• Title/Summary/Keyword: integrated diagnostic system

Search Result 113, Processing Time 0.027 seconds

Development and Evaluation of Repeatability of the Integrated Constitutional Diagnosis System (통합 체질진단 시스템 개발 및 반복성 평가)

  • Jeon, Young-Ju;Kim, Jang-Woong;Kim, Jae-Uk;Bae, Jang-Han;Kim, Jong-Yeol;Kim, Keun-Ho
    • Journal of Sasang Constitutional Medicine
    • /
    • v.24 no.3
    • /
    • pp.34-41
    • /
    • 2012
  • Objectives In this study, we developed a mock-up of the system for Sasang Constitutional (SC) diagnosis. This system consists of 5 devices which are the face analyzer, the voice analyzer, the skin analyzer, the pulse analyzer, and the computer-based questionnaire. Our goal is to evaluate the repeatability of the system. Methods Each device is capable of classifying SC types. The classification probability of the integrated system for the SC types was obtained by summing the probability from each device. For evaluating the repeatability of the system, we collected data for 5 subjects, and repeated the measurement three times for each individual. The average and standard deviation were used for calculating the Coefficient of Variation. Results The results showed that the repeatability of the classification probability of the integrated system is about 8%, which implies the system is repeatable. Conclusions To increase usability of this system, it is desirable for the system to offer information on health condition of the user. The integrated constitutional diagnosis system will be upgraded to complement the convenience and to develop the diagnostic algorithm for the user's health condition.

심전도

  • 서병설
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.131-134
    • /
    • 1988
  • In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network.

  • PDF

Significance and Development of the Integrated Environment Management System Implementation (통합환경관리제도 시행의 의의와 발전방향)

  • Park, Jae Hong;Kim, Yong Seok;Lee, Won Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.3
    • /
    • pp.318-324
    • /
    • 2016
  • The significance of an integrated environmental management system implementation can be summarized into three sections. The first is that the paradigm of a permit system will be changed from the existing media-specific permits to cross-media permits. In the near future, the cross-media license will be granted based on the diagnostic results of the plant. The second is that it will be established through a social concensus, i.e., consultations with stakeholders and direct participation in the system design process of stakeholders. The third is that it will have flexibility in its operating system. In the near future, it will be possible to management an environment through its industrial workplace itself and determine if emission standards are being complied with or not through statistical methods. In addition there is also an urgent need for complementary parts in order to enhance the driving force of the integrated environmental management system which is based on transparency, reliability and flexibility. In other words, it is necessary to continuously promote in order to diffuse consensus and increase an understanding of implementation through an integrated environmental management system. It is also necessary to establish a new organization and educate authorized representatives so that they have the tools to smoothly perform the system.

A Study on Integrated Intelligent SCADA System for Industrial Facilities Management (산업설비 안전관리를 위한 지능형 원격감시 제어 통합시스템 연구)

  • 이성열
    • Journal of Intelligence and Information Systems
    • /
    • v.6 no.1
    • /
    • pp.51-64
    • /
    • 2000
  • 사회 기간산업이라 할수 있는 전기, 가스 석유등의 대단위 산업설비들은 사고 발생시 대량의 인명, 재산 피해를 가져오기 때문에 고도의 안전관리 시스템 하에서 운용되고 있다 이러한 기존 산업설비들의 안전관리는 서로 분산, 독립적인 안전관리 시스템들을 사용하고 있다 분산, 독립적인 안전관리 시스템은 산업설비에 대한 사고나 고장발생시 대부분 사람에 의존한 상황처리 작업을 수행하게 된다. 즉 사고가 발생하면 다른 안전관리 시스템들을 확인하고 그 결과를 통합하는 과정을 거처 상황처리에 대한 대책을 세우게 된다 이러한 과정은 추가적인 인력소모와 시간소모가 발생하게 되고 상황처리자의 미숙한 상황처리로 인한 사고가 발생하기도 한다. 본논문에서는 이러한 독립 안전관리 시스템의 단점을 극복하고 사고 발생시 신속, 정확하고 효율적인 상황처리를 위해 개별적인 안전관리 모니터 시스템들을 통합하는 방법을 제시한다. 또한 기존의 독립적이고 단편적인 상황추론을 국복하고자 통합된 지식베이스와 모니터 시스템들의 실시간 자료에 근거한 블랙보드 기반의 제어지식을 이용하여 종합적인 상황추론을 수행한다. 이를 위하여 각 시설물들에 대한 고장진단 시스템을 포함하는 지능형 원격감시 제어 통합시스템을 제안한다.

  • PDF

An Integrated On-Line Diagnostic System for the NORS Process of Maiden Reactor Project: The Design Concept and Lessons Learned

  • Kim, Inn-Seock
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.261-273
    • /
    • 2000
  • During an extensive review made as part of the Integrated Diagnosis System project of the Maiden Reactor Project, MOAS (Maryland Operator Advisory System) was identified as one of the most thorough systems developed thus far. MOAS is an integrated on-line diagnosis system that encompasses diverse functional aspects that are required for an effective process disturbance management: (1) intelligent process monitoring and alarming, (2) on-line sensor data validation and sensor failure diagnosis, (3) on-line hardware (besides sensors) failure diagnosis, and (4) real-time corrective measure synthesis. The MOAS methodology was used at the Maiden Man-Machine Laboratory HAMMLAB of the OECD Maiden Reactor Project. The performance of MOAS, developed in G2 real-time expert system shell for the high-pressure preheaters of the NORS process in the HAMMLAB, was tested against a variety of transient scenarios, including failures of the control valves and sensors, and tube leakage of the preheaters. These tests showed that MOAS successfully carried out its intended functions, i.e., quickly recognizing an occurring disturbance, correctly diagnosing its cause, and presenting advice on its control to the operator. The lessons learned and insights gained during the implementation and performance tests also are discussed.

