• Title/Summary/Keyword: integrity assessment

Search Result 552, Processing Time 0.03 seconds

Case Study of F-15 Airframe Battle Damage Repair Design and Assessment Procedure (F-15 기체 전투손상 수리설계 및 평가기법 사례연구)

  • Kim, Jong-Heon;Joo, Young-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.105-112
    • /
    • 2009
  • For the purpose of facing battle damage that a fighter is subject to in combat, following recovery procedures such as damage assessment, repair design and structural integrity evaluation are investigated. A sample study is presented on the battle damage of F-15 ECS bay, which is comprised of damage assessment and repair design based on ABDR(Aircraft Battle Damage Repair) skills and work procedure complying with AFTO(Air Force Technical Order) forms. Further, the flight safety of repaired structure is validated and the time the permanent repair should be done is estimated through the evaluation of structural integrity such as the calculation of static strength and fatigue life.

Failure Probability Assessment of an API 5L X52 Gas Pipeline with a Wall-thinned Section

  • Lee Sang-Min;Yun Kang-Ok;Chang Yoon-Suk;Choi Jae-Boong;Kim Young-Jin
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.3
    • /
    • pp.24-29
    • /
    • 2006
  • Pressurized gas pipelines are subject to harmful effects from both the surrounding environment and the materials passing through them. Reliable assessment procedures, including fracture mechanics analyses, are required to maintain their integrity. Currently, integrity assessments are performed using conventional deterministic approaches, even though there are many uncertainties to hinder rational evaluations. Therefore, in this study, a probabilistic approach was considered for gas pipeline evaluations. The objectives were to estimate the failure probability of a corroded pipeline in the gas and oil industries and to propose limited operating conditions for different types of loadings. To achieve these objectives, a probabilistic assessment program was developed using a reliability index and simulation techniques, and applied to evaluate the failure probabilities of a corroded API-5L-X52 gas pipeline subjected to internal pressures, bending moments, and combined loadings. The results demonstrated the potential of the probabilistic integrity assessment program.

Assessment Procedure of Safety Integrity Level(SIL) Based on Flowchart (플로우차트 기반 안전무결성수준 평가 절차)

  • Kim, Gi-Young;Ko, Byeong-Gak;Jang, Joong-Soon;Chan, Sung-Il
    • Journal of Applied Reliability
    • /
    • v.10 no.2
    • /
    • pp.107-122
    • /
    • 2010
  • Functional safety is the part of the overall safety of a system that depends on the system or equipment operating correctly in response to its inputs, including the safe management of likely operator errors, hardware failures, systematic failures, and environmental changes. One of the essential concepts of functional safety is Safety Integrity Level(SIL). It is defined as a relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction. In this paper, each element of SIL assessment will be defined. Based on each element, specific process of SIL selection will be established by using flowchart. The flowchart provides a SIL assessment guideline for functional safety engineers. The proposed theory will be verified by applying to a oil refining plant for SIL assessment.

A Study on the integrity assessment of the high voltage transformer with Dissolved Gas Analysis (특고압 변압기 건전성 평가에 관한 연구)

  • Lee, Il-Moo;You, Sang-Bong;Joung, Hea-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1463-1464
    • /
    • 2015
  • This paper describes for the diagnosis insulating oil for transformers integrity assessment. The high-capacity oil transformer has several insulators are entered for the purpose of insulation, such as insulating oil, insulating paper and press board. Irradiated with a gas component dissolved in the insulating oil can analyze the status of the transformer, and can prevent a sudden accident in advance.

  • PDF

Study on ISA's assessment to software process for EN50128 SIL4 (EN50128 SIL4 소프트웨어 프로세스 ISA 인증 사례 연구)

  • Cho, Chi-Hwan;Kang, Chan-Yong;Hwang, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.838-849
    • /
    • 2010
  • It is inevitable to control the systematic failure to obtain the software safety integrity of embedded software installed in rolling stock. Because it is not possible to assess systematic failure integrity by quantitative methods, SILs are used to group documentation, methods, tools and techniques throughout software development lifecycle which, when used effectively, are considered to provide an appropriate level of confidence in the realization of a system to a stated integrity level. Normally, safety approval process is through generic product, generic application and specification application for. For safety approval on generic application of software based system, it is required to apply the certified software processes from the planning stage for the assigned SIL. As such, we will develop project specific application with high safety integrity within time limit of contractual delivery schedule through software assessment to the modified area with the re-use of certified software module and documentation. At this point, Hyundai Rotem has developed software processes applicable to support SIL 4 based on EN50128 which was assessed and certified by TUV SUD. This paper introduces the Hyundai Rotem's detailed approach and prospective action to achieve software safety integrity level.

