• Title/Summary/Keyword: inlet concentration

Search Result 480, Processing Time 0.025 seconds

High Concentration Ozone Generation Characteristics by Variation of Additional Gases and Flow Rates of Inlet Gas (입력가스의 유량변화와 첨가가스에 따른 고농도 오존발생특성)

  • 박승록;이대희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2002
  • There are many effective parameters to high concentration ozone generation. These parameters became very important elements should be considered before designing ozone generator. After designing, there are many peripheral parameters to greatly affect to high concentration ozone generation also. In this study, of many effective peripheral parameters on high concentration ozone generation, the effects of flow rate of inlet oxygen gas and some kinds of additional gases on ozone concentration were investigated As a result, when inlet oxygen gas was introduced at the range of 0.75[LPM]~2.00[LPM] the highest ozone concentration of 71145[ppm] was obtained at 1.25[LPM]. When the additional nitrogen gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest ozone concentration of 73135[ppm] was obtained at 0.8[vol%] of nitrogen gas. This showed 3[%] increasing compared to the case of pure oxygen gas inlet. When the additional argon gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest concentration of 67288[ppm]was obtained at 0.8[vol%]of argon gas. This is decreased value compared to that of introducing the pure oxygen.

Analysis of Reactivity of Zn-Based Desulfurization Sorbents for Reducing Power, Water Vapor Content and H2S Content of the Coal Gas in a Batch-Type Fluidized-Bed Reactor (회분식 유동층반응기에서 세 종류 아연계 탈황제의 석탄가스 환원도, 수분함량, 황화수소함량에 따른 반응성 평가)

  • Park, Young Cheol;Jo, Sung-Ho;Son, Jae-Ek;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.710-714
    • /
    • 2009
  • In this study, we analyzed the desulfurization performance of Zn-based dry sorbents according to the reducing power, water vapor content and $H_2S$ inlet concentration of coal gas in a batch-type fluidized-bed reactor. We used three different coal gas composition with different reducing power such as KRW air-blown coal gas, Shell oxygenblown coal gas and IAE coal gas. The experiments were performed by changing the inlet concentration of water vapor and $H_2S$ in a coal gas. Water vapor content was varied from 5% to 30% and $H_2S$ inlet concentration from 0.5% to 2.0%. As both the water vapor content and $H_2S$ inlet concentration increased, desulfurization performance of Zn-based sorbents decreased regardless of the reducing power of the coal gas. The minimum desuflurization performance was, however, above 99.5% for all experimental conditions, which implied that Zn-based dry sorbents could be used to remove $H_2S$ up to 99%.

저온기 육용계사의 적정 환기체계 구명

  • 이덕수;나재천;최희철;송준익;이상진;김형호
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2002.11a
    • /
    • pp.108-109
    • /
    • 2002
  • The study was carried out to iind out the suitable ventilation system of the broiler house in winter season in Korea. Ammonia (NH$_3$-N) gas concentration (4.2ppm) of the system of pipe air inlet-forced chimney outlet was lower than that of the system of side wall inlet. The growth performance of broilers in the house equiped with pipe air inlet-chimney exhaust was higher than that of other ventilation systmes in which the average daily gain, feed efficiency and heat cost per head in the system of pipe air inlet-forced chimney excretion were 45.6g, 1.71 and 35.4 won per head, respectively. When the lengths of pipe air inlets were compared, the wind speed from the 4 meter-inlet was highest. The temperature of the broiler house equipped with the pipe air inlet system was higher (5.9 ∼ 7.7$^{\circ}C$) than that of the curtains in side wall Inlet system, in which the pipe air inlet system expects the lower heat cost.

  • PDF

Theoretical Analysis on the Synthesis of Ultrafine TiO2 Particles by Combustion Reaction (연소반응을 이용한 TiO2 초미립자 제조 공정에 대한 이론적 연구)

  • Chae, Bum-San;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.241-247
    • /
    • 1997
  • A numerical model has been proposed for a diffusion flame reactor to manufacture ultrafine $TiO_2$ powders. The model equations such as mass balance equation, the 0th, 1st, and 2nd moment equations of aerosols were considered. The phenomena such as $TiCl_4$ reaction rate, $TiO_2$ nucleation rate and the coagulation of $TiO_2$ powders were included in the aerosol dynamic equation. It is found that the $TiO_2$ particle concentration becomes higher, as the inlet $TiCl_4$ concentration and the total gas flow rate increase, and also as the flame temperature decreases. The $TiO_2$ particle size increases, as the flame temperature and the inlet $TiCl_4$ concentration increase and the total gas flow rate decreases.

  • PDF

Removal Characteristics of Toluene by the Combined Plasma/Photocatalyst System (플라즈마/광촉매 결합시스템에 의한 톨루엔 제거특성)

  • Yoa, S.J.;Heo, Y.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.64-71
    • /
    • 2007
  • The main purpose of this study is to analyze the characteristics of toluene removal by plasma, photocatalyst, and plasma/photocatalyst system with the major parameters such as flow rate, inlet toluene concentration and applied voltage, etc., experimentally. In the combined plasma/photocatalyst process, rates of toluene conversion are represented as 99% at flow rate 250, 500 mL/min while, below 97% at flow rate 1000 mL/min due to the low residence time(reaction time) at the same applied voltage 4173 voltage and toluene inlet concentration 50 ppm. The intermediate products are detected by GC/MS analysis showing the small amounts of benzoic acid, benzyl alcohol and residual ozone concentration $0.04{\sim}0.05$ ppm generated by plasma process in the present system.

