• Title/Summary/Keyword: installation damage

Search Result 459, Processing Time 0.034 seconds

A Research on the Safety Condition of Power Utilities Installed on Underground Premises (지하구내 수.변전설비 안전실태 조사)

  • Jung, Jong-Wook;Jung, Jin-Soo;Yi, Geon-Ho;Kim, Young-Seok;Bae, Seok-Myung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.410-413
    • /
    • 2006
  • This paper describes the safety condition of power utilities installed on underground premises when flooding occurs. As advance preparations, the statistical data were investigated based on the rainfall trend; the flooding damage; the power utilities installation; the electric shock accidents, and domestic md foreign regulations pertaining to the power utilities installation on underground premises were also compared and analyzed. After the preliminaries, the safety condition of underground power utilities was inspected at site and the results were reflected on considering countermeasures. Based on the further studies, the regulations closely related to the underground power utilities installation can be modified.

  • PDF

Analysis of Long-Term Performance of Geogrids by Considering Interaction among Reduction Factors (감소계수 상호영향을 고려한 지오그리드의 장기성능 해석)

  • Jeon, Han-Yong;Kim, Yuan-Chun;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.7
    • /
    • pp.55-65
    • /
    • 2012
  • Total reduction factor that is used when calculating allowable tensile strength of geogrids is made by multiplying the installation damage reduction factor ($RF_{ID}$), chemical degradation reduction factor ($RF_D$), and creep reduction factor ($RF_{CR}$) etc. In case of a model estimating allowable tensile strength considering reduction factor over the short-term tensile strength of geogrids, it has a limit of not considering interaction force between reduction factors. Junction strength comes to be reduced by installation damages or chemical degradation in the same way as tensile strength. Single junction test method cannot properly test damaged samples and shows large deviations as it does not consider scale effect. Besides, regarding calculating shear strength, no reasonable study on reduction factors was conducted yet. Therefore, in this study, reduction factors that may affect the long-term performance of geogrids were revaluated considering various conditions and accurate long-term allowable tensile strength was calculated considering interrelation between reduction factors. Creep results after installation damage and chemical resistance test showed lower value than calculated value according to GRI GG-4. After the installation damage test and the chemical resistance test, the reduction factor of junction strength was less than that of tensile strength. Shear strength before and after installation damage showed no change or increase.

INSTALLATION PARAMETERS EFFECTING ON THE WIND PROOF OF A COASTAL FOREST (해안림의 방풍 효과에 영향을 미치는 설치 파라미터 분석)

  • Shin, J.H.;Chang, S.M.;Park, K.H.;Youn, H.J.
    • Journal of computational fluids engineering
    • /
    • v.20 no.2
    • /
    • pp.52-60
    • /
    • 2015
  • The objective of this research lies in the effect of installation parameters influencing on the wind proof performance of the coastal forest for damage prevention. The dissipation ratio of incident wind power is developed as an assessment index to make a lumped parameter study possible. From the real field data of East, West, and South Sea bounded on the Korean peninsula, single and double storied forests were modeled in three-dimensional shape with computer aided design, and so was done the artificial structures such as wind break, sand accumulating fence, and sand dune, etc With a commercial code ANSYS-CFX, the computational result from the comparison of dissipation ratio between single and double storied forest shows the effect of composition, and also the installation effect is investigated for artificial structures with optimal dimension of distance.

Field Application of AC High Voltage Test after Installation for EHV XLPE Power Cables (초고압 XLPE 전력케이블에 대한 설치후 교류내전압시험 현장적용)

  • Kim, Y.;Kwon, B.I.;Seong, J.K.;Han, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1768-1770
    • /
    • 2001
  • EHV power cables can take any damage during shipping, transportation, handling, storage and installation. As the damage influences a reliability of the power cable system in the short and long periods, field tests have been required, for installers, to confirm the reliability of an installed system and, for utilities, to make sure the compatibility of an installed system. Of field tests, a HV withstand test for the cable insulation has been performed to check the soundness of the insulation. For EHV XLPE power cables, the test has been done by applying a specified d.c voltage till lately. But as some problems with the d.c test is emphasized and the equipment for the a.c test is improved, the a.c test is considered positively as an after-installation test. This paper describes the recent trends of the a and its recent application in the field.

