• 제목/요약/키워드: instantaneous heating

검색결과 37건 처리시간 0.026초

개선된 계측 및 스위칭 기법을 이용한 정전류조정 인버터 시스템 (Inverter Systems of Constant Current Regulate by Using Advanced Measurement and Switching Techniques)

  • 손진근;서일동;전희종
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.173-178
    • /
    • 2007
  • As development of industry is accelerated, most electricity load system requires power supply that could be high precision and effective control. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting & beaconing of aerodromes and electric heating system. Therefore, in this paper proposed a inverter systems of constant current regulate that using improved measurement and switching techniques. Proposed measure techniques that used moving average method of instantaneous r.m.s. for measuring current sensing improved response and precision. Also, in this paper proposed improved high effectiveness switching techniques that get high efficiency of inverter by the double-carrier modulation. Results of an experiment proved effect of proposed system.

동부 앙금 호화액의 흐름 성질 (Flow Properties of Gelatinized Cowpea Flour Dispersion)

  • 이애랑;김성곤;이신영
    • 한국식품영양과학회지
    • /
    • 제22권2호
    • /
    • pp.181-185
    • /
    • 1993
  • 동부앙금(6~9%)을 연속가열법과 순간가열법으로 각 온도(80, 85, 90, 95$^{\circ}C$)에 도달시키고 20분간 유지시킨 다음 호화액의 흐름성질을 회전점도계를 이용하여 회전속도 6~180rpm, 측정온도 6$0^{\circ}C$의 조건에서 분석하였다. 호화액은 항복응력을 가진 의가소성 유체의 성질을 보였고 각 전단속도에서의 전단응력값은 순간 가열호화액이 연속가열호화액 보다 컸다. 순간 가열호화액은 농도와 가열온도에 관계없이 연속 가열호화액보다 항복응력과 점조도 지수값이 컸고 흐름지수 값은 작았다. 점조도 지수의 대수값은 농도와 가열온도와 정의 상관관계 (p<0.05)를 보였다. 동일한 농도에서 순간 가열호화액은 연속 가열호화액보다 가열온도에 따른 점조도 지수의 대수값의 증가 속도가 컸다.

  • PDF

Microwave-assisted pretreatment technologies for the conversion of lignocellulosic biomass to sugars and ethanol: a review

  • Puligundla, Pradeep;Oh, Sang-Eun;Mok, Chulkyoon
    • Carbon letters
    • /
    • 제17권1호
    • /
    • pp.1-10
    • /
    • 2016
  • Lignocellulosic biomass conversion to biofuels such as ethanol and other value-added bio-products including activated carbons has attracted much attention. The development of an efficient, cost-effective, and eco-friendly pretreatment process is a major challenge in lignocellulosic biomass to biofuel conversion. Although several modern pretreatment technologies have been introduced, few promising technologies have been reported. Microwave irradiation or microwave-assisted methods (physical and chemical) for pretreatment (disintegration) of biomass have been gaining popularity over the last few years owing to their high heating efficiency, lower energy requirements, and easy operation. Acid and alkali pretreatments assisted by microwave heating meanwhile have been widely used for different types of lignocellulosic biomass conversion. Additional advantages of microwave-based pretreatments include faster treatment time, selective processing, instantaneous control, and acceleration of the reaction rate. The present review provides insights into the current research and advantages of using microwave-assisted pretreatment technologies for the conversion of lignocellulosic biomass to fermentable sugars in the process of cellulosic ethanol production.

自然形 太陽熱暖房裝置 에 관한 硏究 (A Study on Natural Solar Heating System)

  • 박희용
    • 대한기계학회논문집
    • /
    • 제8권6호
    • /
    • pp.553-563
    • /
    • 1984
  • 본 연구에서는 선정한 난방모델에 대하여 열회로망을 만들어 각 구성성분에 대하여 에너지평형식을 세워 시뮬레이션 모델을 구하고 여기에 경계조건과 초기조건을 대입하여 수치해석으로 푼 결과를 실측치와 비교하였다. 또한 축열벽의 열용량변화, 통기구의 개폐, 통기구에 자동온도조절 홴(fan)의 설치, 야간단열의 설치 및 온실크기 의 변화 등이 온방온도에 미치는 영향을 규명하였다.

온돌면(溫突面)의 방열량(放熱量) 산정방법(算定方法)에 관한 연구(硏究) (A Calculation Method on Heat Flux from Ondol Floor Surface)

  • 손장열;안병욱;방승기
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.173-181
    • /
    • 1989
  • Until recently there was a lack of reliable performance data for the design and operation of Ondol heating systems. This paper presents a calculation method on heat flux from Ondol floor surface. Total heat flux from floor consists of radiation and convection component. In order to analyse the characteristics of both radiation and convection heat flux, each surface temperature is measured and several temperatures near each wall are measured vertically and horizontally in a practical Ondol heating space. Radiation heat flux is calculated and analysed by Gebhart's Absorption Factor Method with the consideration of instantaneous radiant exchanges. Convection heat output is derived from the vertical temperature profiles near floor. The vertical temperature profiles could be expressed by nonlinear regression equation models and convection coefficients could be estimated by the equations. As a result, radiation, convection and total heat flux are suggested by the expression of difference between floor surface and room air temperature.