  • PDF

A study on the ceramic filter trap in CI engine (CI기관에 있어서 세라믹 필터트랩에 관한 연구)

  • 한영출;유정호
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.54-60
    • /
    • 1988
  • This study is a theoretical analysis and experimental effect of oxygen concentration, exhaust velocity and trap inlet temperature on particulate ignition temperature with installation of ceramic filter trap in diesel engine. So the following results are obtained. 1, Based on the fundamental experiments of the regeneration process, the analytical model was developed and the results from the analytical model agreed with the experiments, then the validity of the model was proved. 2, The ignition temperature for accumulated particulate was proportional to the exhaust velocity and it was known that the optimum exhaust velocity was about 15m/sec. 3, The ignition temperature for accumulated particulate was inversely proportional to the oxygen concentration and the trap inlet temperature, and a minimum oxygen concentration of 5% was required to sustain regeneration. 4, This experimental filter trap(EX-66) is found about 30% of smoke reduction efficiency in comparison with existing muffler.

  • PDF

Removal of Hydrogen Sulfide Using Porous Ceramic Biofilter Inoculated with Sulfur Oxidizing Bacteria (황산화 균주가 부착된 다공성 세라믹 biofilter를 이용한 $H_2S$ 제거)

  • 박상진;조경숙
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.649-655
    • /
    • 1999
  • Biofiltration of polluted gas streams contained $H_2S$ was studied. The experiments were performed in a laboratory-scale reactor with a porous ceramic media inoculated with sulfur oxidizing bacterium, TAS which was isolated from activiated sludge. The concentration of $H_2S$ in the inlet gas varied from 109 to 3,841 ppm, at the various space velocities(SV) of 50 $h^{-1}$ to 250 $h^{-1}$. Various tests have been conducted to evaluate the effects of such parameters as pH, concentration of sulfate ion and retention time on the pressure drop and maximum elimination capacity. The removal efficiency of $H_2S$ decreased as the $H_2S$ concentration or gas velocity increased in the inlet gas. Pressure drop was insignificant in this system. The maximum elimination capacity could reach up to 16.35g-S/kg-dry packing material/day.

  • PDF

A Study on Ventilation Effectiveness Characteristics in a Apartment Housing (공동주택에서 환기효율 특성에 관한 수치적 연구)

  • Cha, Kwang-Suk;Lee, Dae-Woo;Yeom, Dong-Suk;Park, Myung-Sig
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.39-44
    • /
    • 2005
  • Recently according to the fashion of well-being, it is increasing that heat recovery ventilator is applied to the apartment housing, But the uniform locations of inlet and outlet in each room may provide better indoor air quality than ununiform locations of inlet and outlet. Proper design of air supply system requires information concerning the gas concentration difference between the ventilation effectiveness at the breathing line. This paper presents models to predict the gas concentration difference and the ventilation effectiveness, based on the two cases with proper number of outlets. As one of the results it is desirable to set the outlet location near the furniture which produce the contamination gas so much.

  • PDF

Numerical Analysis of Flow Uniformity in Selective Catalytic Reduction (SCR) Process Using Computational Fluid Dynamics (CFD)

  • Shon, Byung-Hyun
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.295-306
    • /
    • 2022
  • The NOx removal performance of the SCR process depends on various factors such as catalytic factors (catalyst composition, shape, space velocity, etc.), temperature and flow rate distribution of the exhaust gas. Among them, the uniformity of the flow flowing into the catalyst bed plays the most important role. In this study, the flow characteristics in the SCR reactor in the design stage were simulated using a three-dimensional numerical analysis technique to confirm the uniformity of the airflow. Due to the limitation of the installation space, the shape of the inlet duct was compared with the two types of inlet duct shape because there were many curved sections of the inlet duct and the duct size margin was not large. The effect of inlet duct shape, guide vane or mixer installation, and venturi shape change on SCR reactor internal flow, airflow uniformity, and space utilization rate of ammonia concentration were studied. It was found that the uniformity of the airflow reaching the catalyst layer was greatly improved when an inlet duct with a shape that could suppress drift was applied and guide vanes were installed in the curved part of the inlet duct to properly distribute the process gas. In addition, the space utilization rate was greatly improved when the duct at the rear of the nozzle was applied as a venturi type rather than a mixer for uniform distribution of ammonia gas.

Numerical Study on the Application of High Temperature Catalytic Combustion to a Gas Turbine (고온촉매연소의 가스터빈 적용에 관한 수치적 연구)

  • Kim, Hyung-Man;Jeun, Ho-Sig;Jang, Seok-Yong
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.989-994
    • /
    • 2001
  • Numerical simulations of high temperature catalytic combustion have been performed for the application to a gas turbine combustor. Dependences of inlet temperature and pressure on the distributions of temperature and species concentrations were investigated using plug flow model with detailed homogeneous and heterogeneous chemistries of methane-air mixtures. Honeycomb typecombustor deposited with Pt catalyst of 100mm in length and 26mm in diameter is used. The results show that rapid increase of temperature profile occurs earlier with the increase of inlet temperature and the decrease of inlet pressure. The condition which catalytic combustion is stabilized exists at certain range of inlet temperature and pressure. The state of catalytic combustion is also confirmed by the distributions of species concentration.

  • PDF