• Title/Summary/Keyword: instrument and equipment

Search Result 218, Processing Time 0.038 seconds

Modeling and Control of a Four Mount Active Micro-vibration Isolation System

  • Banik, Rahul;Gweon, Dae-Gab;Hong, Dong-Pyo
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.10a
    • /
    • pp.150-153
    • /
    • 2006
  • Micro vibration isolation, typically originated from ground, is always a prime concern for the nano-measurement instruments such as Atomic Force Microscopes. A four mount active vibration isolation system is proposed in this paper. Modeling and control of such a four mount system as analyzed. Combined active-passive isolation principle is used for vibration isolation by mounting the instrument on a passively damped isolation system made of Elastomer along with the active stage in parallel that consists of very soft actuation system, the Voice Coil Motor. The active stage works in combination with the passive stage for working as a very low frequency vibration attenuator.

  • PDF

Classification of Clusters and Analysis of R&D Portfolio in Korean Industry (한국산업의 클러스터 분류 및 클러스터간 연구개발 포트폴리오 분석)

  • 박종용;신준석;박광만;김석현;박용태
    • Proceedings of the Technology Innovation Conference
    • /
    • 2002.06a
    • /
    • pp.238-256
    • /
    • 2002
  • Competitiveness of a nation can be explained by the concept of national innovation systems(NIS). As components of NIS, industry clusters become the issue in analysing innovative activity of an economy. Innovative clusters can be identified by the innovation survey or other economic activity data. Input-output Table was used widely as a tool for quantitative analysis, This paper classifies seven clusters in Korean industry based on inter-industries trade of intermediary goods and services, Maximizing procedure method is used in analysing input-output table. Identified clusters are Textiles/chemicals, Construction/Material, Instrument/Equipment, Automobile, Services, Energy, and Agriculture/Food cluster, Among these clusters, some different characteristics in R&D portfolios are detected. R&D investment characteristics of each cluster give us significant implications in understanding innovative dynamics of Korean industry.

  • PDF

IMPLEMENTATION OF DIGITAL POWER METER USING TMS320C5X

  • Ku, Bon-Hyouk;Chok, Myung-Ryul
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.575-580
    • /
    • 1998
  • A power meter is an instrument for measuring in watts the power flowing in a electric equipment. Since the value which a conventional power meter measures is analog, the power meter is hard to determine a phase difference between the voltage and current for a inductive load. The phase difference causes a loss of electric power and a increase of power-line load. In this paper, we propose a digital power meter using TI's DSP(Digital Singnal Processor) TMS320C5x, which is employed to calculate the phase difference and more accurate power consumption.

  • PDF

Evaluation on J-R Curve of 5083 aluminum Alloy Weldment by Load Ratio analysis (Load Ratio 해석에 의한 Al 5083 알루미늄합금 용접부의 J-R곡선 평가)

  • 윤한기;김연겸;우대호
    • Proceedings of the KWS Conference
    • /
    • 1997.05a
    • /
    • pp.91-98
    • /
    • 1997
  • This research is to evaluate of the J-R curve characteristic in 5083 aluminum alloy weldment by utilizing the load ratio analysis. This analysis method can be evaluated the J-R curve only with load-displacement curve without any particular precision instrument equipment in CT specimen. For validity, the results of the load ratio analysis are compared with the those of the J-R curve, which are obtained by the ASTM standard unloading compliance method. The calculated crack length of the load ratio analysis is well appropriate that the measured final crack length. And the J-R curve slope estimated by the load ratio analysis is slightly smaller than that by the ASTM unloading compliance method.

  • PDF

A Study on Surface Roughness in Wire - Cut Electric Discharge Machining (와이어 컷 방전가공(W-EDM)후의 가공면 조도 고찰)

  • 최계광;김세환
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.05a
    • /
    • pp.59-64
    • /
    • 2002
  • The effect of the numbers of processing on the punch and surface roughness of die block in the W-EDM, which is frequently used to manufacture parts of press die is studied. W-EDM equipment(Sodic A500H), the application of which has increased for its precision, is used in the process three times. To inspect the roughness of the three-time-processed dimension of the punch and the die, the surface roughness measuring instrument(System 5000 of Federal) is used.

