Purpose: Purpose of this study was to analyze the nursing focuses for standardization of ICU nursing records. Methods: The data were collected from 1,000days'nursing records of 197 ICU patients at a tertiary hospital in Seoul. Nursing focuses were unified at the consulting group meeting and they were cross-mapped with the NANDA nursing diagnoses. Results: The 62 nursing focuses in 7 NANDA categories were extracted from nursing record. Among total nursing focuses 41 correspond to the NANDA nursing diagnoses and 21 were added to ICU nursing focuses. The 10 most frequently used nursing focuses are 'Ineffective airway clearance', 'Impaired gas exchange', 'Ineffective tissue perfusion: cardiopulmonary', 'Ineffective breathing pattern', 'Ineffective tissue perfusion: renal', 'Ineffective infant feeding pattern', 'Risk for impaired skin integrity', 'Hyperthermia', 'Impaired skin integrity', 'Decreased cardiac output', Conclusion: Nursing focuses list of ICU was extracted from the result of this study. These nursing focuses might form a framework for development of research-based assessment guideline and care plans for ICU patients through standardization of nursing records.
Transactions of the Korean Society of Mechanical Engineers A
/
v.37
no.5
/
pp.665-671
/
2013
In a Korean Generation IV prototype sodium-cooled fast reactor (SFR), various types of high-temperature heat exchangers such as IHX (intermediate heat exchanger), DHX (decay heat exchanger), AHX (air heat exchanger), FHX (finned-tube sodium-to-air heat exchanger), and SG (steam generator) are to be designed and installed. In this study, the high-temperature design and integrity evaluation of the sodium-to-air heat exchanger AHX in the STELLA-1 (sodium integral effect test loop for safety simulation and assessment) test loop already installed at KAERI (Korea Atomic Energy Research Institute) and FHX in the SEFLA (sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger) test loop to be installed at KAERI have been performed. Evaluations of creep-fatigue damage based on full 3D finite element analyses were conducted for the two heat exchangers according to the high-temperature design codes, and the integrity of the high-temperature design of the two heat exchangers was confirmed.
As an economic, high quality, and highly reliable gear with low noise and low vibration is demanded, an overall finite element analysis regarding a gear is required. Also, an infrared thermography test, which is a quantitative testing technique, is demanded for safety and longer lifespan of gear products. In order to manufacture a gear product or to determine safety of a gear being used, it is necessary to precisely determine ingredients of a material constituting a gear and detect any internal defect. This study aims to realize a design that minimizes the spur gear displacement with respect to power during its rotation and ensures the spur gear control capacity by using a 3D model and the midasNFX program. This facilitates the assessment of the possibility of cracking by evaluating the stress intensity and focusing on the integrity of the spur gear. We prepare the specimen of the spur gear based on the possibility of cranking as per the result of the structural interpretation from an infrared ray thermal measuring technique. After cooling the spur gear, we perform experiments using thermography and halogen lamps and analyze the temperature data according to the results of the experiment. In the experiment which we use thermography after cooling, we find a rise in the temperature of the room. As a result, the defective part show temperatures lower than their surroundings while the normal parts have temperatures higher than the defective parts. Therefore, it possible to precisely identify defective part owing to its low temperature.
Transactions of the Korean Society of Mechanical Engineers A
/
v.37
no.10
/
pp.1251-1259
/
2013
In this study, high temperature design and creep-fatigue damage evaluation of a decay heat exchanger (DHX) in the decay heat removal systems of a sodium-cooled fast reactor (SFR) have been performed. Detail design and 3D finite element analysis have been conducted for the DHXs to be installed in active and passive decay heat removal systems in Korean Generation IV SFR, and the DHX installed in the STELLA-1(Sodium integral effect test loop for safety simulation and assessment) at KAERI (Korea Atomic Energy Research Institute). Evaluations of creep-fatigue damage based on full 3D finite element analyses were conducted for the two Mod.9Cr-1Mo steel heat exchangers according to the elevated temperature design codes of ASME Section III Subsection NH and RCC-MR code. Code comparisons were made based on the creep-fatigue damage evaluation and issues on conservatisms of the design codes were discussed.
