• 제목/요약/키워드: integrated facility

검색결과 480건 처리시간 0.028초

공급사슬관리에서 생산입지선정 문제와 안전재고 최적화 문제의 통합모형 개발에 관한 연구 (A Study on Developing an Integrated Model of Facility Location Problems and Safety Stock Optimization Problems in Supply Chain Management)

  • 조건
    • 한국경영과학회지
    • /
    • 제31권1호
    • /
    • pp.91-103
    • /
    • 2006
  • Given a bill of materials (BOM) tree T labeled by the breadth first search (BFS) order from node 0 to node n and a general network ${\Im}=(V,A)$, where V={1,2,...,m} is the set of production facilities and A is the set of arcs representing transportation links between any of two facilities, we assume that each node of T stands for not only a component. but also a production stage which is a possible stocking point and operates under a periodic review base-stock policy, We also assume that the random demand which can be achieved by a suitable service level only occurs at the root node 0 of T and has a normal distribution $N({\mu},{\sigma}^2)$. Then our integrated model of facility location problems and safety stock optimization problem (FLP&SSOP) is to identify both the facility locations at which partitioned subtrees of T are produced and the optimal assignment of safety stocks so that the sum of production cost, inventory holding cost, and transportation cost is minimized while meeting the pre-specified service level for the final product. In this paper, we first formulate (FLP&SSOP) as a nonlinear integer programming model and show that it can be reformulated as a 0-1 linear integer programming model with an exponential number of decision variables. We then show that the linear programming relaxation of the reformulated model has an integrality property which guarantees that it can be optimally solved by a column generation method.

Pseudo-BIPV Style Rooftop-Solar-Plant Implementation for Small Warehouse Case

  • Cha, Jaesang;Cho, Ju Phil
    • International journal of advanced smart convergence
    • /
    • 제11권3호
    • /
    • pp.187-196
    • /
    • 2022
  • In this paper, we propose an example of designing and constructing a roof-type solar power plant structure equipped with a Pseudo-BIPV (Building-Integrated Photovoltaic) shape suitable for use as a roof of a small warehouse with a sandwich-type panel structure. As the characteristics of the roof-type solar power generation facility to be installed in the small warehouse proposed in this study, the shape of the roof is not a general A type, but a right-angled triangle shape with the slope is designed to face south. We chose a structure in which an inverter for one power plant and a control facility are linked by grouping several roofs of buildings. In addition, the height of the roof structure is less than 20 cm from the floor, and it has a shape similar to that of the BIPV, so it is building-friendly because it is almost in close contact with the roof. At the same time, the roof creates a reflective light source due to the white color. By linking this roof with a double-sided solar panel, we designed it to obtain both the advantage of the roof-friendliness and the advantage of efficiency improvement for the electric power generation based on the double-sided panel. Compared to the existing solar power generation facilities using A-shaped cross-sectional modules, the power generation efficiency of roofs in this case is increased by more than 11%, which we can confirm, through the comparison analysis of monitoring data between power plants in the same area. Therefore, if the roof-type solar structure suitable for the small warehouse we have presented in this paper is used, the facilities of electric power generation is eco-friendly. Further it is easier to obtain facility certification compared to the BIPV, and improved capacity of the power generation can be secured at low material cost. It is believed that the roof-type solar power generation facility we proposed can be usefully used for warehouse or factory-based smart housing. Sensor devices for monitoring, CCTV monitoring, or safety and environment management, operating in connection with the solar power generation facilities, are linked with the Internet of Things (IoT) solution, so they can be monitored and controlled remotely.

