• Title/Summary/Keyword: insulating breakdown

Search Result 266, Processing Time 0.021 seconds

Defect Diagnosis of Cable Insulating Materials by Partial Discharge Statistical Analysis

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Jong-Yong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • Polymer insulating materials such as cross linked polyethylene (XLPE) are employed in electric cables used for extra high voltage. These materials can degrade due to chemical, mechanical and electric stress, possibly caused by voids, the presence of extrinsic materials and protrusions. Therefore, this study measured discharge patterns, discharge phase angle, quantity and occurrence frequency as well as changes in XLPE under different temperatures and applied voltages. To quantitatively analyze the irregular partial discharge patterns measured, the discharge patterns were examined using a statistical program. A three layer sample was fabricated, wherein the upper and lower layers were composed of non-void XLPE, while the middle layer was composed of an air void and copper particles. After heating to room temperature and $50^{\circ}C$ and $80^{\circ}C$ in silicone oil, partial discharge characteristics were studied by increasing the voltage from the inception voltage to the breakdown voltage. Partial discharge statistical analysis showed that when the K-means clustering was carried out at 9 kV to determine the void discharge characteristics, the amount discharged at low temperatures was small but when the temperature was increased to $80^{\circ}C$, the discharge amount increased to be 5.7 times more than that at room temperature because electric charge injection became easier. An analysis of the kurtosis and the skewness confirmed that positive and negative polarity had counterclockwise and clockwise clustering distribution, respectively. When 5 kV was applied to copper particles, the K-means was conducted as the temperature changed from $50^{\circ}C$ to $80^{\circ}C$. The amount of charge at a positive polarity increased 20.3% and the amount of charge at a negative polarity increased 54.9%. The clustering distribution of a positive polarity and negative polarity showed a straight line in the kurtosis and skewness analyses.

Fluorine Plasma Corrosion Resistance of Anodic Oxide Film Depending on Electrolyte Temperature

  • Shin, Jae-Soo;Kim, Minjoong;Song, Je-beom;Jeong, Nak-gwan;Kim, Jin-tae;Yun, Ju-Young
    • Applied Science and Convergence Technology
    • /
    • v.27 no.1
    • /
    • pp.9-13
    • /
    • 2018
  • Samples of anodic oxide film used in semiconductor and display manufacturing processes were prepared at different electrolyte temperatures to investigate the corrosion resistance. The anodic oxide film was grown on aluminum alloy 6061 by using a sulfuric acid ($H_2SO_4$) electrolyte of 1.5 M at $0^{\circ}C$, $5^{\circ}C$, $10^{\circ}C$, $15^{\circ}C$, and $20^{\circ}C$. The insulating properties of the samples were evaluated by measuring the breakdown voltage, which gradually increased from 0.43 kV ($0^{\circ}C$) to 0.52 kV ($5^{\circ}C$), 1.02 kV ($10^{\circ}C$), and 1.46 kV ($15^{\circ}C$) as the electrolyte temperature was increased from $0^{\circ}C$ to $15^{\circ}C$, but then decreased to 1.24 kV ($20^{\circ}C$). To evaluate the erosion of the film by fluorine plasma, the plasma erosion and the contamination particles were measured. The plasma erosion was evaluated by measuring the breakdown voltage after exposing the film to $CF_4/O_2/Ar$ and $NF_3/O_2/Ar$ plasmas. With exposure to $CF_4/O_2/Ar$ plasma, the breakdown voltage of the film slightly decreased at $0^{\circ}C$, by 0.41 kV; however, the breakdown voltage significantly decreased at $20^{\circ}C$, by 0.83 kV. With exposure to $NF_3/O_2/Ar$ plasma, the breakdown voltage of the film slightly decreased at $0^{\circ}C$, by 0.38 kV; however, the breakdown voltage significantly decreased at $20^{\circ}C$, by 0. 77 kV. In addition, for the entire temperature range, the breakdown voltage decreased more when sample was exposed to $NF_3/O_2/Ar$ plasma than to $CF_4/O_2/Ar$ plasma. The decrease of the breakdown voltage was lower in the anodic oxide film samples that were grown slowly at lower temperatures. The rate of breakdown voltage decrease after exposure to fluorine plasma was highest at $20^{\circ}C$, indicating that the anodic oxide film was most vulnerable to erosion by fluorine plasma at that temperature. Contamination particles generated by exposure to the $CF_4/O_2/Ar$ and $NF_3/O_2/Ar$ plasmas were measured on a real-time basis. The number of contamination particles generated after the exposure to the respective plasmas was lower at $5^{\circ}C$ and higher at $0^{\circ}C$. In particular, for the entire temperature range, about five times more contamination particles were generated with exposure to $NF_3/O_2/Ar$ plasma than for exposure to $CF_4/O_2/Ar$ plasma. Observation of the surface of the anodic oxide film showed that the pore size and density of the non-treated film sample increased with the increase of the temperature. The change of the surface after exposure to fluorine plasma was greatest at $0^{\circ}C$. The generation of contamination particles by fluorine plasma exposure for the anodic oxide film prepared in the present study was different from that of previous aluminum anodic oxide films.

