• Title/Summary/Keyword: inlet pressure

Search Result 1,649, Processing Time 0.027 seconds

Numerical Study of Pulsatile Blood Flow in Stenotic Artery (협착 동맥에서의 맥동 혈류 유동에 대한 수치해석적 연구)

  • Seo, Tae-Won;Buriev, Bahtiyor
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.891-896
    • /
    • 2008
  • In the present computational study, simple stenotic artery models using pulsatile flow condition were investigated. A 1 Hz non-reversing sinusoidal velocity for pulsatile flow was imposed at the flow inlet and the corresponding Womersley number based on the vessel radius is 2.75. The simple stenotic geometries have been used that consist of 25%, 50% and 75% semicircular constriction in a cylindrical tube. In this paper, numerical solutions are presented for a first harmonic oscillatory flow using commercial software ADINA 8.4. As stenosis and Reynolds number increase, the maximum wall shear stress(WSS) increases while the minimum WSS decreases. As the stenotic rate increases, the pressure drop at the throat severely decreases to collapse the artery and plaque. It is found that the fluid mechanical disturbances due to the constriction were highly sensitive with rate of stenosis and Reynolds number. When Reynolds number and stenosis increase, the larger recirculation region exists. In this recirculation region the possibility of plaque attachment is increasingly higher. The present results enhance our understanding of the hemodynamics of a stenotic artery.

Study on Performance and Optimal Operating Conditions of Regenerative Steam-Injection Gas Turbine Systems (증기분사 재생 가스터빈 시스템의 성능 및 최적 운전조건에 관한 연구)

  • Kim, Kyoung-Hoon;Kim, Dong-Joo;Park, Sang-Hee;Oh, Man-Soo;Kim, Dong-Myoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.1
    • /
    • pp.29-39
    • /
    • 2010
  • The system performance of the regenerative gas-turbine cycle with the steam injection into the combustor has been studied through the thermodynamic cyclic analysis. The effects of the pressure ratio, the steam injection ratio, the ambient temperature, and the turbine inlet temperature are investigated on the thermal efficiency, the fuel consumption, and the specific power as well as the operating conditions for the maximum thermal efficiency of the system. The results of the present analysis find that the use of steam injection in the regenerative gas-turbine system can greatly enhance the thermal efficiency and the specific power of the system.

Experimental Study to Investigate the Flow Characteristics of a Supersonic Turbine Depending on the Relative Positions of Nozzle and Cascade (노즐과 익렬의 상대 위치에 따른 초음속 터빈의 유동특성에 대한 실험적 연구)

  • Cho, Jong-Jae;Kim, Kui-Soon;Jeong, Eun-Hwan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.3
    • /
    • pp.30-38
    • /
    • 2010
  • Experiments were performed to investigate the flow characteristics of a partial admission supersonic turbine depending on the relative positions of nozzle and cascade. The flow was visualized by a Schlieren system. The static pressures at the turbine cascade inlet, passage and outlet were measured by pressure transducers. Highly complicated flow patterns including shocks, nozzle-cascade interaction and shock boundary layer interactions of the supersonic turbine were observed by the experiments. And the flow characteristics in the supersonic turbine as the relative positions were observed.

Numerical Study on the Evaporation Flow Phenomena of Natural Refrigerant CO2 through Small Diameter Tubes (천연냉매인 이산화탄소의 세관 유동시 발생하는 증발 유동 현상에 대한 수치해석 연구)

  • Choi, In-Su;Park, Byung-Duck
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • For the environment protection, carbon dioxide as a natural refrigerant has been studied to use in an automotive air conditioning system. Hence, a numerical model has been developed to describe the evaporation phenomena of carbon dioxide flowing through very small diameter tubes. The two dimensional low-Reynolds $k-{\varepsilon}$ model was used to predict the flow phenomena of carbon dioxide in the two phase during its evaporation. Furthermore, the results obtained from the model were compared with the experiments for the validation. The heat transfer coefficient is lower, as the tube inner diameter becomes smaller. However, the amount of heat absorbed by a unit mass of carbon dioxide is greater due to more surface area. Therefore, the small diameter tube has advantage in terms of compact design of evaporator. When the inlet condition of pressure and temperature is low, the heat transfer coefficient is slightly high at the same size of tube because of the thermal properties of carbon dioxide.

  • PDF

Development of Multi Sample Array System Based on Pneumatic Valve (공압식 미세밸브를 이용한 다중유체 배열장치 개발)

  • Kim, Chul Min;Park, Seo Jung;Kim, Gyu Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.1
    • /
    • pp.59-63
    • /
    • 2017
  • We present a multi-sample array device based on a pneumatic system. Solenoid valves were used to control a micro valve in a pneumatic system. The use of a compressor together with a vacuum pump ensured that one outlet could supply both compression and vacuum pressure. The multi-sample array device was fabricated using conventional photolithography and PDMS casting. The device was composed of a multiplexer, sample array, and rinsing. The multiplexer could control four sample solutions injecting into the sample array chamber. Sample solution not arrayed was removed by DI-water from the rinsing inlet. To prevent trapping of microbubbles in the channel during injection of sample solution into the device, surfactant was added in PDMS solution to serve as a hydrophilic surface treatment. As a result, the device could be used as a sample array for 64 cases, using four samples and three columns of three chambers.

