• Title/Summary/Keyword: inner temperature

Search Result 1,409, Processing Time 0.028 seconds

Fabrication Development of Stainless Steel - cast Iron Dual Tube (스테인리스강-주철 이중복합관의 제조개발에 관한 연구)

  • Choi, Sang-Ho;Kang, Choon-Sik
    • Journal of Korea Foundry Society
    • /
    • v.8 no.4
    • /
    • pp.429-436
    • /
    • 1988
  • The influences of some casting conditions on bonding ratio and state at bonding zone of stainless steel-cast iron dual tube produced by centrifugal casting process were investigated to estimate fabrication technics. 1) Bonding ratio is increasing such as increasing of inner surface temperature of outer metal(stainless steel STS 304), if pouring temperature of inner metal (cast iron) is constant. 2) The more pouring temperature of inner metal (cast iron) increase, the more bonding ratio increase when inner surface temperature of outer metal (cast iron) is constant. 3) As the mold rotary speed is increase, the hatching area of bonding map (perfect bonding area) goes down to the low pouring temperature of inner metal. 4) In order to predict bonding state of two different metal, we are able to make and use the bonding map about casting conditions such as inner surface temperature of outer metal, pouring temperature of inner metal and mold rotary speed.

  • PDF

Effects of Shoe Sizes on the Inner Environment of Shoes (신발사이즈가 신발 내적환경(內的環境)에 미치는 영향(影響))

  • Yoo, Hyun;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.6 no.4
    • /
    • pp.151-162
    • /
    • 2002
  • This study aims to reveal the effects of shoe size room on the inner environment of shoes by examining the changes of footskin temperature, temperature and humidity of the shoes, and psychological responses. The following conclusions were made: 1. Skin temperature had significant differences according to shoe sizes in the inner foot parts (right/left) and the outer foot part (left). As time went, skin temperature was distributed as follows: Type A > Type C > Type B. 2. Skin temperature appeared in the following order: instep > inner foot > outer foot. 3. The temperature within the shoes had significant differences: Type A > Type C > Type B. But no significance was recognized in the humidity within the shoes: Type B > Type C > Type A. 4. Some significance was noticed in the psychological responses of size fitness and comfortableness. In size fitness, Type B was responded to be fitting, Type A little small, and Type C rather big. Moisture had similar changes according to three shoe sizes, but humid was the response as time went. Comfortableness appeared in the order of Type C > Type B > Type A.

A Study on Calculating the Temperature Distributions in the Concrete members of Reinforced Concrete Building with Fire Damage (철근콘크리트조 화재건물의 부재내부온도분포 추정에 관한 연구)

  • 오창희
    • Fire Science and Engineering
    • /
    • v.1 no.1
    • /
    • pp.11-18
    • /
    • 1987
  • This study is for calculating the equation of the inner temperature in the concrete, mainly by the theory or heat conduction in the solid. The results are as follow ; 1. The equation of the Fourier's heat diffusion is used formally to get the distribution of inner temperature or the concrete members, and this is programed by using the computer. 2. As study in the past, heat constant of concrete is calculated for function of temperature described recommendation heat constant value in comparison with the existing inner heating experimental result.

  • PDF

Thermal System Analysis for Optimization of Torch Position in The Core Making Machine. (중자조형기의 토치위치 최적화를 위한 열계해석)

  • 한근조;안성찬;심재준;한동섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.587-590
    • /
    • 2000
  • The new core making method economized on core sand requested. The new method is heating core box until it reaches reasonable temperature and then spraying core sand with core binder into core box. Inner temperature distribution have to uniform in order to form core of uniform thickness. Therefore, in this study we treat of inner temperature distribution of core box in priority. First, determine proper torch number. Next, optimize the torch position to minimize the average of absolute deviation(AVEDEV) of inner temperature. The results are as followed : 1. The torch number that makes inner temperature distribution about $300^\circ{C}$ uniformly is 25. 2. When $S_H$ and $S_V$ is 0.7, the torch position is optimized and AVEDEV is 5.85.

  • PDF

Quantitative Analysis of the Condensation Characteristics with Solar Radiations and Inner Temperature of the Tilted Box (일사량과 경사진 육면체 내부의 온도변화에 따른 응축특성에 관한 정량적 연구)

  • Lee, Cheun-Gi;Koh, Young-Ha;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.44-50
    • /
    • 2011
  • The solar radiation, inner temperature of the tilted box and the amount of condensed water were measured to find the most effective purified water production system. The inner temperature of the tilted box was related with solar radiation that was affected by sunshine and cloud. With analyzing those relationships of the solar radiation, inner box temperature, the angle of tilted boxes and amounts of water condensation optimal collecting system area could be calculated.

