• Title/Summary/Keyword: inlet and outlet pipe

Search Result 90, Processing Time 0.024 seconds

Effect analysis of ISLOCA pathways on fission product release at Westinghouse 2-loop PWR using MELCOR

  • Kim, Seungwoo;Park, Yerim;Jin, Youngho;Kim, Dong Ha;Jae, Moosung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2878-2887
    • /
    • 2021
  • As the amount of fission product released from ISLOCA was overestimated because of conservative assumptions in the past, several studies have been recently conducted to evaluate the actual release amount. Among several pathways for the ISLOCA, most studies were focused on the pathway with the highest possibility. However, different ISLOCA pathways may have different fission product release characteristics. In this study, fission product behavior was analyzed for various pathways at the Westinghouse two-loop plant using MELCOR. Four pathways are considered: the pipes from a cold leg, from a downcomer, from a hot leg to the outlet of RHR heat exchanger, and the pipe from the hot leg to the inlet of RHR pump (Pathway 1-4). According to the analysis results, cladding fails at around 2.5 h in Pathways 1 and 2, and on the other hand, about 3.3 h in Pathways 3 and 4 because the ISLOCA pathways affect the safety injection flow path. While the release amount of cesium and iodine ranges between 20 and 26% in Pathways 1 to 3, Pathway 4 allows only 5% to the environment because the break location is submerged. Also, as more than 90% of cesium released to the environment passes through the personnel door, reinforcing the pressure capacity of the doors would be a significant factor in the accident management of the ISLOCA.

THERMAL HYDRAULIC ISSUES OF CONTAINMENT FILTERED VENTING SYSTEM FOR A LONG OPERATING TIME

  • Na, Young Su;Ha, Kwang Soon;Park, Rae-Joon;Park, Jong-Hwa;Cho, Song-Won
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.797-802
    • /
    • 2014
  • This study investigated the thermal hydraulic issues in the Containment Filtered Venting System (CFVS) for a long operating time using the MELCOR computer code. The modeling of the CFVS, including the models for pool scrubbing and the filter, was added to the input file for the OPR-1000, and a Station Blackout (SBO) was chosen as an accident scenario. Although depressurization in the containment building as a primary objective of the CFVS was successful, the decontamination feature by scrubbing and filtering in the CFVS for a long operating time could fail by the continuous evaporation of the scrubbing solution. After the operation of the CFVS, the atmosphere temperature in the CFVS became slightly above the water saturation temperature owing to the release of an amount of steam with high temperature from the containment building to the scrubbing solution. Reduced pipe diameters at the inlet and outlet of the CFVS vessel mitigated the evaporation of scrubbing water by controlling the amount of high-temperature steam and the water saturation temperature.

Flow Network Analysis for the Flow Control of a Main Cooling Water System in the HANARO Fuel Test Loop (하나로 핵연료 시험 루프 주냉각수 계통의 유량 제어에 대한 유동 해석)

  • Park, Young-Chul;Lee, Yong-Sub;Chi, Dae-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.7-12
    • /
    • 2009
  • A nuclear fuel test loop(after below, FTL) is installed in the IRI of an irradiation hole in HANARO for testing the neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. There is an in-pile section(IPS) and an out-pile section(OPS) in this test loop. When HANARO is operated normally, the fuel loaded into the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain the operation conditions of the test fuel, a main cooling water system(MCWS) is installed in the OPS of the FTL. The MCWS is composed of a main cooler, a pressurizer, two circulation pumps, a main heater, an interconnection pipe line and instruments. The interconnection pipeline is a closed loop which is connected to an inlet and an outlet of the IPS respectively. The MCWS is under a cold function test during a start-up period. This paper describes the system flow network analysis results of the flow control of a main cooling water system in the HANARO fuel test loop. It was confirmed through the results that the flow was met the system design requirements.

A Parametric Study for the Design of Gas-Liquid Centrifugal Separator (기체-액체 원심분리기의 설계를 위한 매개변수 연구)

  • Nagdewe, Suryakant;Lee, S.J.;Kim, H.D.;Kim, D.S.;Kwak, K.M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.218-219
    • /
    • 2008
  • A gas-liquid centrifugal separator is widely used in industry because of its simple geometry and little maintenance. Also, these separators have considerable advantages over filters, scrubbers or precipitators in term of compact design, low pressure drop and higher capacity. A gas-liquid centrifugal separator is a device that utilizes centrifugal force and low pressure to separate liquid from gas by density difference. Design parameters such as length of separation space, swirl vane exit angle, inlet to outlet pipe diameter ratio, models for separation efficiency and low pressure drop as a function of physical dimension are not available in literature. In present study, length of separation space (from vane to gas exit opening) has been studied using CFD. The 3-D Navier-Stokes equations are numerically solved using a fully implicit finite volume scheme. Based upon the obtained solutions, tangential velocities, centrifugal forces, vortices and total pressure losses are analyzed to find the best design parameters.

