• 제목/요약/키워드: insulation barriers

검색결과 15건 처리시간 0.029초

건설공사장 가설방음벽의 음향 특성 (Acoustic Properties of Temporary Noise Barriers on Construction Site)

  • 정진연;임정빈;이성찬
    • 한국소음진동공학회논문집
    • /
    • 제20권2호
    • /
    • pp.191-198
    • /
    • 2010
  • The noise by the construction activities is one of the main issues in Korea. To prevent the noise from construction site, construction company installs temporary noise barriers along the construction site boundary. Normally sound insulation performance ($R_w$) of the temporary noise barriers made by metal or plastic is between 18 and 31 dB and metallic noise barriers are around 5 dB higher than plastic noise barriers. Sound absorption performance (NRC) of the temporary noise barriers are between 0.20 and 0.59 so it's difficult to characterize their acoustic performance. In this study, it has founded that sound insulation performance of the temporary noise barrier has been improved about 3dB by stick the high density acoustic sheet and insertion loss of noise barrier is getting increased as the source and receiver approached the temporary noise barriers.

Hydraulic behaviour of dune sand-bentonite mixtures under confining stress

  • Gueddouda, M.K.;Lamara, M.;Abou-bekr, N.;Taibi, S.
    • Geomechanics and Engineering
    • /
    • 제2권3호
    • /
    • pp.213-227
    • /
    • 2010
  • Compacted layers of sand-bentonite mixtures have been proposed and used in a variety of geotechnical projects as engineered barriers for the enhancement of impervious landfill liners, cores of zoned earth dams and radioactive waste repository systems. This paper presents a study on the valorization of local materiel such as dune sand from Laghouat region and mine bentonite intended for the realization of liner base layers in the conception of insulation barriers for hazardous waste centers. In the practice we try to get an economical mixture that satisfies the hydraulic and mechanical properties specified by regulation rules. The effect of the bentonite additions on the mixture is reflected by its capability of clogging the matrix pores upon swelling. In order to get an adequate dune sand-bentonite mixture, an investigation on hydraulic and mechanical behaviours is carried out in this study for different mixtures. Using oedometer test, the adequate bentonite addition to the mixture, which satisfies the conditions on permeability, is found to be around 12% to 15%. These results are also confirmed by direct measurement using triaxial cell.

공동주택의 층별 도로교통 소음의 전달 특성에 관한 연구 (A Study on the Floor-Specific Characteristics of Road Traffic Noise in Apartment Buildings)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2008
  • This study is an attempt to understand the floor-specific characteristics of facade road traffic noise in apartment buildings. For this purpose, it sampled a total of seven roadside apartment building complexes: three with no soundproof bar barrier installed at roadside, one with a forest buffer zone, one with a sound-absorbing hill, and two with soundproof barriers. The measured noise level was highest on the 5th floor of apartment buildings with no soundproof barrier, and the upper stories from the 5th floor showed lower-noise measurements in order. For apartment buildings with soundproof barriers, however, the noise level was lower on the 10th floor than the 5th floor. Two apartment building groups--one with a sound-absorbing hill and the other with no soundproof barrier--showed similar measurement results in the floor-specific characteristics of facade road traffic noise. This suggests that such installations have little sound insulation effect. In the apartment building complex with a forest buffer zone around it, a slight sound insulation effect was measured on the lower floors of the buildings.

Analysis of highway reflection noise reduction using transparent noise barrier types

  • Lee, Jaiyeop;Kim, Ilho;Chang, Seoil
    • Environmental Engineering Research
    • /
    • 제20권4호
    • /
    • pp.383-391
    • /
    • 2015
  • Transparent type noise barrier is a desirable facility since it provides a secure view to drivers and passengers. However, reflection from this type of barrier could annoy dwellers on the sides of the road. To reduce reflection noise by transparent type barrier, modification can be made to the shapes on the front side and hence get effects by distortion of sound transmission. To achieve this, we have conducted simulation by which the effects of patterned screens of noise barrier on high-ways were investigated. The reduction effects of reflected sounds were evaluated for swelling, swelling with curved, rectangular and V-shaped screen type barriers, compared to the planar panel. The emitting noise was generated by 6-lane road and the patterned noise barriers had shown the reduction effects, especially in swelling and swelling with curved type for middle height dwellers, and the V-shaped screen type for higher elevation dweller. The swelling-type showed a decrease of 0.7~1.2 dB, performing the best diminution effect among the tested noise barriers.

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 (Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System)

  • 이선우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.21-28
    • /
    • 2017
  • Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summer. The purpose of this experimental study is to analyze the influence of a ventilated cavity on the insulating performance of a curtain-wall and the ventilated cavity depth and ratio of top opening needed to prevent condensation in a curtain-wall.

