• 제목/요약/키워드: insolation

검색결과 386건 처리시간 0.025초

2상 2중 승압형 쵸퍼에 의한 태양전지의 최대출력추적제어 (Maximum Power Tracking Control of Photo-voltaic using the Two Phase with Combined for Step-up Chopper)

  • 오동섭;박윤석;이승환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.3-6
    • /
    • 2001
  • This paper is shows the configuration of the maximum power tracking control of Photo-voltaic and battery charge system. Up to now, the chopper system had the problem which a battery become a short life by reason of discontinuity of output current and its energy reduce. But in this paper, We propose the chopper system which maintain the successive output current and at the same time, control the maximum output location by change time-ratio using tracking of energy variation that occur because of the varied volume of insolation per a day and temperature.

  • PDF

절연노화 애자의 실시간 감지를 위한 신경회로망의 개발 (Neural Networks for Real-time detecting of Energized Insulator)

  • 김종만;김원섭;김형석;신동용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2276-2279
    • /
    • 2002
  • For detecting of Energized Insulator, a new Lateral Information Propagation Networks(LIPN) has been proposed. Faulty insulator is reduced the rate of insolation extremely, and taken the results dirty and injured. It is necessary to be actions that detect the faulty insulator and exchange the new one. And thus, we have designed the LIPN to be detected that insulators by the real time computation method through the inter-node diffusion. In the network, a node corresponds to a state in the quantized input space. Each node is composed of a processing unit and fixed weights from its neighbor nodes as well as its input terminal. Information propagates among neighbor nodes laterally and inter-node interpolation is achieved. Through the results of simulation experiments, we define the ability of real-time detecting the faulty insulators.

  • PDF

태양광에너지 측정을 통한 우리나라 주요 도시의 Global Dimming 현상 분석에 관한 연구 (대기의 청명도 분석을 중심으로) (A Study on the Analysis of Global Dimming Appearances Using the Solar Radiation Measurement in Korean Major Cities (Focused on Atmospheric Clearness Analysis))

  • 조덕기;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.45-52
    • /
    • 2007
  • Since the atmospheric clearness index is main factor for evaluating global-dimming of atmosphere environment, it is necessary to estimate its characteristics all over the major cities in Korea. We have begun collecting clearness index data since 1982 at 16 different cities and considerable effort has been made for constructing a standard value from measured data at each city. The new clearness data for global-dimming analysis will be extensively used by evaluating atmospheric environment as well as by solar PV application system designer or users. From the results, we can conclude that 1) Yearly mean 61.9% of the atmospheric clearness index was evaluated for clear day all over 2) A significant difference of atmospheric clearness index is observed between 1982-1989 and 1990-1997, 1998-2005 through 16 different cities in Korea.

접시형 태양열 집광 시스템의 에너지 분포 특성에 관한 연구 (A Study on Energy Distributions Produced by Dish Solar Concentrating System)

  • 현성택;강용혁;천원기
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.907-913
    • /
    • 2002
  • An experimental study on energy density distributions produced by dish solar concentrating system was performed to optimally design and rightly position a cavity receiver. This deemed also very useful to find and correct various errors associated with a concentrator. It is observed that the actual focal length is 2.17 m with a maximum energy density of 1.89 MW/$m^2$. By evaluating the position of flux centroid, it was found that there are errors within 2 cm from the target center. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06 m radius. The area concentration ratio normalized to 800 W/$m^2$ insolation and 90% mirror reflectivity was 347 suns. The total integrated power of 2467 W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%.

EPSB 콘크리트의 공학적 특성에 미치는 골재 종류의 영향에 대한 기초적 연구 (A Fundamental Study on the Influence of Types of Aggregate on the Engineering Properties of EPSB Concrete)

  • 김하석;최선미;강철;곽은구;정갑철;김진만
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.453-456
    • /
    • 2005
  • The use of lightweight concrete products is usually increased at a recently high structures. Among the rest EPSB concrete products which have an excellence on the sound and thermal insolation are used. Also, the gathering of nature aggregate is limited, so that lack of fine aggregate is appearing. The purpose of this study is to obtain basic data of properties of EPSB concrete in according to types of aggregate. The results of experiment are as follow. The EPSB concrete using bottom ash is appeared the lowest slump in fresh concrete. The EPSB concrete using river sand and bottom ash are showed as a similar compressive strength except it using crushed sand in hardened concrete.