Effects of Working Fluids on the Performance Characteristics of Organic Rankine Cycle (ORC) Using LNG Cold Energy as Heat Sink (LNG 냉열을 열싱크로 이용하는 유기랭킨사이클(ORC)의 작동유체에 따른 성능 특성)

  • Kim, Kyoung Hoon;Ha, Jong Man;Kim, Kyung Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.2
    • /
    • pp.200-208
    • /
    • 2014
  • This paper presents thermodynamic performance analysis of organic Rankine cycle (ORC) using low temperature heat source in the form of sensible energy and using liquefied natural gas (LNG) as heat sink to recover the cryogenic energy of LNG. LNG is able to condense the working fluid at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the mathematical model, a parametric analysis is conducted to examine the effects of eight different working fluids, the turbine inlet pressure and the condensation temperature on the system performance. The results indicate that the thermodynamic performance of ORC such as net work production or thermal efficiency can be significantly improved by the LNG cold energy.

Performance Characteristics of a Combined Regenerative Ammonia-Water Based Power Generation Cycle Using LNG Cold Energy (LNG 냉열을 이용하는 암모니아-물 복합 재생 동력 사이클의 성능 특성)

  • Kim, Kyounghoon;Oh, Jaehyeong;Jeong, Youngguan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.510-517
    • /
    • 2013
  • The ammonia-water based power generation cycle utilizing liquefied natural gas (LNG) as its heat sink has attracted much attention, since the ammonia-water cycle has many thermodynamic advantages in conversion of low-grade heat source in the form of sensible energy and LNG has a great cold energy. In this paper, we carry out thermodynamic performance analysis of a combined power generation cycle which is consisted of an ammonia-water regenerative Rankine cycle and LNG power generation cycle. LNG is able to condense the ammonia-water mixture at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the thermodynamic models, the effects of the key parameters such as source temperature, ammonia concentration and turbine inlet pressure on the characteristics of system are throughly investigated. The results show that the thermodynamic performance of the ammonia-water power generation cycle can be improved by the LNG cold energy and there exist an optimum ammonia concentration to reach the maximum system net work production.

Thermodynamic Performance Characteristics of Organic Rankine Cycle (ORC) using LNG Cold Energy (LNG 냉열을 이용하는 유기랭킨사이클(ORC)의 열역학적 성능 특성)

  • Kim, Kyoung Hoon;Ha, Jong Man;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.41-47
    • /
    • 2014
  • In this work a thermodynamic performance analysis is carried out for a combined cycle consisted of an organic Rankine cycle (ORC) and a LNG cycle. The combined system uses a low grade waste heat in the form of sensible energy and the LNG cold energy is used for power generation as well as for heat sink. The effects of the key parameters of th system such as turbine inlet pressure, condensation temperature and source temperature on the characteristics of system are throughly investigated. The simulation results show that the thermodynamic performance of the combined system can be significantly improved compared to the normal ORC which is not using the LNG cold energy.

Lip Type Electromagnetic Flap Valve for Low Leakage (누수 최소화를 위한 립 타입 전자력 플랩 밸브)

  • Lim, In-Ho;Lee, Ki-Jung;Sim, Woo-Young;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1476-1477
    • /
    • 2008
  • This paper reports on a flexible flap valve actuated by electromagnetic force under a constant pressure source. The flexible flap valve consists of the three main components: a flexible flap with a steel disk embedded in PDMS, an electromagnetic actuator and two glass plates with inlet and outlet. Sealing lip structures for improving the valve characteristics are added on the outlet of the bottom glass substrate. The flap valve is fabricated by the spin-coating process, the EDM process, SU-8 mold process and oxygen plasma treatment. The dimension of an assembled flap valve is $12mm{\times}20mm{\times}28mm$. The stroke volume of the flap valve is measured for various pressures and open times. When the input voltage of 30 V is applied for 0.33 s, the minimum stroke volume of the flap valve is 70 ${\mu}L$ at 50 kPa.

  • PDF

Numerical Simulation of Three-Dimensional Motion of Droplets by Using Lattice Boltzmann Method

  • Alapati, Suresh;Kang, Sang-Mo;Suh, Yong-Kweon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.2-5
    • /
    • 2008
  • This study describes the numerical simulation of three-dimensional droplet formation and the following motion in a cross-junction microchannel by using the Lattice Boltzmann Method (LBM). Our aim is to develop the three-dimensional binary fluids model, consisting of two sets of distribution functions to represent the total fluid density and the density difference, which introduces the repulsive interaction consistent with a free-energy function between two fluids. We validated the LBM code with the velocity profile in a 3-dimensional rectangular channel. Then, we applied our code to the numerical simulation of a binary fluid flow in a cross-junction channel focusing on the investigation of the droplet formulation. Due to the pressure and interfacial-tension effect, one component of the fluids which is injected from one inlet is cut off into many droplets periodically by the other component which is injected from the other inlets. We considered the effect of the boundary conditions for density difference (order parameter) on the wetting of the droplet to the side walls.

  • PDF