  • PDF

A Fuzzy Expert System for the Integrated Fault Diagnosis (송전계통과 변전소의 통합 고장진단을 위한 퍼지 전문가 시스템)

  • Lee, Heung-Jae;Lim, Chan-Ho;Lee, Chul-Kyun;Park, Deung-Yong;Ahn, Bok-Shin
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1039-1041
    • /
    • 1998
  • This paper presents a practical fuzzy expert system to diagnose various faults occurred in local power systems. This integrated system can diagnose all faults occurred in a transmission network and substations. In this paper. the fuzzy reasoning of the diagnostic process is discussed in detail. The discrimination of false operations and non-operations of protective devices as well as the fault identification scheme are also analyzed together with the fuzzy inference process.

  • PDF

A Study on the Development of Integrated Chaos Analysis System for EEG (뇌파신호의 카오스 특징 추출을 위한 통합 시스템의 개발)

  • Woo, Yong-Ho;Kim, Hyun-Sool;Kim, Taek-Soo;Choi, Yoon-Ho;Park, Sang-Hui
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.962-964
    • /
    • 1995
  • In this paper, an integrated chaos analysis system for EEG (ICASE) is designed for the analysis of brain functions based on the chaos theory. Nonlinear dynamic characteristics of EEG such as 3-D attractor, Poincare section, correlation dimension, Lyapunov exponents and power spectrum are extracted by this system. The results show that chaotic attractors which indicate the presence of deterministic, dynamics of complex nature could be identified from a routine EEG recording for normal and pathological activity. This proves that the chaotic analysis of EEG may be an appropriate tool in the classification of brain activity and thus a possible diagnostic tool.

  • PDF

Contrivance of Integrated Pattern Differentiation Method for Diagnostic Unification of Exogenous Contagious Diseases (다양한 유행성 감염병의 진단 일원화를 위한 통합변증방법 연구)

  • Chi, Gyoo Yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • In recent years, there were frequent exogenous contagious diseases in Eastasia like SARS(severe acute respiratory syndrome), Avian influenza, Swine influenza, MERS etc. But there are various interpretations about their pathological differentiations and lead to controversy to diagnosis and medicinal use. So there needs universal and consistent understanding methods. Several conclusions are obtained from the research on differentiation theories of various epidemic diseases. Essential elements of differential diagnostic system are pathogen, characters and matters of disease and loci, especially three yin and three yang has close affinity with constitutional features or body shape. Binding these 3 categories, an integrated differentiation 3 dimensional coordinates are made. Out of these, each elements of 3 pathogen-axial lines are related with names of exogenous disease, and those of 3 feature-axial lines are related with 8 principal patterns. And those of 3 locus-axial lines implicating therapeutic method are related with steps and location of exterior and interior, 3 yin 3 yang, Defense, Qi, Nutrient and Blood, five viscera and six bowels and tissues. Additionally, 3 lines of each axis consist of factors which have their own affinity each other, so classification of pathogen, feature, locus of disease has layered interconnectedness. This classification system is included in constitutional features of individual patient. Afterwards, these cognitive structure can be used as a general theory guiding method of therapy, prevention and aftercure healthcare.

A Study on the Integrated Simulation and Condition Monitoring Scheme for a PMSG-Based Variable Speed Grid-Connected Wind Turbine System under Fault Conditions (PMSG 적용 가변속 계통연계형 풍력발전 시스템의 통합 시뮬레이션 및 스위치 개방고장 진단기법 연구)

  • Kim, Kyeong-Hwa;Song, Hwa-Chang;Choi, Byoung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.65-78
    • /
    • 2013
  • To analyze influences under open fault conditions in switching devices, an integrated simulation and condition monitoring scheme for a permanent magnet synchronous generator (PMSG) based variable speed grid-connected wind turbine system are presented. Among various faults in power electronics components, the open fault in switching devices may arise when the switches are destructed by an accidental over current, or a fuse for short protection is blown out. Under such a faulty condition, the grid-side inverter as well as the generator-side converter does not operate normally, producing an increase of current harmonics, and a reduction in output and efficiency. As an effective way for a condition monitoring of generation system by online basis without requiring any diagnostic apparatus, the estimation schemes for generated voltage, flux linkage, and stator resistance are proposed and the validity of the proposed scheme is proved through comparative simulations.

A Real-time Monitoring Agent Design for Digital Twin-based Smart Pipe Integrated Management System (디지털 트윈 기반 스마트 파이프 통합 관리 시스템을 위한 실시간 모니터링 에이전트 설계)

  • Hong, Phil-Doo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.292-294
    • /
    • 2021
  • The digital twin-based smart pipe integrated management system is an integrated solution for efficient operation and monitoring that we propose. We buried a waterway pipe underground with self-diagnostic and condition monitoring sensor functions. This pipe sends sensing data and accumulates it. Our system analyzes data to make smart decisions. The main functions of this system are remote control and monitoring. Therefore, "how to configure monitoring in real time" is a big issue. For this purpose, we designed a special real-time-based agent function. In this paper, to solve this problem, a layered architecture was proposed based on transmission points where sensor data are exchanged. An agent was placed in each layer to look at the lower layer and periodically monitor whether there were any changes in the sensor in real time. Finally, the agent system was designed and the conceptual model level was implemented to verify excellence.

  • PDF