  • PDF

옥외 관측을 통한 EVA, POE PV모듈의 열화 연구 (Outdoor Testing and Degradation of EVA and POE Encapsulated Photovoltaic Modules)

  • 김제하
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.847-852
    • /
    • 2016
  • Using both EVA and POE encapsulants, we fabricated polycrystalline Si PV modules and performed a set of reliability tests of PID, DH, TC, and Complex prior to outdoor installation. The power output with temperatures and insolation as well as I-V characteristics had been monitored under outdoor environments for 18 months. In the entire period, the total power of 3,576 kWh from POE PV modules was observed larger than 3,449 kWh from EVA PV modules by 3.5%. All the PV modules showed a 5.6~9.2% drop in the conversion efficiency. As for the solar power generation, the PV modules performed through PID, TC test revealed distinct difference in between EVA and POE for which the POE PV module produced more power by +11.4% and +6.6%, respectively, as measured in the 18th month. In addition, POE was proved to protect better the solar cells under PID influence.

태양전지를 이용한 Water Pumping 시스템 적용에 대한 연구 (Study on Water Pumping System using PV Array)

  • 최성호;조정민;이승환;이상집;김성남;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1251-1253
    • /
    • 2000
  • This paper describes control of water pumping system using PV array. An integral part of the system with various system components be constructed PV array. maximum power point tracker BLDC motor and pump. BLDC motor has the quality of torque output and efficiency, has been more widely used in a field for multifarious application. However pumping system using PV array has limited for application because output characteristics of solar cell are greatly fluctuate on the variations of insolation, temperature and loads. For this reson, in this paper each parts efficiently contoroled by the maximum power point tracker, the vector control method of BLDC motor and the pressure PI controller using TMS320C- 31.

  • PDF

PV용 Solar cell의 MPPT 시뮬레이션에 관한 연구 (A Study On The Maximum Power Point Tracking Simulation of Photovoltaic Solar Cell)

  • 정병호;이강연;조금배;백형래
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집
    • /
    • pp.17-20
    • /
    • 2004
  • PV model is presented based on the shockley diode equation. The simple model has a photo-current source, an single diode junction and a series resistance and includes temperature dependences. An accurate PV module electrical model is presented, matching with boost converter MPPT strategy and demosntarted in Matlab for a typical general purpose solar cell. Given solar insolation and temperature, the model returns current vector and MPP.

  • PDF

건물(建物) 외벽(外壁)의 전열특성(傳熱特性) 평가(評價)에 관한 실측(實測) 연구(硏究) - 단열재 위치에 따른 실험용 건물의 겨울철 열특성 평가를 중심으로 - (Experimental Study on the Evaluation of Heat Transfer Characteristics of Buildings' External Walls -Focusing on the winter heat transfer characteristics of four experimental model buildings in accordance with the location of insulation-)

  • 손장열;윤동원;박재형
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.228-234
    • /
    • 1989
  • This paper describes the experimental thermal performance results of four experimental model buildings insulated differently. For the purpose of examining the thermal characteristics of external walls and indoor thermal conditions, four experimental model buildings are constructed as externally insulated, internally insulated, non-insulated &light-weight curtain wall types with different K-values and heat capacities, respectively.
    Through the measurements of temperatures at various points and solar insolation, the effects of insulation and heat capacities are evaluated, and the evaluated effects of each experimental model buildings are compared. Hence, the characteristics of temperature profiles, time-lag effects and decrement factors are discovered.

  • PDF

전면형 이중외피의 절기별 운용성능 분석 (Analysis for Seasonal Operation Performance of Multistory Facade)

  • 임혜진;조수;성욱주;임상훈;한찬훈
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.111-120
    • /
    • 2012
  • In this study, to present the data in the internal thermal condition of Double skin facade were measured internal temperature and inlet and outlet openings wind speed of double skin facade. Measurements were similar to temperatures in the upper double skin facade. Especially in summer, temperature stratification is through to be unfulfilled seamlessly despite inlet and outlet openings open. Double skin facade inlet and outlet openings of the air flow rate was slower outlet openings of the air flow rate than inlet openings of the air flow rate.