V-t and Barrier Characteristics for HTS Transformer Insulation Design (고온초전도변압기 절연설계를 위한 격벽효과와 수명특성)

  • Joung, Jong-Man;Baek, Sung-Myeong;Kim, Young-Seok;Kwak, Dong-Soon;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.61-64
    • /
    • 2003
  • In the response to an increasing demand for electrical energy, much effort aimed to develop and commercialise HTS power equipments is going on around the world. For the development, it is necessary to establish the dielectric technology in $LN_2$. Hence many types of dielectric tests should be carried out to understand the dielectric phenomena at cryogenic temperature and to gather various dielectric data. Among the many types dielectric tests, the barrier effect were conducted with the simulated electrode after analysing the insulating configuration of the pancake coil type HTS transformer. The influence of a barrier on the dielectric strength was measured according to the size and the position of the barrier. It was shown that the effectiveness, the ratio of the breakdown voltage in presence of barrier to the voltage without barrier, is highest when the barrier is placed at the needle electrode side. And the barrier effect was not depend on the electrode array. The life time to breakdown with decreasing the applied voltage was increased remarkably having wide error band but the shape parameter in Weibull distribution was almost constant.

  • PDF

a-Si:H TFT Using Ferroelectrics as a Gate Insulator

  • Hur, Chang-Wu;Kung Sung;Jung-Soo, Youk;Sangook Moon;Kim, Jung-Tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05a
    • /
    • pp.53-56
    • /
    • 2004
  • The a-Si:H TFT using ferroelectric of SrTi $O_3$as a gate insulator is fabricated on glass. Dielectric characteristics of ferroelectric are superior to $SiO_2$and S $i_3$ $N_4$. Ferroelctric increases on-current, decreases thresh old voltage of TFT and also improves breakdown characteristics. The a-SiN:H has optical band gap of 2.61 eV, refractive index of 1.8~2.0 and resistivity of 10$^{13}$ - 10$^{15}$ $\Omega$cm, respectively. Insulating characteristics of ferroelectrics are excellent because dielectric constant of ferroelectric is about 60~100 and breakdown strength is over 1MV/cm. TFT using ferroelectric has channel length of 8~20${\mu}{\textrm}{m}$ and channel width of 80~200${\mu}{\textrm}{m}$. And it shows that drain current is 3.4$mutextrm{A}$ at 20 gate voltage, $I_{on}$ / $I_{off}$ is a ratio of 10$^{5}$ - 10$^{8}$ and $V_{th}$ is 4~5 volts, respectively. In the case of TFT without ferroelectric, it indicates that the drain current is 1.5 $mutextrm{A}$ at 20 gate voltage and $V_{th}$ is 5~6 volts. With the improvement of the ferroelectric thin film properties, the performance of TFT using this ferroelectric has advanced as a gate insulator fabrication technology is realized.zed.d.

  • PDF

The Electric Characteristics of the Thermal Aged Insulation-Paper with Moisture Content on the Transformer (변압기 절연지의 수분함량 및 열화에 따른 전기적 특성 연구)

  • Kim, Pil-Hwan;Kim, Ju-Han;Lee, Byung-Sung;Lee, Won-Yeong;Kim, Do-Young;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1909-1911
    • /
    • 2004
  • It is caused that insulation paper, which had got a lot of thermal stress by over-load after installation, should have been deteriorated in electrical and mechanical characteristics. Beside, insulation material is decreased the insulating property and accelerated aging of them in case of dielectric loss when transformers are manufactured with some moisture or transformers would have been them because of moisture-permeation, Therefore, in this study we experienced the influence of moisture content in case of the thermal aged insulation paper. we have measured tan ${\delta}$ and breakdown voltage in the ratio of paper' moisture content before the aging and then taken the same tests again after insulation paper thermally accelerating-aged. There is a purpose to gain data for a life-design and to establish aging mechanism in order to continuously study life expectancy of the insulation paper.