노인요양시설 요양층의 기능별 면적구성과 상관요인에 관한 연구 (A Study on the Functional Area Composition and Correlation Factors of Elderly Care Floor in Nursing Home)

  • 윤소희;김석태
    • 한국실내디자인학회논문집
    • /
    • 제24권3호
    • /
    • pp.156-164
    • /
    • 2015
  • Nursing Homes do not have a defined standard in the space area nor does it have a detailed standard facility requirement by law. This can possibly lead to the deterioration of the facility and the system. This directly affects the medical treatment space area within the nursing home. The medical treatment area provides medical treatment to seniors and this is where the seniors get most of their daily services. Therefore, this is research is about the study of the space area of the medical center and the ratio trend of the space area for the medical treatment facility located in senior nursing homes. Ten facilities have been selected in this study to analyze the correlation factors between space area and its trends. The analysis performed includes the conditions relating to the area and what affects the center. We have followed up with a proposal for improvement of the facility and area configuration for the medical treatment facility. Based on the analysis, the following conclusion can be made: First, the senior welfare centers are mostly used as a residence purpose followed a temporary stay of residence facility for the seniors. Second, research indicates that the bigger the facility, nursing and public functions took a larger portion of the space area compared to other services within the senior welfare centers. Third, the study shows the management space area took up about 1%~6% of the entire medical center within the nursing home which is a narrow space area because of the integrated management. Fourth, analysis based on the trend in the time-series indicate after the adoption of the system, there is a continued decline in the space area of nursing, management and public areas. Lastly, since before and after 2008, the space area composition of the nursing facility shows a continuous decline in our study. We can safely conclude that the revised senior welfare act's construction plan has an effect in the facility and is effectively working to meet its requirement. Therefore, the revision of the law is required to reflect the social needs of the residents.

IT융합기술을 활용한 실시간 설비진단 및 복합정보 관리시스템 설계 (Design of a Real-Time Facility Diagnosis & Complex Data Management System Using IT Convergence Technology)

  • 강문식
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권5호
    • /
    • pp.53-60
    • /
    • 2014
  • 최근 IT 기술의 급속한 발전으로 시설물의 설비진단과 관련된 융합 기술의 발전이 가속화되어 가고 있으며, 설계에서 유지, 보수 단계에 이르는 모든 관련 정보를 효율적으로 처리하고 관리할 수 있는 기법에 대한 연구가 요구되고 있다. 본 논문에서는 IT융합기술을 기반으로 설비 진단 및 시설물에 대한 복합정보를 효율적으로 처리하는 처리기법을 제안하고 실시간 복합정보 관리시스템을 설계하였다. 제안된 시스템의 성능을 평가하기 위해 특정 시설물을 대상으로 실시간 관리시스템을 설계하였으며, 결과를 분석하여 제안된 기법의 성능이 우수함을 입증하였다.

Development of Roadside Facility Management System with Video GIS Technology

  • Joo, In-Hak;Nam, Kwang-Woo;Yoo, Jae-Jun;Lee, Jong-Hun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.169-174
    • /
    • 2002
  • In this paper, we suggest a new spatial information system called video GIS where video is used for spatial data construction and is integrated with map. We develop a prototype system of video GIS and apply it to roadside facility management. The main functions supported by the suggested system are data collection, coordinate calculation and conversion, data construction, analysis, searching, and browsing. The stereo images and corresponding position data are collected by a vehicle named 4S-Van that has GPS, IMU, and cameras. The 3-D coordinates of the objects in the images, such as road sign, signal lamp, and building, can be calculated and constructed from the collected data. The spatial objects are displayed on both image and map, and can be searched and browsed, which enables visual and realistic browsing and management of spatial objects. Compared to conventional field survey used in roadside facility management, the method enables faster, easier, and more efficient construction of spatial data. The suggested video GIS can be applied not only to roadside facility management but also to many similar projects of central or local governments that are related to GIS.

  • PDF

A Study on the Development and Operation of Integrated Assessment System for National Competency Standard Professional Basic

  • Chang, Young-Hyun
    • International journal of advanced smart convergence
    • /
    • 제7권4호
    • /
    • pp.121-127
    • /
    • 2018
  • This paper develops and builds an Integrated Assessment System for National Competency Standard Professional Basic. The integrated evaluation system for basic job competency in the National Competency Standards is developed to conduct examination by means of computers, smartphones and tablet PCs. The system can be used for the basic job competency test, examination for online cyber universities, job competency examination for enterprises, and the listening, reading, and speaking test in the foreign language proficiency examination and is even better in terms of facility investment and saved operating costs as well as efficient use of spaces in comparison with conventional evaluation schemes. Even greater synergy effects can be achieved by providing support for the integrated evaluation system for basic job competency in connection with the NCS qualification system. The evaluation system has been tested and practiced at a specialized high school and can be applied to the NCS education evaluation of the college and four-year college and to the selection examination of new employees of the company.