  • PDF

가변유량 밸런싱밸브를 적용한 온수 난방시스템의 유체역학적 성능 평가 (Fluid Dynamic Performance in a Hot-Water Heating System with a Variable-Flow-Rate Balancing Valve)

  • 허전;이석종;성재용;이명호
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.577-584
    • /
    • 2007
  • A variable-flow-rate balancing valve has been developed and optimized to apply to a distributor in a hot-water heating system. Fluid dynamic performance of the system was evaluated by comparing the results with the previous pressure difference control valve (PDCV) system. In view of the variations of pressure drop and flow rate according to the sequential closing of the control valves, the present system which is named "smart system distributor", is very stable without a certain flow rate concentration. The level of pressure drop variation is also low as compared with the previous system with a PDCV. In view of the occurrence of cavitation, the present system is quite superior to the previous system because the instantaneous pressures at all sections are much higher than the vapor pressure. On the other hand, the previous system has a possibility of cavitation when one or more control valves are closed.

포화상태 풀비등시 단일기포의 성장에 관한 연구 (Study on the single bubble growth at saturated pool boiling)

  • 김정배;이한춘;오병도;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1933-1938
    • /
    • 2004
  • Nucleate boiling experiments with constant wall temperature of heating surface were performed using R113 for almost saturated pool boiling conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain a constant wall temperature condition and to measure the heat flow rate with high temporal and spatial resolutions. Bubble images during the bubble growth were taken as 5000 frames a sec using a high-speed CCD camera synchronized with the heat flow rate measurements. The geometry of the bubble during growth time could be obtained from the captured bubble images. The bubble growth behavior was analyzed using the new dimensionless parameters for each growth regions to permit comparisons with previous results at the same scale. We found that the new dimensionless parameters can describe the whole growth region as initial and later respectively. The comparisons showed good agreement in the initial and thermal growth regions. The required heat flow rate for the volume change of the observed bubble was estimated to be larger than the instantaneous heat flow rate measured at the wall. Heat, which is different from the instantaneous heat supplied through the heating wall, can be estimated as being transferred through the interface between bubble and liquid even with saturated pool conditions. This phenomenon under a saturated pool condition needs to be analyzed and the data from this study can supply the good experimental data with the precise boundary condition (constant wall temperature).

  • PDF

세라믹 발열체기반 비저장식 순간 전기 온수기 개발 및 검증 (Design and Verification of Ceramic Heating Element-based Tankless Instant Electric Water Heater)

  • 안성수;김우현
    • 전자공학회논문지
    • /
    • 제53권11호
    • /
    • pp.151-159
    • /
    • 2016
  • 본 논문에서는 다량의 온수가 필요하지 않는 세면을 목적으로 개발된 세라믹 발열체 기반 비저장식 순간 전기온수기를 제안한다. 입력되는 물을 가열하여 온수로 출수시키는 히팅모듈은 유량센서를 이용하여 입력되는 물을 감지하고 세라믹 히팅 모듈을 동작시킨다. 히팅 모듈 내부는 분당 1.5리터로 입수되는 물의 온도 대비 약 $15^{\circ}C$정도로 가열된 온수로 입수 2초 내에 출수시키기 위해 1 path 유로로 설계하였고 또한 설계의 타당성을 검증하기 위해 히팅모듈 내부 물의 흐름과 온도변화에 대한 열유동해석을 수행하였다. 기본 설계를 기초로 내부에 막대형 세라믹 발열체 1개가 내장된 히팅모듈을 제작하였다. 히팅모듈 제작 후 3단계로 온도 세팅 기능을 가지는 온수기 시제품을 제작하였다. 제작된 시제품을 분당 1.5리터의 물을 공급하는 상수도관에 연결하고 출수되는 물의 온도 및 시간을 측정한 실험에서 물 공급 후 2초 후에 온수기 3단 기준으로 공급되는 물 온도 대비 $18.3^{\circ}C$로 가열된 온수를 출수할 수 있음을 확인하였다. 그리고 대기전력 1w 미만, 순간 전력도 일반가정에서의 허용범위를 넘지 않는다. 성능 측정 결과들을 통해 제안된 비저장식 순간 전기온수기가 겨울철 세면용으로 가정, 고속도로휴게소, 공장 등의 세면대에 적용이 가능함을 확인하였다.