  • PDF

Electrical characteristics of class-F groundwall insulation tapes for stator windings (고정자 권선용 F종 주절연 테이프의 전기적 특성)

  • Kim, Tae-Hee;Kang, Myung-Guk;Lee, Jai-Kwun;Son, Sam-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1679-1681
    • /
    • 2004
  • Class-F and B resin-rich type insulating tapes are generally used for the ground wall insulations of respective air-cooled and water-cooled stator windings in larger turbine generators. In this paper, their electrical properties coupled with aging times in higher temperature than designed one in normal condition were experimentally investigated and the results of two comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich tapes currently used arc composed of six and a half 3-layer sheets that arc structured with mica paper, the top and bottom supports of it respectively, and the epoxy resin to bind them tightly. The results for breakdown voltage and strength on the cured specimens were presented, which were composed of the unaged, the aged accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The surface and volume resistivities on them were measured and the results are also presented to make a comparative test for the initial electrical characteristics.

  • PDF

Analysis on the Fire Accident of Vehicle Due to Damage of the Vehicle's Electrical Components (차량 전장부품 손상으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Sa, Seung-Hun;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.32-38
    • /
    • 2015
  • In this paper, we analyzed the vehicle fire accidents due to damage of vehicle's electrical components, which is applied to a vehicle. In recent development of electrical components technology, approximately 40% of vehicle manufacturing parts have applied electronic circuit technology. Phenomenon such deterioration of insulating performance or electric breakdown on the vehicle's electrical components and printed circuit boards(PCBs) resulted from moisture, contamination and aging due to repetitive operations, lead to the vehicle fire. Therefore, the application of electrical components with adequate electric capacity for vehicle and usage of molding techniques using a non-combustible materials to shut off the oxygen should be applied in order to prevent vehicle fire due to damage of the electrical components and PCBs.

High Performance Wilkinson Power Divider Using Integrated Passive Technology on SI-GaAs Substrate

  • Wang, Cong;Qian, Cheng;Li, De-Zhong;Huang, Wen-Cheng;Kim, Nam-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.3
    • /
    • pp.129-133
    • /
    • 2008
  • An integrated passive device(IPD) technology by semi-insulating(SI)-GaAs-based fabrication has been developed to meet the ever increasing needs of size and cost reduction in wireless applications. This technology includes reliable NiCr thin film resistor, thick plated Cu/Au metal process to reduce resistive loss, high breakdown voltage metal-insulator-metal(MIM) capacitor due to a thinner dielectric thickness, lowest parasitic effect by multi air-bridged metal layers, air-bridges for inductor underpass and capacitor pick-up, and low chip cost by only 6 process layers. This paper presents the Wilkinson power divider with excellent performance for digital cellular system(DCS). The insertion loss of this power divider is - 0.43 dB and the port isolation greater than - 22 dB over the entire band. Return loss in input and output ports are - 23.4 dB and - 25.4 dB, respectively. The Wilkinson power divider based on SI-GaAs substrates is designed within die size of $1.42\;mm^2$.

Chemical Properties of Insulation Paper in oil after Thermal Aging (열 열화에 따른 유입절연지의 화학적 특성)

  • Kim, Pil-Hwan;Kim, Jae-Hoon;Kim, Ju-Han;Lee, Won-Yeong;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.77-79
    • /
    • 2004
  • It is caused that insulation paper, which had got a lot of thermal stress by over-load after installation, should have been deteriorated in electrical and mechanical characteristics. Beside, insulation material is decreased the insulating property and accelerated aging of them in case of dielectric loss when transformers are manufactured with some moisture or transformers would have been them because of moisture-permeation. Therefore, in this study we experienced the influence of moisture content in case of the thermal aged insulation paper. we have measured tan 6 and breakdown voltage in the ratio of paper' moisture content before the aging and then taken the same tests again after insulation paper thermally accelerating-aged. There is a purpose to gain data for a life-design and to establish aging mechanism in order to continuously study life expectancy of the insulation paper

  • PDF

The Characteristic of Tracking Phenomena and Surface Discharge at the atmospheric Pressure (대기압하의 액체질소중 트래킹현상 및 연면방전 특성)

  • Park, Kwang-Seo;Sin, Dong-Hwa;Sin, Ho-Young;Ju, Jae-Hyun;Choi, Byoung-Ju;Lee, Kwang-Sik;Lee, Dong-In;Byon, Sung-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1699-1701
    • /
    • 1998
  • This paper was studied on the surface discharge characteristics on the solid insulators in the Liquid Nitrogen($LN_2$) at atmospheric pressure. Liquid Nitrogen has been widely used as a tooling and insulating materials for superconducting and cryogenic cable. Considering the effect of bubbles, we observed tracking Phenomena on the surface of solid insulators and investigated surface breakdown characteristics of several solid insulators.

  • PDF