의 건전성 평가시스템 모델을 이용함으로서 보다 효율적인 철근콘크리트 유지관리 뿐만 아니라 생애주기비용 예측을 수행 할 수 있다.

충격응답을 이용한 철골 구조물 접합부의 구조건전성 모니터링 (Structural Joint Integrity Monitoring of Steel Frame Structures Using Impulse Responses)

  • 이진학;이광수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.145-150
    • /
    • 2008
  • This study proposes an improved AR-model based structural joint integrity monitoring method and a new damage sensitive feature using RMS values of impulse responses. The proposed methods were applied for joint integrity monitoring of a model scale 2-bay and 4-story steel frame structure and it was found that the AR coefficients could be more consistently estimated by adopting the band-pass filter and cross-correlation function to the raw acceleration signals and the joint damages could be successfully monitored by the proposed methods.

  • PDF

Probabilistic Structural Integrity Assessment of a Reactor Vessel Under Pressurized Thermal Shock

  • Kim, Ji-Ho;Kim, Yong-Wan;Kim, Tae-Wan;Hyung-Huh;Kim, Jong-In
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.99-107
    • /
    • 2000
  • A probabilistic integrity analysis method is presented for a reactor vessel under pressurized thermal shock(PTS) based on Monte Carlo simulation. This method can be applied to the structural integrity assessment of a reactor vessel subjected to pressurized thermal shock where the coolant temperature transient cannot be expressed explicitly as a time function. An axially or circumferentially oriented infinite length surface crack is assumed to be in the beltline weld region of the rector vessel's inside surface. The random variables are the initial crack depth, neutron fluence on the vessel's inside surface, the copper and nickel content of the vessel materials, R $T_{NDT}$ , $K_{IC}$ , and K/aub la/. The reliability of a sample reactor vessel under PTS is assessed quantitatively and the influence of the amount of neutron fluence is also examined by applying the present method.sent method.

  • PDF

교량건전성 평가의 개선을 위한 상시진동시험 (Ambient Vibration Tests for Enhanced Bridges Integrity Assessment)

  • 이진학;이종재;이창근;이원태;윤정방
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.611-614
    • /
    • 2004
  • In this study, ambient vibration tests are carried out to replace the current bridge integrity assessment using controlled vehicle test, which requires the traffic control and may induce public complains. Ambient vibration tests and output-only modal identification can be very effective approach to evaluate the bridge integrity because the ambient vibration tests can be performed very easily without trafnc control. The bridges in test road of Jungbu Inland Highway were tested and the results are discussed here.

  • PDF