In nuclear power plant, anchor bolts for pressurizer supports are sufficiently used in terms of safety reason, but field inspections have reported that some bolts exceed the limit of their allowable hardness. Because the high level of hardness may lead to failures due to the stress corrosion or fracture toughness, a regular inspection is required for the bolts in nuclear power plant. Thus, this research measures the hardness of bolts currently used in pressurizer supports and then estimates maximum allowable stresses preventing failures by stress corrosion and fracture toughness. Using the ANSYS program, the stresses of the bolts in the regular condition and accidental condition have been calculated, and the possible maximum stress has been compared with the estimated allowable stresses. From the results, the stresses of bolts in the accidental condition satisfy the allowable safety stress from the stress corrosion failure. However, in the future, it shall be needed to consider the reflection of the structure assembling method on the assembling procedure to ensure the pressurizer integrity during maintenance period time.
Lee Yoon-Hwan;Yang Joon-Eon;Kim Jong-Hoon;Kim Woon-Byung
Fire Science and Engineering
/
v.19
no.3
s.59
/
pp.20-27
/
2005
This paper evaluates the fire safety level of eight pump rooms in the nuclear power plant using a fire model, CFAST We estimate the Conditional Core Damage Probability (CCDP) of each room based on the analyzed results of CFAST Eight rooms located on the primary auxiliary building of the nuclear power plant are high pressure safety injection pump room A/B, low pressure safety injection pump room Am. containment sprdy pump room A/B, and motor-driven auxiliary feed water pump room A/B. The upper layer gas temperature of each room is estimated and the integrity of cable is reviewed. Based on the results, the integrity of the cable located at the upper part of compartment is maintained without thermal damage. The Conditional Core Damage Probability Is reduced to half of the old values. Accordingly, the fire safety assessment for eight pump rooms using the fire model will be capable of reducing the uncertainty and to develop a more realistic model.
The Korean 2nd basic plan for management of high-level radioactive waste presented a plan to manage spent nuclear fuel through dry storage facilities in NPP on-site. For the construction and operation of the facility, it is necessary to develop the monitoring system of the integrity of spent nuclear fuel before operation. NUREG-1536 recommends that the theoretical cask array, typically in the 2×10 array, should account for shadowing effect among the dry storage casks. The objective of this study was to evaluate neutron flux accounting for shadowing effect among dry storage casks. The neutron release rate was evaluated using ORIGEN based on the design basis fuel condition. And the simulation of dry storage casks and evaluation of the shadowing effect were performed using MCNP. Shadowing effect of other dry storage casks was the highest at the center of the dry storage facility of the 2×10 array compared with the outside of the cask. The shadowing effect of neutron flux on the surface among the metal casks was approximately 18% at point 1, 23% at point 2, and 43% at point 3. For the concrete casks, the shadowing effect of neutron flux on the surface was approximately 46% at point 1, 51% at point 2, and 52% at point 3. This means that correction is necessary to monitor the integrity of spent nuclear fuel in each dry storage cask through evaluation of shadowing effect. The results of this study will be used for comparative analysis of neutron measurement data from spent nuclear fuels in dry storage cask. Additionally, the neutron flux evaluation procedure used in this study could be used as the basic data of safety assessment of dry storage cask and development of safety guide.
Park, Jong-Woong;Sim, Sung-Han;Jung, Byung-Jin;Yi, Jin-Hak
KSCE Journal of Civil and Environmental Engineering Research
/
v.35
no.1
/
pp.1-8
/
2015
Wind power systems have gained much attention due to the relatively high reliability, good infrastructures and cost competitiveness to the fossil fuels. Advances have been made to increase the power efficiency of wind turbines while less attention has been focused on structural integrity assessment of structural sub-systems such as towers and foundations. Among many parameters for integrity assessment, the most perceptive parameter may be the induced horizontal displacement at the hub height although it is very difficult to measure particularly in large-scale and high-rise wind turbine structures. This study proposes an indirect displacement estimation scheme based on the combined use of inclinometers and accelerometers for more convenient and cost-effective measurements. To this end, (1) the formulation for data fusion of inclination and acceleration responses was presented and (2) the proposed method was numerically validated on an NREL 5 MW wind turbine model. The numerical analysis was carried out to investigate the performance of the propose method according to the number of sensors, the resolution and the available sampling rate of the inclinometers to be used.
