• Title/Summary/Keyword: installation deviation

Search Result 85, Processing Time 0.023 seconds

A Study on Characteristic for a Maximum Utilization Factor of Transformer with Regard to Load Characteristics in General Customers (일반용전력사용고객 용도별 부하특성을 고려한 변압기최대이용률 비교 특성 연구)

  • Kim, Se-Dong;Wang, Yong-Peel;Hong, Hyun-Mun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.217-223
    • /
    • 2009
  • This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for 461 general customers as to AMR. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried by the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to estimate contract power with characteristics for a regression model for customers(office, store, hotel, hospital, wedding hall) which maximum utilization factor of transformer is more than 60[%].

A Study on Characteristics for a Contract Power Conversion Factor and Analysis of a Maximum Utilization Factor of Transformer in Industrial Customers (산업용전력사용고객의 변압기최대이용률과 계약전력환산율에 관한 연구)

  • Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.44-49
    • /
    • 2008
  • Contract power conversion factor which is applied to estimate contract power of industrial customers is an important standard to caculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contact power and peak power for the last 5 years of each customer for 349 industrial customers as to AMR. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried by the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is a lied to calculate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60(%).

A Study on Characteristics for a Contract Power Conversion Factor and Analysis of a Maximum Utilization Factor of Transformer in General Customers (일반용전력사용고객의 변압기최대이용률과 계약전력환산율 기준과의 비교 특성 연구)

  • Kim, Se-Dong;Wang, Yong-Peel
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.80-85
    • /
    • 2008
  • Contract power conversion factor which is applied to estimate contract power of general customers is an important standard to caculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for 461 general customers as to AMR. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried by the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to estimate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60[%].

Experiments on the Submarine Cable Protection Methods Considering the Connection Type (체결형상을 고려한 해저케이블 보호공법에 관한 실험)

  • Yoon, Jae Seon;Ha, Taemin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.329-329
    • /
    • 2017
  • In this study attempted to evaluate the stability of the protection methods by examining hydraulic characteristics of the area around the point in which marine cable protector is installed such as surf zone occurrence point of shore-end submarine cables suitable for coastal marine environmental conditions, flow rate t the tope of the protector and maximum wave height, and to provide basic data for the selection of the optimal protection method. In performing hydraulic model experiments, the topography of submarine cable installation location was reproduced in 2-D sectional channel, and models appropriate for experimental scale and similitude law were produced and installed for each condition of submarine cables and protectors. Since the topography and submarine cable protectors were reproduced and installed in 2-D sectional channel, the exact reproduction of surf and transformation in shallow water zone was possible, and thus the physical properties could be clearly analyzed. For stability review, an experiment to examine the stability was conducted using a wave maker with 50-year frequency design waves as target, and wave height and cycles were applied based on the approximate lowest low water level(Approx. L.L.W), which is the most dangerous in submarine cable protection methods. As for experimental time, typhoon passing time in summer (about 3 hours) was applied, and wave patterns and deviation ratio of the submarine cable protector were investigated after making irregular waves corresponding to design waves. In addition, current meter and wave height meter were installed at the installation location of the submarine cable protector, and the flow rates and wave height at the top of the protector were measured and analyzed to review hydraulic properties.

  • PDF

Implant Fixture Installation in the Anterior Mandible by Use of a Mucosa Supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터보조 기반 점막지지 서지컬템프레이트를 이용한 하악전치부 임플란트 식립)

  • Lee, Jee-Ho;Kim, Soung-Min;Kim, Myung-Joo;Park, Jung-Min;Seo, Mi-Hyun;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.158-165
    • /
    • 2011
  • A 73-year-old Korean female patient with a fully edentulous mandible was planned to have five implant fixtures installed in the anterior mandible for the fixed prosthesis. After 3-dimensional (3D) computed tomographic scanning was transferred to OnDemand3D$^{(R)}$ (Cybermed Co., Seoul, Korea) software program for the virtual planning, five fixtures of MK III Groovy RP implants of Branemark System$^{(R)}$ (Nobel Biocare AB Co., Goteborg, Sweden) were installed in the anterior mandible between both mental foramens using In2Guide$^{(R)}$ (CyberMed Co., Seoul, Korea) mucosa-supported surgical template with Quick Guide Kit$^{(R)}$ (Osstem Implant Co., Seoul, Korea) systems. Fixture installations were completed successfully without any complications, such as mental nerve injury, bony bleedings, fenestrations and other unexpected events. Postoperative computed tomographic scans were aligned and fused to the planned implant, then angular and linear deviations were compared with the planned virtual implants. The mean angular deviation between the planned and actual implant axes was $3.42{\pm}1.336^{\circ}$. The mean distance between the planned and actual implant at the neck area was $0.544{\pm}0.290$ mm horizontally and $0.118{\pm}0.079$ mm vertically. The average distance between the planned and actual implant at the apex area was $1.166{\pm}0.566$ mm horizontally and $0.14{\pm}0.091$ mm vertically. These results could be considered more precise and accurate than previous reports, and even our recent results. The entire procedures of this case are reported and reviewed.

