• Title/Summary/Keyword: integrator

Search Result 472, Processing Time 0.022 seconds

A low power, low complexity IR-UWB receiver in multipath environments and its implementation (다중 경로 환경에 적합한 저전력 저복잡도의 IR-UWB 수신기 설계 및 구현)

  • Lee, Soon-Woo;Park, Young-Jin;Kim, Kwan-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.6 s.360
    • /
    • pp.24-30
    • /
    • 2007
  • In this paper, an energy detection-based low power, low complexity IR-UWB receiver in multipath impulse radio channel is presented. The proposed receiver has a simple 1-bit sampler for energy detection. Also, multipath signal received from multipath impulse radio channel is amplified and envelope of the signal is detected. Then, energy detection technique using integrator by summing multipath signals in certain period is adopted to minimize the BER loss by simple energy detection. In particular, in acquisition of a sample signal, SNR is additionally improved using a digital sampler. Symbol decision using several sampled signals is performed and thus the process of symbol synchronization is significantly simplified. Also, it is effectively designed to be compatible with influences of multipath and timing error. In addition, the proposed receiver complexity is reduced using pulse decision window. The performance of the proposed receiver is simulated based on IEEE 802.15.4a channel model and the algorithms are implemented on FPGA.

DEVELOPMENT OF THE 5GHZ CONTINUUM RECEIVER SYSTEM (5GHZ대 연속 전파 수신 시스템의 개발)

  • Byeon, Do-Yeong;Choi, Han-Gyu;Lee, Jeong-Won;Gu, Bon-Cheol
    • Publications of The Korean Astronomical Society
    • /
    • v.11 no.1
    • /
    • pp.109-123
    • /
    • 1996
  • We have developed a 5GHz continuum receiver system. The receiver is a direct type receiver. In order to reduce the noise due to the fluctuation of the gain in the amplifiers, the system employs the Dicke switching method. We made the 5GHz low-noise amplifier and the bandpass filter. The low-noise amplifier gives ${\sim}35dB$ gain and has ${\sim}210K$ noise temperature. The bandpass filter has a passband between 4.3 and 5.4GHz. We also made switch driver, video amplifiers, phase detector, and integrator. Using a 1.8 meter offset parabolic antenna, we measured the efficiency of the system. Since the antenna does not have a driver to track objects, observations were performed with the antenna fixed. The measured noise temperature of the system is ${\sim}650K$. From the observation of the blank sky, noise level was measured. It was found that the systematic noise(${\sim}0.5K$: peak to peak value) is much larger than the thermal noise. The systematic noise is possibly related to the stability of the DC power supplied to the receiver system. Besides the noise of the system, it was found that the airplanes are the very serious noise sources. We measured the radio flux of the Sun using the developed system. The observed radio flux of the Sun is ${\sim}10^6Jy$, which is close to the known value of the quiet Sun. The test observation of the Sun shows that the angular beam size of the antenna is ${\sim}2.2^{\circ}$.

  • PDF

The Characteristices of Step Responses of the Manabe Standard Forms and Its Application to the Controller Desegn (Manabe 표준형의 계단 응답 특성 및 제어기설계에의 응용)

  • Gang, Hwan-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.586-592
    • /
    • 1999
  • We investigate the characteristic of 소데 responses of the Manabe standard form which is used recently for design of the controller. We obtain some theorems and these theorems have the properties of the relationship between the roots of the polynomial and the stability indices which are used for the Manabe standard form. The Manabe standard form has the following properties: The sum of the squal to zero, the sum of the reciprocal of the squared roots is greater than zero and the parameter $\tau$ is the negative value of the sum of the reciprocal of the roots. We compare the step responses of the Manabe standard form with those of the ITAE form, the dead beat response and Bessel forms. We choose the 6th order closed loop polynomial and keep the same settling time for the four forms. Under these conditions we find that the Manabe standard form have faster 90% rising time than the Bessel and dead beat response. We see that the ITAE, bessel and dead beat responses have some overshoot, whereas the Manabe standard form has none. We also compare the Manabe form with the other three forms for the controller design using the pole assignment technique. If the open loop transfer function is a type-1 system (transfer functions having one integrator), then, for the closed loop system associated with the open loop transfer function, the steady state error of the unit ramp input is obtained in terms of the parameter $\tau$ of the Manabe standard form.