Dysfunction of the inferior alveolar nerve may result from trauma, diseases or iatrogenic injury. The development and refinement of an objective method to evaluate this clinical problem is highly desirable and needed, especially concerning for an increasing medico-legal issue. Evoked potential techniques have attracted considerable attention as a means of assessing the function and integrity of nerve pathways. The purpose of this study was to characterize the Sensory Evoked Potentials(SEPs) and Somatosensory Evoked Potentials(SSEPs) elicited by electrical stimulation of mental nerve. SEPs and SSEPs were measured and analyzed statistically before and after needle injury on the inferior alveolar nerve of Sprague-Dawalye rats. Measuring SEPs was more sensitive in evaluation of the recovery of sensory function from inferior alveolar nerve injury then measuring SSEPs but we measured SSEPs in the hope of providing a safe, simple and objective test to check oral and facial sensibility, which is acceptable to the patient. We stimulated mental nerve after needle injury on the inferior alveolar nerve and SEPS on the level of mandibular foramen and SSEPs on the level of cerebral cortex were recorded. Threshold, amplitude, and latency of both of SEPs and SSEPs were analyzed. The results were as follows ; 1. Threshold of SEPs and SSEPs were $184{\pm}14{\mu}A$ and $164{\pm}14{\mu}A$ respectively. 2 SEPs were composed of 2 waves, i.e., N1 N2 in which N1 was conducted by II fibers and N2 was conducted by III fibers. 3. SSEPS were composed of 5 waves, of which N1 and N2 shower statistically significant changes(p<0.01, unpaired t-test). 4. SEPs and SSEPs were observed to be abolished immediately after local anesthesia and recovered 30 minutes later. 5. SEPs were abolished immediately after injury. N1 of SSEPs was abolished immediately and amplitued of N2 was decreased($20.7{\pm}12.2%$) immediately after 23G needle injury, but N3, N4 and N5 did not change significantly. Recovery of waveform delayed 30 minutes in SEPs and 45 minutes in SSEPs. 6. The degree of decrease in amplitude of SEPs and SSEPs, after 30G needle injury was smaller than those with 23G. SEPs recorded on the level of mandibular foramen were though to be reliable and useful in the assessment of the function of the inferior alveolar nerve after injury. Amplitude of SSEPs reflected the function and integrity of nerve and measuring them provided a safe, simple and abjective test to check oral and facial sensibility. These results suggest that measuring SEPs and SSEPs are meaningful methods for objective assessment in the diagnosis of nerve injury. N1 and N2 of SSEPs can be useful parameters for the evaluation of the nerve function following a needle injury.
The objective of this study was to describe the development and testing of an initial ecological health assessment model, based on the index of biological integrity (IBI) using fish assemblages, before establishing the final and currently used model for ecological health assessment, conservation and management of freshwater fish in Korea. The initial fish IBI model was developed during 2004~2006 and included 10 metrics, and in 2007 the final IBI 8-metric model was established for application to streams and rivers in four major Korean watersheds. In this paper, we describe how we developed fish sampling methods, determined metric attributes and categorized tolerance guilds and trophic guilds during the development of the multi-metric model. Two of the initial metrics were removed and the initial evaluation categories were reduced from six to four (excellent, good, fair, poor) before establishing the final national fish model. In the development phase, IBI values were compared with chemical parameters (BOD and COD as indicators of organic matter pollution) and physical habitat parameters to identify differences in IBI model values between chemical and physical habitat conditions. These processes undertaken during the development of the IBI model may be helpful in understanding the modifications made and contribute to creating efficient conservation and management strategies for stream environments to be used by limnologists and fish ecologists as well as stream/watershed managers.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.