A Comprehensive Model for Wind Power Forecast Error and its Application in Economic Analysis of Energy Storage Systems

  • Huang, Yu;Xu, Qingshan;Jiang, Xianqiang;Zhang, Tong;Liu, Jiankun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2168-2177
    • /
    • 2018
  • The unavoidable forecast error of wind power is one of the biggest obstacles for wind farms to participate in day-ahead electricity market. To mitigate the deviation from forecast, installation of energy storage system (ESS) is considered. An accurate model of wind power forecast error is fundamental for ESS sizing. However, previous study shows that the error distribution has variable kurtosis and fat tails, and insufficient measurement data of wind farms would add to the difficulty of modeling. This paper presents a comprehensive way that makes the use of mixed skewness model (MSM) and copula theory to give a better approximation for the distribution of forecast error, and it remains valid even if the dataset is not so well documented. The model is then used to optimize the ESS power and capacity aiming to pay the minimal extra cost. Results show the effectiveness of the new model for finding the optimal size of ESS and increasing the economic benefit.

A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control (교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF

A STUDY ON THE DIMENSIONAL ACCURACY OF MODELS USING 3-DIMENSIONAL COMPUTER TOMOGRAPHY AND 2 RAPID PROTOTYPING METHODS

  • Cho Lee-Ra;Park Chan-Jin;Park In-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.633-640
    • /
    • 2001
  • Statement of problem. Relatively low success rate of root analogue implant system was supposed to be due to the time duration between extraction and implant installation. The use of three-dimensional computer tomography and the reconstruction of objects using rapid prototyping methods would be helpful to shorten this time. Purpose. This aim of this study was to evaluate the application possibility of the 3-dimensional computer tomography and the rapid prototyping to root analogue implants. Material and methods. Ten single rooted teeth were prepared. Width and height of the teeth were measured by the marking points. This was followed by CT scanning, data conversion and rapid prototyping model fabrication. 2 methods were used; fused deposition modelling and stereolithography. Same width and height of this models were measured and compared to the original tooth. Results. Fused deposition modelling showed an enlarged width and reduced height. The stereolithography showed more exact data compared with the fused deposition modelling. Smaller standard deviation were recorded in the stereolithographic method. Overall width error from tooth to rapid prototyping was 7.15% in fused deposition modelling and 0.2% in stereolithography. Overall height showed the tendency of reducing dimensions. Conclusion. From the results of this study, stereolithography seems to be very predictable method of fabricating root analogue implant.

  • PDF

A Study on the Estimating Direct Normal Insolation Using Horizontal Global Insolation for Solar Thermal Generation System Installation in Korea (법선면 직달일사량 예측기법을 이용한 한반도에서의 태양열발전단지 건설을 위한 최적지 선정에 관한 연구)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.77-87
    • /
    • 2012
  • Images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth's surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. For the validation, estimated direct normal Insolation is compared with observed direct normal Insolation at 16 sites over the Korean peninsular from January 1982 to December 2010. Estimated direct normal Insolation shows reliable results with average deviation of -5.4 to +5.9% from the measured values and the yearly averaged direct normal Insolation of Korean peninsula was turned out to be 2.93 $kW/m^2/day$.

A Study for Optimal Design of the AIG to Improve the Performance of DeNOx Facilities Installed in Combined Cycle Plant (복합화력 탈질설비 성능향상을 위한 암모니아 주입 그리드의 최적설계 방안에 관한 연구)

  • Kim, Kwang-Chu;Park, Man-Heung;Yoon, Jun-Kyu;Lim, Jong-Han
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.811-820
    • /
    • 2007
  • A Study on the optimal design of the AIG(Ammonia Injection Grid) to improve the performance of DeNOx facilities in the HRSG(Heat Recovery Steam Generator) was performed using the CFD analysis. On the basis of the flow analysis results in the case that the AIG in the HRSG was not installed, the numerical analyses according to the positions of AIG, injection angles of nozzle and the control of ammonia injection quantity were carried out. The standard deviation according to factors was calculated for quantitative comparison. As the results, the AIG in the HRSG should be installed in the position that the uniform flow field shows through the exact flow analysis in the previous of the AIG design and installation. In the case the AIG has already been installed and non uniform flow distribution shows, it is recommended that flow correction device or KoNOx catalyst should be used. Otherwise, the control of ammonia injection angle or the ammonia injection quantity using the velocity profile analysis is demanded to accomplish the optimal performance.