혼합 정수 계획 모형을 활용한 서울시 폐기물 관리 시스템 예비 분석 (Preliminary Analysis of Solid Waste Management System for Seoul City by a Mixed Integer Programming Model)

  • Kim, Jae-Hee;Kim, Sheung-Kown
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2001년도 추계학술대회 논문집
    • /
    • pp.72-75
    • /
    • 2001
  • This paper presents a sophisticated mixed-integer linear programming model that may help regional decision-maker to develop long term plan of solid waste management The model revises Ni-Bin Chang(1996)'s integrated waste management models to fit Korean solid waste management system We apply this model to evaluate impact of facility sharing and coordinated operation among three self-governing districts in Seoul city Our study results indicate that facility sharing and coordinated operation among districts eliminate unnecessary landfilling and facility expansion.

  • PDF

A STUDY ON DEGREASING DETERGENT AND METHOD FOR THE IPP TEST FACILITY

  • Kim Yong-Wook;Lee Jung-Ho;Kang Sun-Il;Kim Sang-Heon;Oh Seung-Hyub
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.262-265
    • /
    • 2004
  • As a cryogen, LOx is a light blue, odorless, transparent liquid. Also it is not shock sensitive and does not decompose. However, it is a strong oxidizer and will vigorously support combustion. Therefore all harmful contaminants (such as grease, oil, fingerprint and organic materials) that could cause malfunctions, fires, or explosions in a oxygen environments must be completely removed prior to the introduction of oxygen. Especially, grease ingredient located inside of the LOx supply line, pipe and PHS (Pneumo-Hydraulic System) part can make drastic chemical reaction with oxygen. Therefore, to protect rapid reaction such as explosion, grease ingredient must be surely eliminated by a regular and irregular degreasing. Study on the availability, effectiveness and selection of degreasing detergents and method is described in this paper, and it will be useful for the construction and management of IPP test facility.

  • PDF

공동주택 유선방송설비 설치에 관한 연구 (A Study on the Establishment of Cable-TV Facility in the Apartment Complex)

  • 홍규창;이기홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1995년도 추계학술발표회논문집
    • /
    • pp.110-114
    • /
    • 1995
  • Subscriber-Unit(SU) method in apartment-housing is used as the plan for the Cable-TV(CATV) receiving facility. But it is decided to apply Notification NO.1994-18 of the Ministry of Communications regulations starting in march, 10.1994. In this study, a new plan of CATV-receiving facility according to the Notification NO.1994-18 is suggested, and it is designed to apply lone-wire from an amplifier box to a SU or another amplifier box. Proposed results adopt the Head End(HE) to introduc Integrated Service Digital Network(ISDN) and to raise added-value of apartment-housing.

  • PDF

Development of Data-Flow Control Algorithm of Wireless Network for Sewage Disposal Facility

  • Jung, Soonho;Shin, Jaekwon;Kang, Jeongjin;Lee, Seungyoun;Lee, Junghoon
    • International journal of advanced smart convergence
    • /
    • 제4권2호
    • /
    • pp.14-19
    • /
    • 2015
  • Recently, water sewage disposal facilities are able to manage real-time data collection and record management through compact broadband modem LAN switching technology. Therefore, it needs more stable and efficient facility management. So, we required practical use of environmental facilities convergence based on broadband integrated modem. In this paper, we proposed short distance wireless communication network of compact broadband modem for sewage disposal facilities. And it received data inside of water treatment facility using the two communication methods (IEEE802.11x and IEEE802.15.4x). Then, our proposed an data-flow control algorithm of wireless network technology will prioritize processing data when emergency happen through collecting data, analysis data and processing. Lastly, we proved usefulness by experiment and simulation analysis.