  • PDF

Characteristics of the Electric Fields Produced by Multiple Lightning Return Strokes (다중 낙뢰에 의해서 발생한 전장 파형의 특성)

  • 이복희;정동철;이동문
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.330-336
    • /
    • 2004
  • In this work, in order to obtain the detailed information about lightning electromagnetic pulses, the electric fields radiated from multiple lightning return strokes were measured and analyzed statistically. The electric field measuring system consists of a hemisphere antenna of 30cm in diameter, integrator and data acquisition device, and its frequency bandwidth ranges from 200Hz to 1.56MHz, and the sensitivity is 0.96㎷/V/m. The electric field signals are digitized every 200ns with the transient signal analyzer having the resolution of 12-bit and the recording length of 5 kilowords and are registered at personal computer. As a result, the electric fields produced by the first return stroke begin with a slow initial part or front, which starts just after or during the last stepped leader. On the average the rise times of the electric fields for the positive first, second and third strokes are 4.21${\mu}\textrm{s}$, 3.94${\mu}\textrm{s}$ and 2.75${\mu}\textrm{s}$, respectively, and those for the negative first, second and third strokes are 3.46${\mu}\textrm{s}$, 3.15${\mu}\textrm{s}$ and 2.79${\mu}\textrm{s}$, respectively. The zero-crossing times of the electric fields for first return strokes range from about 10 to 80${\mu}\textrm{s}$. The mean zero-crossing times for subsequent return strokes are shorter than those for first lightning return strokes.

Improvement of Unexpected Pitch Down Tendency of an Aircraft (항공기 기수 숙임 현상 개선)

  • Kim, Chong-Sup;Kwon, Hui-Man;Koh, Gi-Ok;Han, Kwang-Ho;Lee, Seung-Deok;Hwang, Byung-Moon;Kim, Seong-Jun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.162-169
    • /
    • 2011
  • The flight control system utilize RSS(Relaxed Static Stability) criteria in both longitudinal axes to achieve performance enhancements and improve stability. The aircraft using digital flight-by-wire flight control system receives aircraft flight conditions such as pitch, roll and yaw rate, normal acceleration from RSA(Rate Sensor Assembly) and ASA(Acceleration Sensor Assembly). These sensors has permissible measurement error related to system safety of an aircraft but, unexpected flight motions are happened by sensing errors such as offset, noise and etc. The unexpected pitch down tendency occurred by ASA sensor bias in 1g level flight with pilot hands-off. This paper addresses the design and verification of flight control law to improve of pitch down or up tendency caused by ASA sensor bias. The result of analysis and flight test reveals that pitch down tendency can be improved by pitch attitude feedback system.

A Study on Effects of Offset Error during Phase Angle Detection in Grid-tied Single-phase Inverters based on SRF-PLL (SRF-PLL을 이용한 계통연계형 단상 인버터의 전원 위상각 검출시 옵셋 오차 영향에 관한 연구)

  • Kwon, Young;Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.73-82
    • /
    • 2015
  • This paper proposes an ripple reduction algorithm and analyzes the effects of offset and scale errors generated by voltage sensor while measuring grid voltage in grid-tied single-phase inverters. Generally, the grid-connected inverter needs to detect the phase angle information by measuring grid voltage for synchronization, so that the single-phase inverter can be accurately driven based on estimated phase angle information. However, offset and scale errors are inevitably generated owing to the non-linear characteristics of voltage sensor and these errors affect that the phase angle includes 1st harmonic component under using SRF-PLL(Synchronous Reference Frame - Phase Locked Loop) system for detecting grid phase angle. Also, the performance of the overall system is degraded from the distorted phase angle including the specific harmonic component. As a result, in this paper, offset and scale error due to the voltage sensor in single-phase grid connected inverter under SRF-PLL is analyzed in detail and proportional resonant controller is used to reduce the ripples caused by the offset error. Especially, the integrator output of PI(Proportional Integral) controller in SRF-PLL is selected as an input signal of the proportional resonant controller. Simulation and experiment are performed to verify the effectiveness of the proposed algorithm.