  • PDF

Heavy Rain and Flood Prevention in Urban (뉴스초점: 집중호우와 도시지역 홍수방어)

  • Jeong, Sun-Gil
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.6
    • /
    • pp.31-34
    • /
    • 2010
  • Recently, due to localized heavy rain and flash floods in urban areas is becoming more frequent flood damage. To prevent flood inundation damage, to formulate the diverse directions in connection with the drainage system of buildings, roads, sewerage, pump stations, detention (retention) pond, and streams is very important. In addition, it is important for the uniform design criteria, the consistent of hydrologic and hydraulic analysis method, and a flood disaster mitigation systems connected with structural and nonstructural measures. To accomplish this, the method such as installation of storage facilities, infiltration facilities, and underground water tank, the optimal size of the design gutter and grate of the road, ensure the capacity of pumping stations, and the installation of a flood control channel into the deep underground requires comprehensive measures dimension in urban areas.

  • PDF

A Study on the Noise Diagnosis and Suppression of the Temperature Sensor in the LCD Plant (LCD공장 내부의 온도센서 노이즈진단 및 억제에 관한 연구)

  • Kim, Kyung-Chul;Choi, Hyoung-Bum;Hwang, Young-Rok;Kim, Yong-Kwan;You, Chang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.35-41
    • /
    • 2012
  • As automation equipment and electronic device progresses, the importance of power quality is more increasing. This paper represents the analysis and suppression about the causes of trouble by the inverter's ON/OFF noise in plant in order to prevent damage resulting in a secondary damage to conduct precise diagnosis and effective noise reduction. The countermeasure as a reduced carrier frequency and the LC resonant filter had been applied and confirmed the effective results to solve the trouble of noise.

The Development of LVI Tester for WInding Deformation Measurement in Power Transformers (변압기의 권선변형 검증을 위한 LVI 시험기 개발)

  • 조국희;김광화;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.251-256
    • /
    • 2000
  • The assessment of the condition of a transformer winding which is suspected of having suffered short circuit damage can be difficult. Conventional test such as winding resistance, magnetisation current or insulation resistance will only detect damage if a permanent electrical fault exists. Visual inspection of windings necessitates the removal of oil and in many cases only a very small proportion of the winding can be seen. We describe the characteristics. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformers.

  • PDF

Development Status and Structure Design of IoT Device for Farm Management using Sound Wave (음파를 이용한 IoT 농작물 관리시스템 개발현황 및 구조설계)

  • Ghil, Min-Sik;Kwak, Dong-Kurl;Choi, Shin-Hyeong
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.278-279
    • /
    • 2018
  • Due to the frequent occurrence of dangerous wild animals in rural or mountainous areas. it has been increasing damage of crops in every year. Fight bell or electric fence is typically installed to chase those wild animals. But there are problems that it is impossible to drive out birds and spends high installation and maintenance cost. In addition, it is inefficient to the risk of electric shock effect. In this study, the proposed system can drive out hazardous wildlife and birds regardless of installation location through realtime detection with the multi-sensing based IoT platform technology. This study showed a very large significance effect that can reduce crop damage by wildlife and birds.

  • PDF

Intelligent Reclosing Scheme to reduce a Damage of Power Equipments (전력설비 피해 감소를 위한 지능형 재폐로방식에 관한 연구)

  • 임성정;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.112-117
    • /
    • 2001
  • This paper presents an intelligent reclosing scheme to reduce a damage of power equipments in power distribution systems. As the number of reclosing shot increases, an power supply reliability is improved, but an impact of electric facilities by fault currents is accumulated. The proposed scheme determines the number of reclosing shots and its intervals according to ilie magnitude of fault current. Therefore, this scherre reduces a harm of electric facilities and muntains the power supply reliability. Case studies is performd to verify the effectiveness of the proposed scheme using field operation data.

  • PDF

The Study on the Impulse Characteristic of Secondary Arresters in Power Distribution System (배전급 저압피뢰기 임펄스 특성 연구)

  • Kang, Moon-Ho;Park, Sang-Man;Park, Young-Keun;Jang, Sang-Ok;Lee, Heung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.295-297
    • /
    • 2004
  • The overvoltage generated by the lightning strokes has been doing considerable damage to the distribution network as well as the consumer facility until now. Because most of the lightning strokes are accompanied by a storm, the aftermath of damage to the consumer is so serious. Therefore it is very important to survey the optimal operation plan by the field test of distribution lightning facilities. In this paper we have accomplished the field test to verify the impulse characteristic of Secondary Arrester(SA), and analyzed the effect of the SA in power distribution system.

  • PDF