Development of Integrated Computer Interface for Power Wheelchair User (휠체어 사용자를 위한 통합형 컴퓨터 입력장치의 개발)

  • Kim, Chang-Geol;Song, Byung-Seop
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.251-257
    • /
    • 2010
  • This paper reports a noble instrument that helps physically disabled people to access computers. There have been numerous attempts to develop such a methodology, but most of them require an additional space for workstation often including access program installation. The additional space also needs to be carefully designed to consider each specific disabled area. This study aims to develop a system that removes the spacial limitation by putting the integrated computer interface using the wheelchair controller. The implementation of the computer workstation is performed by utilizing an USB interface. The developed equipment will take an important role to support various social lives for the users and eventually to improve their quality of life.

반도체 제조공정 중 발생하는 오염입자 측정에 관한 연구

  • Na Jeong-Gil;Kim Tae-Seong
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.05a
    • /
    • pp.145-149
    • /
    • 2006
  • As the minimum feature size decreases, it is more difficult to control critical contaminant particles. For 16GB flash memory introduced by Samsung a few months ago, 50nm process was used and in this case, contaminant particles as small as 25nm should be control led. The particle beam mass spectrometer (PBMS) was developed to directly sample particles at pressures down to 100 mtorr. This instrument is sensitive to small particles (>5nm) produced in low concentrations ($>20cm^{-3}$). The PBMS has proved to be effect ive in measuring particles generated during semi-conductor fabrication processes, such as low-pressure chemical vapor deposition (LPCVD) of thin films. The operating principle of the PBMS and some measurement results are reviewed in this paper.

  • PDF

A Study on Surface Roughness in Wire-Cut Electric Discharge Machining (와이어 컷 방전가공후의 가공면 조도 고찰)

  • 김세환;최계광
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.69-73
    • /
    • 2002
  • The effect of the numbers of processing on the punch and surface roughness of die block in the W-EDM, which is frequently used to manufacture parts of press die is studied. W-EDM equipment (Sodic A500H), the application of which has increased for its precision, is used in the process three times. To inspect the roughness of the three-time-processed dimension of the punch and the die, the surface roughness measuring instrument (System 5000 of Federal) is used.

  • PDF

Scanning electron microscopic study on characteristics of tooth surface when using gracey curet and ultrasonic scaler (Gracey curet과 Ultrasonic scaler 사용 시의 치면 특성의 주사현미경적 연구)

  • Nam, Yong-Ok;Lee, Hwa-Jeong;Choi, Mi-Hye
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.635-641
    • /
    • 2016
  • Objectives: The purpose of this study is to assess the characteristics of tooth surface after using Gracy curet and Ultrasonic scaler Methods: In this study, 12 teeth extracted were used. 12 specimens were divided into three groups with the same numbers, which were classified into Control group, Gracy curet use group, and Ultrasonic scaler use group, and after performing instrument operation, we measured the roughness and the loss degree of tooth surface by using SEM. Results: In groups using Gracy curet and Ultrasonic scaler, the roughness and the loss of tooth surface increased significantly(p<0.05). In the roughness of groups using Gracy curet and Ultrasonic scaler, Ultrasonic scaler group was higher in crown, but Gracy curet group was higher in root. As a result of observation through SEM, the roughness and the loss degree increased in order of Control group, Ultrasonic scaler use group, and Gracy curet use group. Conclusions: Taken together above results, both hand instrument and ultrasound equipment create roughness and loss in crown and in root, and hand instruments makes rougher than ultrasonic instruments in root, so it is thought to require thorough and accurate technical application not to damage tooth surface when removing plaque.

A Study on Reliability Flow Diagram Development of Chemical Process Using Directed Graph Analysis Methodology (유향그래프 분석기법을 이용한 화학공정의 신뢰도흐름도 개발에 관한 연구)

  • Byun, Yoon Sup;Hwang, Kyu Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.41-47
    • /
    • 2012
  • There are PFD(Process Flow Diagram) and P&ID(Piping and Instrument Diagram) for designing and managing chemical process efficiently. They provide the operation condition and equipment specifications of chemical process, but they do not provide the reliability of chemical process. Therefore, in this study, Reliability Flow Diagram(RFD) which provide the cycle and time of preventive maintenance has been developed using Directed Graph Analysis methodology. Directed Graph Analysis methodology is capable of assessing the reliability of chemical process. It models chemical process into Directed Graph with nodes and arcs and assesses the reliability of normal operation of chemical process by assessing Directed Graph sequential. In this paper, the chemical process reliability transition according to operation time was assessed. And then, Reliability Flow Diagram has been developed by inserting the result into P&ID. Like PFD and P&ID, Reliability Flow Diagram provide valuable and useful information for the design and management of chemical process.