Continuous Multiple Prediction of Stream Data Based on Hierarchical Temporal Memory Network (계층형 시간적 메모리 네트워크를 기반으로 한 스트림 데이터의 연속 다중 예측)

  • Han, Chang-Yeong;Kim, Sung-Jin;Kang, Hyun-Syug
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.1
    • /
    • pp.11-20
    • /
    • 2012
  • Stream data shows a sequence of values changing continuously over time. Due to the nature of stream data, its trend is continuously changing according to various time intervals. Therefore the prediction of stream data must be carried out simultaneously with respect to multiple intervals, i.e. Continuous Multiple Prediction(CMP). In this paper, we propose a Continuous Integrated Hierarchical Temporal Memory (CIHTM) network for CMP based on the Hierarchical Temporal Memory (HTM) model which is a neocortex leraning algorithm. To develop the CIHTM network, we created three kinds of new modules: Shift Vector Senor, Spatio-Temporal Classifier and Multiple Integrator. And also we developed learning and inferencing algorithm of CIHTM network.

Dual Sensing with Voltage Shifting Scheme for High Sensitivity Touch Screen Detection (고감도 터치스크린 감지를 위한 양방향 센싱과 전압쉬프팅을 이용한 센싱 기법)

  • Seo, Incheol;Kim, HyungWon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.71-79
    • /
    • 2015
  • This paper proposes a new touch screen sensing method that improves the drawback of conventional single-line sensing methods for mutual capacitance touch screen panels (TSPs). It introduces a dual sensing and voltage shifting method, which reduces the ambient noise effectively and enhances the touch signal strength. The dual sensing scheme reduces the detection time by doubling the integration speed using both edges of excitation pulse signals. The voltage shifting method enhances the signal-to-noise ratio (SNR) by increasing the voltage range of integrations, and maximizing the ADC's input dynamic range. Simulation and experimental results using a commercial 23" large touch screen show an SNR performance of 43dB and a scan rate 2 times faster than conventional schemes - key properties suited for a large touch screen panels. We implemented the proposed method into a TSP controller chip using Magnachip's CMOS 0.18um process.

Effect of Salt Concentration and Turbidity on the Inactivation of Artemia sp. in Electrolysis UV, Electrolysis+UV Processes (해수의 염 농도와 탁도가 전기, UV 및 전기+UV 공정의 Artemia sp. 불활성화에 미치는 영향)

  • Kim, Dong-Seng;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.28 no.3
    • /
    • pp.291-301
    • /
    • 2019
  • This study was conducted to investigate the effect of salt concentration and turbidity on the inactivation of Artemia sp. by electrolysis, UV photolysis, electrolysis+UV process to treat ballast water in the presence of brackish water or muddy water caused by rainfall. The inactivation at different salt concentrations (30 g/L and 3 g/L) and turbidity levels (0, 156, 779 NTU) was compared. A decrease in salt concentration reduced RNO (OH radical generation index) degradation and TRO (Total Residual Oxidant) production, indicating that a longer electrolysis time is required to achieve a 100% inactivation rate in electrolysis process. In the UV process, the higher turbidity results in lower UV transmittance and lower inactivation efficiency of Artemia sp. Higher the turbidity resulted in lower ultraviolet transmittance in the UV process and lower inactivation efficiency of Artemia sp. A UV exposure time of over 30 seconds was required for 100% inactivation. Factors affecting inactivation efficiency of Artemia sp. in low salt concentration are in the order: electrolysis+UV > electrolysis > UV process. In the case of electrolysis+UV process, TRO is lower than the electrolysis process, but RNO is more decomposed, indicating that the OH radical has a greater effect on the inactivation effect. In low salt concentrations and high turbidity conditions, factors affecting Artemia sp. inactivation were in the order electrolysis > electrolysis+UV > UV process. When the salt concentration is low and the turbidity is high, the electrolysis process is affected by the salt concentration and the UV process is affected by turbidity. Therefore, the synergy due to the combination of the electrolysis process and the UV process was small, and the inactivation was lower than that of the single electrolysis process only affected by the salt concentration.

Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site (산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현)

  • Jang, Mun-Seok;Lee, Eung-Hyuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.