A Numerical Study on Sectional Temperature Distribution and Heat Recovery Amount of Passive Ventilation Skin (패시브환기외피의 단면온도분포 및 열회수량에 관한 수치해석적 연구)

  • Lee, Tae-Cheol;Son, Yu-Nam;Yoon, Seong-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.705-710
    • /
    • 2012
  • This study aims to analyse changes of inner temperature of PVS(Passive ventilation skin) and heat recovery when it has ventilation of air through PVS using numerical simulation in the winter condition. Results are as follows. 1) In case of the air inflows through PVS, change of inner temperature of PVS is lower than in case of the air flows inner space to out space, by dynamic insulation. 2) It was identified that the temperature gradient of PVS were bigger by increases of ventilation amount. To reduce ventilation load, heat transfer efficiency at the inner side of PVS is important and what performance of insulation at the inner side of PVS secure helps to improve heat performance of all PVS.

Development of Ultra-high Capacitance MLCC through Low Temperature Sintering (저온소결을 통한 초고용량 MLCC 개발)

  • Sohn, Sung-Bum;Kim, Hyo-Sub;Song, Soon-Mo;Kim, Young-Tae;Hur, Kang-Heon
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.2
    • /
    • pp.146-154
    • /
    • 2009
  • It is necessary to minimize the thickness of Ni inner electrode layer and to improve the coverage of inner electrode, for the purpose of developing the ultra high-capacity multi layered ceramic capacitor (MLCC). Thus, low temperature sintering of dielectric $BaTiO_3$ ceramic should be precedently investigated. In this work, the relationship between dielectric properties of MLCC and batch condition such as mixing and milling methods was investigated in the $BaTiO_3$(BT)-Dy-Mg-Ba system with borosilicate glass as a sintering agent. In addition, several chip properties of MLCC manufactured by low temperature sintering were compared with conventionally manufactured MLCC. It was found that low temperature sintered MLCC showed better DC-bias property and lower aging rate. It was also confirmed that the thickness of Ni inner electrode layer became thinner and the coverage of inner electrode was improved through low temperature sintering.

An Investigation on Surgical Parameters for the Treatment of Intervertebral Disc during Electrothermal Therapy (디스크의 전기열치료시 수술변수에 관한 연구)

  • Jin E.D.;Choi J.S.;Tack G.R.;Lee B.S.;Lee B.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.513-514
    • /
    • 2006
  • Recently intradiscal electrothermal therapy is introduced, which is a new and minimally invasive technique fer the treatment of discogenic low back pain. This procedure involves the percutaneous threading of a flexible catheter into the disc under fluoroscopic guidance. The catheter, composed of thermal resistive coil, heats the posterior annulus of the disc, causing contraction of collagen fibers and destruction of afferent nociceptors. This study tries to investigate the effects of the important factors of this procedure such as heat source temperature and heat applying time on the temperature distribution within the intervertebral disc. This study utilized both computer simulation and the experiment for the verification of finite element analysis. FE analysis was carried out with ANSYS v7.0 (ANSYS Inc, USA) using 10,980 number of brick element and 12,551 number of node. The functional spinal units of 5 month old swine were used for the experiment and the temperature was monitored using 10 channel temperature measurement device MV200. Through this study, it was able to analyze the temperature range of inner intervertebral disc by two mechanisms which are known to alleviate pain clinically. The results showed that when the heat source temperature was kept up 80 degree for 1,020 seconds, the temperature of inner annulus reached at 45 degree up to the distance of 15.6mm from heat source, which explains coagulation of inner annulus by heat. When the same heat source was used, the temperature of inner nucleus reached at 60 degree up to the distance of 9mm from heat source, which explains contraction of inner nucleus by heat.

  • PDF

Modeling of the Safety Distance between Defrost Heater and Plastic Inner Wall of Refrigerator (제상 히터와 냉장고 플라스틱 내벽 사이의 안전거리에 대한 모델링)

  • Jung, Young;Shin, Jong-Min;Tikhonov, Alexei V.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • Two dimensional modeling was carried out to find the safety distance between the defrost heater and the plastic inner wall of domestic refrigerator Estimation was processed for the three cases; the estimation of plastic wall temperature (1) without any protection, (2) with an aluminum foil attached on a wall, and (3) with an aluminum shield installed between heater and wall. The former two cases are found to be dangerous during defrosting process, because the temperatures of inner wall reach above 80'C , which is the upper temperature limit of the wall material. The case with an aluminum shield is considered to be safe by maintaining the temperature of the wall in the range of 6$0^{\circ}C$ during defrosting process.

Effects of Fin Configuration on the Evaporator Performance (휜 형상에 따른 증발기의 전열 성능)

  • Lee, Jin Ho;Kwon, O Kap
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.1
    • /
    • pp.27-36
    • /
    • 1990
  • An experimental investigation was made to study the performance characteristics of evaporator having different fin configurations and tube inner grooves. Three different types of fin such as super slitted fin, slitted fin, plain fin, and two types of tube such as inner grooved tube, and bare tube, are tested varying the air velocity, evaporation temperature and superheat of refrigerant. Results show that in the range of air side Reynolds number $3{\times}10^3\;-\;1.5{\times}10^4$ evaporator with super slitted fin and inner grooved tube shows best performance. It is 80% higher in overall heat transfer coefficient and 2.6 times higher in pressure loss compared to that with plain fin inner grooved tube. Friction factor is found to be almost independent of evaporating temperature and degree of superheat, while Colburn j factor varies with evaporating temperature.

  • PDF