• Title/Summary/Keyword: installation damage

Search Result 461, Processing Time 0.022 seconds

Assessment of Interruption Costs on the Industry Load through Using the Microscopic Method (미시적 방법을 이용한 산업체 수용가의 공급지장비용 함수(SCDF) 산정)

  • Kim, Yong-Ha;Lee, Pyong-Ho;Kim, Young-Gil;Sin, Hyung-Chul;Oh, Seok-Hyun;Woo, Sung-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.88-96
    • /
    • 2011
  • This paper assesses interruption costs on the industry load through using the microscopic method. For assessment, the questionnaire was made on Korea Standard Industry Categorization which is composed of 28 type of industry Then, the survey was distributed to 1889 business in 12 area by staffs of KEPCO. The collected data is changed to the trustworthy data by using Bad Data Selection method and then the interruption costs of industry load was calculated by Tobit Regression which is tool analysing both collected data and the others.

A Stuty of Programmed Ignition Method for Metal Halide Lamp (메탈핼라이드 램프의 프로그램된 이그니션 방식 연구)

  • Han, Soo-Bin;Park, Suck-In;Song, Eu-Gine;Jeoung, Hak-Guen;Jung, Bong-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.181-183
    • /
    • 2009
  • This paper proposes a programmed ignition method of high frequency electronic ballast for metal halide lamp. The method precisely controls the ignition voltage and prevents possible damage of ballast for abnormal lamp operation or lamp failure, also sures the zero voltage switching. This improved performance for igniting the lamp enables reliable product of high frequency ballast because of high efficiency, fast start and no extra ignitor.

  • PDF

Development of Electric safety monitoring system for reducing the electrical fire at traditional market (재래시장 전기화재 감소를 위한 전기안전감시시스템 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.259-262
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of traditional market developed the electric safety monitoring system which is suitable in traditional market. With for this did the actual condition investigation about electrical equipment of traditional market and we constructed Test-bed for testing reliability of electric safety monitoring system. Also experiment led in Test-bed and confirmed a stability. This paper following will be used with the data for the reliability security of the electric safe system operation which follows in the traditional market actual proof equipment construction which will be advanced.

  • PDF

A Study on the Harmonics Reduction using Phase Shifting Transformer in a Electric Power Distribution System (배전계통에서 위상조정 변압기를 사용한 고조파 저감에 관한 연구)

  • 김경철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.38-44
    • /
    • 2002
  • The increasing use of non-linear loads such as power electronics draw highly distorted currents from the utility system High harmonics current, and voltages will cause equipment damage and disturb the plant operation. The application of phase shifting transformers can be a very cost-effective method of harmonic treatment where multiple harmonic sources ice in operation. In this paper simulation results used the EDSA harmonics analysis program verifying the effects of a phase shifting transformer for harmonic elimination are presented.

A Study on the Analysis of Harmonics Reduction Effects Using Single-tuned Filters In a Power System Included Power Converters (전력변환장치를 포함한 전력시스템에서 동조 필터를 이용한 고조파 저감 효과의 분석에 관한 연구)

  • 최홍규;김경철;강태은;전기원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.81-87
    • /
    • 2000
  • The increasing use of non-linear loads such as power electronics draw highly distorted currents from the utility system. High harmonics currents and voltages will cause equipment damage and disturb the plant operation. The common solution to harmonics problem is to use harmonics filters. In this paper simulation results used the EDSA harmonics analysis program verifying the effects of the single-tuned filter for harmonic elimination are presented.

  • PDF

Fluid-elastic Instability Evaluation of Steam Generator Tubes

  • Cho, Young Ki;Park, Jai Hak
    • International Journal of Safety
    • /
    • v.11 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • It has been reported that the plugged steam generator tube of Three Mile Island Unit 1 in America was damaged by growing flaw and then this steam generator tube destroyed the nearby steam generator tubes of normal state. On this account, stabilizer installation is necessary to prevent secondary damage of the steam generator tubes. The flow-induced vibration is one of the major causes of the fluid-elastic instability. To guarantee the structural integrity of steam generator tubes, the flow-induced vibration caused by the fluid-elastic instability is necessary to be suppressed. In this paper, the effective velocity and the critical velocity are calculated to evaluate the fluid-elastic instability. In addition, stability ratio value of the steam generator tubes is evaluated in order to propose one criterion when to determine stabilizer installation.

The Development of Surge Protection Circuit Applying SCR for Improving Reliability (신뢰도 향상을 위해 SCR을 응용한 서지 보호회로 개발)

  • NamKoong, Up;Chu, Kwang-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.96-101
    • /
    • 2012
  • A surge protection device of the metal oxide varistor(MOV) has been commonly used for preventing electrical damage in many electronic equipments. The MOV has a property that leakage current is increased and might be permanently damaged when it is exposed continuously to the electrical stresses such as lightening surges. In this paper, we propose a novel surge protection circuit adopting a silicon controlled rectifier(SCR) in the traditional protection circuits using the MOV device simultaneously. When lightning surges are injected to the proposed circuit, the MOV lets the surge pulses bypassing through the ground at first up to the level that SCR begins to operate. Above the threshold level of turning on the SCR, the SCR operates bypasses large surge currents to the ground. Proposed circuit was verified with a leakage current experiment and PSpice circuit simulations under the repeated surge injection environment.

A Study on Reliability Analysis for Reliability Testing & Field Degradation Data of LED Lighting (LED조명기기의 필드 열화데이터에 대한 신뢰성 분석에 관한 연구)

  • Yang, Seong-Yong;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.54-59
    • /
    • 2011
  • LED lightings typically do not fail catastrophically during use. However, over time the light output will gradually depreciate. Even if there are same LED lighting, they are so different at all. because of dissimilar the use and environment of each LED lighting. In this paper, we make a description of reliability analysis procedures for the degradation data using collected field data. Reliability analysis procedures are consisted of estimating degradation models and failure time, verification of distribution and parameters of the distribution, and reliability measures estimation. At some point in time, the light emitted from an LED lightings depreciates to a level where it is no longer considered adequate for a specific application.

Development of a 3-D Visualization Application for Management of Substation Equipment

  • Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.38-44
    • /
    • 2009
  • This paper presents a new windows application based on 3-D graphics and Text-To-Speech (TTS) for effective management of substation equipment. When problems in a power system occur, inexperienced power system operators may have difficulty in understanding the situation as well as finding suitable countermeasures quickly. This paper addresses an effective scheme to visualizing power system equipment under normal and abnormal conditions using 3-D graphics and animations. In addition, the state variations and the order of maintenance priority of substation equipment are represented by TTS and intuitive methods. The proposed system can help power system operators to more quickly understand the state of power system equipment, and it can provide operators with the suitable countermeasures for minimizing damage caused by equipment problems.

The Development of a Flood Protection System for Pad Transformers Using Pneumatic Pressure in Areas Prone to Floods

  • Kim, Gi-Hyun;Lee, Jae-Yong;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.3
    • /
    • pp.27-32
    • /
    • 2010
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown areas and low-lying shores by torrential rain, typhoons and tsunamis. It has, in turn, caused replacement, social and economic costs for blackouts. For activity management regarding flood damage we produced a flood protection system which using the Pad transformer as a basic frame and is developed using pneumatic pressure. We tested safety concerns including insulation resistance and current leakage first for water tank flooding and, second, by an empirical test through supplying 22.9[kV]. We estimate that costs associated with flooding and power failure can be diminished by these advances toward creating a more reliable system.