고속철도구간 방음벽 제진재 시험제작 및 성능평가에 관한 연구 (A Study on Sample manufacturing and Performance Evaluation for Vibration Insulation Material of Noise Barrier for High-Speed Railway)

  • 김순철;강정옥;한광섭;전병찬;한종문
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.522-529
    • /
    • 2005
  • The commercial service of KTX from April 1st 2004 has realized that whole country has shrunk into half-day life zone and it opened the times of speed. However, some technical problems unexpected before service have been raised and, among them, the noise generation at train passing was claimed by the residents living nearby the track and it is often publicized by the broadcastings and newspapers. In case where the residential area is close to the track, the installation of noise barrier at trackside is the general measures for noise reduction on bridge section and earthwork section. In case of KTX project, such measures were actually taken without any exception; however, the noise level is still high. In this study, analysis for the reason of higher noise level in spite of which the noise barriers are being installed was carried out, the sample of insulation material effective for noise barrier was manufactured and the performance of the insulation material was evaluated to verify its effectiveness

  • PDF

극저온 유체 화물창 방벽 내의 액체유동 및 기화 시뮬레이션 (LIQUID FLOW AND EVAPORATION SIMULATION OF CRYOGENIC FLUID IN THE WALL OF CRYOGENIC FLUID CARGO CONTAINMENT SYSTEM)

  • 박범진;이희범;이신형;배준홍;이경원;정왕조;안상준
    • 한국전산유체공학회지
    • /
    • 제14권2호
    • /
    • pp.9-18
    • /
    • 2009
  • The cargo containment system (CCS) for ships carrying cryogenic fluid consists of at least two levels of barriers and insulation layers. It is because, even though there is a small amount of leak through the primary barrier, the liquid tight secondary barrier blocks further leakage of the cryogenic fluid. However, once the secondary barrier is damaged, it is highly possible that the leaked cryogenic fluid flows through the flat joint made of glass wool and reaches the inner hull of the ship. The primary objective of the present study is to investigate the influence of the damage extent in the secondary barrier on the amount of leaked cryogenic fluid reaching the inner hull and the temperature distribution there. Simulation results using a computational fluid dynamics tool were compared with the experimental data for the leaked cryogenic fluid flow and evaporation in the secondary insulation layer. The experimental and computational results suggest that, unless there is a massive leak, the cryogenic fluid mostly evaporates in the insulation layer and does not reach the inner hull in the state of liquid.

A study on the barrier effect with respect to the condition of solid insulation materials in GN2

  • Lee, Hongseok;Mo, Young Kyu;Lee, Onyou;Kim, Junil;Bang, Seungmin;Kang, Jong O;Nam, Seokho;Kang, Hyoungku
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권1호
    • /
    • pp.44-47
    • /
    • 2015
  • High voltage superconducting apparatuses have been developed presently around the world under AC and DC sources. In order to improve electrical reliability of superconducting apparatuses with AC and DC networks, a study on the DC as well as the AC electrical breakdown characteristics of cryogenic insulations should be conducted for developing a high voltage superconducting apparatus. Recently, a sub-cooled liquid nitrogen cooling system is known to be promising method for developing a high voltage superconducting apparatus. A sub-cooled liquid nitrogen cooling system uses gaseous nitrogen to control the pressure and enhance the dielectric characteristics. However, the dielectric characteristics of gaseous nitrogen are not enough to satisfy the grade of insulation for a high voltage superconducting apparatus. In this case, the application of solid insulating barriers is regarded as an effective method to reinforce the dielectric characteristics of a high voltage superconducting apparatus. In this paper, it is dealt with a barrier effect on the DC and AC dielectric characteristics of gaseous nitrogen with respect to the position and number of solid insulating barriers. As results, the DC and AC electrical breakdown characteristics by various barrier effects is verified.

LNGC 2차 방벽에 적용된 Aramid 섬유의 Weibull 통계 분석을 이용한 피로특성 평가 (Estimation of Fatigue Characteristics Using Weibull Statistical Analysis with Aramid Fiber on LNGC Secondary Barrier)

  • 박진형;오동진;김민규;김명현
    • 대한조선학회논문집
    • /
    • 제54권5호
    • /
    • pp.415-420
    • /
    • 2017
  • Insulation systems in Liquefied Natural Gas Carriers (LNGC) are vulnerable to sloshing impact and fatigue loads because of waves. If gas leaks into the primary barrier, the Flexible Secondary Barrier (FSB) prevents the leakage of gas in this system. Fatigue strength of the FSB largely depends on the behavior of composite materials. In this study, a new system is applied to the FSB using aramid fiber to improve the fatigue strength of the secondary barrier, with the intention of replacing conventional E-glass fibers. The manufacturing method involved varying the ratio of the aramid fiber to the E-glass fiber for optimum design of the FSB. The fatigue tests results of the secondary barrier using aramid fiber were superior to that using E-glass fiber. The statistical analysis is performed to obtain the fatigue test results and estimate the probability of failure as well as the design guideline of LNGC secondary barriers.

Measurement of Sound Transmission Loss in a Sound Barrier Filled with the Rice-Straw Particles by the Transfer Function and Laboratory Measurement Methods

  • Kang, Chun-Won;Jang, Eun-Suk;Jang, Sang-Sik;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권4호
    • /
    • pp.338-345
    • /
    • 2018
  • The sound insulation capacity of a barrier is indicated by its transmission loss. In this study, the sound transmission loss of a sound barrier filled with rice-straw particles was measured by the transfer function method and a laboratory measurement method. The results of the two measurements were compared. The transmission losses measured by the two methods were similar above a frequency of 500 Hz. The loss increased greatly upon the introduction of a plywood to the sound barrier. The results of this study are expected to be used to design sound barriers for roads.