  • PDF

An Assessment of Reactor Vessel Integrity Under In-Vessel Vapor Explosion Loads

  • Bang, Kwang-Hyun;Cho, Jong-Rae;Park, Soo-Yong
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.299-308
    • /
    • 2000
  • A safety assessment of reactor vessel lower head integrity under in-vessel vapor explosion loads has been performed. The core melt relocation parameters were chosen within the ranges of physically realizable bounds. The premixing and explosion calculations were performed using TRACER-II code. Using the calculated explosion pressures imposed on the lower head inner wall, strain calculations were peformed using ANSYS code. Then, the calculated strain results and the established failure criteria were used in determining the failure probability of the lower head, In the explosion analyses, it is shown that the explosion impulses are not altered significantly by the uncertain parameters of triggering location and time, fuel and vapor volume fractions in uniform premixture bounding calculations. Strain analyses show that the vapor explosion-induced lower head failure is not possible under the present framework of assessment. The result of static analysis using the conservative explosion-end pressure of 50 MPa also supports the conclusion. It is recommended, however, that an assessment of fracture mechanics for preexisting cracks be also considered to obtain a more concrete conclusion.

  • PDF

Integrity Assessment for Reinforced Concrete Structures Using Fuzzy Decision Making (퍼지의사결정을 이용한 RC구조물의 건전성평가)

  • 손용우;정영채;김종길
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.2
    • /
    • pp.131-140
    • /
    • 2004
  • It really needs fuzzy decision making of integrity assessment considering about both durability and load carrying capacity for maintenance and administration, such as repairing and reinforcing. This thesis shows efficient models about reinforced concrete structure using CART-ANFIS. It compares and analyzes decision trees parts of expert system, using the theory of fuzzy, and applying damage & diagnosis at reinforced concrete structure and decision trees of integrity assessment using established artificial neural. Decided the theory of reinforcement design for recovery of durability at damaged concrete & the theory of reinforcement design for increasing load carrying capacity keep stability of damage and detection. It is more efficient maintenance and administration at reinforced concrete for using integrity assessment model of this study and can carry out predicting cost of life cycle.

Structural Joint Integrity Monitoring of Steel Frame Structures Using Impulse Responses (충격응답을 이용한 철골 구조물 접합부의 구조건전성 모니터링)

  • Yi, Jin-Hak;Lee, Kwang-Soo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.145-150
    • /
    • 2008
  • This study proposes an improved AR-model based structural joint integrity monitoring method and a new damage sensitive feature using RMS values of impulse responses. The proposed methods were applied for joint integrity monitoring of a model scale 2-bay and 4-story steel frame structure and it was found that the AR coefficients could be more consistently estimated by adopting the band-pass filter and cross-correlation function to the raw acceleration signals and the joint damages could be successfully monitored by the proposed methods.

  • PDF

Probabilistic Structural Integrity Assessment of a Reactor Vessel Under Pressurized Thermal Shock

  • Kim, Ji-Ho;Kim, Yong-Wan;Kim, Tae-Wan;Hyung-Huh;Kim, Jong-In
    • Nuclear Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.99-107
    • /
    • 2000
  • A probabilistic integrity analysis method is presented for a reactor vessel under pressurized thermal shock(PTS) based on Monte Carlo simulation. This method can be applied to the structural integrity assessment of a reactor vessel subjected to pressurized thermal shock where the coolant temperature transient cannot be expressed explicitly as a time function. An axially or circumferentially oriented infinite length surface crack is assumed to be in the beltline weld region of the rector vessel's inside surface. The random variables are the initial crack depth, neutron fluence on the vessel's inside surface, the copper and nickel content of the vessel materials, R $T_{NDT}$ , $K_{IC}$ , and K/aub la/. The reliability of a sample reactor vessel under PTS is assessed quantitatively and the influence of the amount of neutron fluence is also examined by applying the present method.sent method.

  • PDF

Ambient Vibration Tests for Enhanced Bridges Integrity Assessment (교량건전성 평가의 개선을 위한 상시진동시험)

  • Yi, Jin-Hak;Lee, Jong-Jae;Lee, Chang-Geun;Lee, Won-Tae;Yun, Chung-Bang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.611-614
    • /
    • 2004
  • In this study, ambient vibration tests are carried out to replace the current bridge integrity assessment using controlled vehicle test, which requires the traffic control and may induce public complains. Ambient vibration tests and output-only modal identification can be very effective approach to evaluate the bridge integrity because the ambient vibration tests can be performed very easily without trafnc control. The bridges in test road of Jungbu Inland Highway were tested and the results are discussed here.

  • PDF