  • PDF

Underground Heat Transfer Characteristics of the Underground Heating System for Soil Sterilization in Greenhouse (온실 내 토양소독을 위한 지중난방시스템의 지중 열전달 특성)

  • Park, Kyung-Kyoo;Ha, Yu-Shin;Hong, Dong-Hyuck;Jang, Seung-Ho;Kim, Jin-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.35 no.2
    • /
    • pp.108-115
    • /
    • 2010
  • This study was conducted to estimate the optimum temperature and required time for soil sterilization when heated water was circulated through underground heating pipes in the greenhouse which solar heat was influenced to the temperature of soil during the summer day. Two different types of heating pipes were used for the experiment. One was a polyethylene pipe(XL) and the other was a corrugated ring shaped stainless steel pipe(STS). The results of the studies were summarized as follows; By measuring the thermal characteristics of the XL and STS, it was examined that the average temperature differences of the inlet and outlet were $8.5^{\circ}C$ and $13.3^{\circ}C$, the average flowrates were 15.3 L/min and 5.6 L/min, and the average radiation powers were 9.1 kW and 4.1 kW, respectively. As results of the regression analysis of underground temperatures, when average soil temperature was$35^{\circ}C$, an average water temperature was $80^{\circ}C$, and XL was used, it was estimated that the possible heat transfer distance, the required time for heat transfer and heat flux to reach the underground temperature of $60^{\circ}C$ were 300 mm, 230 hours, and $7.57kW/m^2$, respectively.

Effect of the Presence of Sub-pipes on the Performance of Water Nozzle (서브파이프의 유무에 따른 워터노즐의 성능특성연구)

  • Yi, Young-Woo;Lim, Hee-Chang
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.17-24
    • /
    • 2018
  • This paper presents a numerical analysis of flow inside a water nozzle for fire fighting and observes the effect of the variation in primary components on internal flow. In order to observe the performance of water nozzles, they have been systematically designed and modelled, applying boundary conditions obtained from field experiments (inlet pressure at pump : 4 bar, and pressure outlet : atmospheric pressure). In addition, the governing equations were calculated to obtain velocity, pressure inside the nozzle. Two main parameters (the presence and length of sub-pipes) were considered with the aim to observe the detail internal flow characteristics. It is found that the base model is not significant on flow characteristics, but a negative effect (i. e. the reverse flow) at the entrance region of sub-pipe. On the other hand, the reverse flow was vanished when making the length of sub-pipe double.

An Analysis of the Impact of Design Factors Using a Simulator of LH2 Storage Tank PRV System (시뮬레이터를 이용한 LH2 저장탱크 PRV시스템의 설계요소 영향분석)

  • Chungkeun Chae;Gyeongtae Im;Yonggyu Kim;Seungbeen Chae
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.47-55
    • /
    • 2024
  • More than 100 liquefied hydrogen tanks are expected to be introduced in Korea by 2030. Since liquefied hydrogen is stored in a vacuum insulation structure tank at -253℃, there is a possibility of a major disaster in which the tank bursts if there is a problem with insulation. Therefore, the law stipulates that PRV should be installed as the last bastion. It is important to note that in the case of liquefied hydrogen, it becomes useless if the pressure drop of the pipe is ignored and the capacity is calculated incorrectly. In CGA S-1.3, the pressure drop rate of the PRV inlet and outlet pipes is set to less than 3% and less than 10%, respectively. However, there is an interdependence between the amount of pressure drop and the flow rate of the pipe, making it impossible to calculate these values at once. Therefore, we developed a simulator that calculates the pressure loss rate of PRV system using MATLAB/Simulink and evaluated the sensitivity of the pressure drop rate to design elements.

Comparison of Flow Characteristics for the Development of a C-Type Strainer with Its Inlet and Outlet on a Straight Line (유입·유출구가 일직선상인 C형 스트레이너 개발을 위한 유동특성 비교)

  • Shin, Byung-kyun;Kwon, Chang-Hee
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.257-265
    • /
    • 2016
  • The purpose of this study was to develop a strainer that could protect a flow system by blocking the introduction of foreign substances into the pipe of industrial or architectural facilities. Strainers are installed at the front tip of valves, machines, or pumps in the piping line of clean water, oil, or gas. There are Y-type, U-type, and T-type strainers. The study identified problems with the Y-type strainers, develop a "C-type strainer with its inlet and outlet on a straight line" as a more improved new model, and compared them in functions in a full-scale strainer test. The study conducted a full-scale strainer test according to four situations at the flow laboratory of Korea Research Institute of Standards and Science by using the old Y-type strainer and C-type strainer 50A. The test results show that the C-type strainer had a higher capacity coefficient(Kv) than the Y-type one, recording 74.9% when there was no screen, 54.5% when there were no foreign substances in the screen, 54.2% when there was a 15% accumulation of foreign substances, and 52.4% when there was a 30% accumulation of foreign substances. The investigator conducted a test only with the 50A type due to the limitations of life-size strainers, but the results demonstrate that the C-type strainer had better flow characteristics than the Y-type one.

Experimental and model study on the mixing effect of injection method in UV/H2O2 process

  • Heekyong Oh;Pyonghwa Jang;Jinseok Hyung;Jayong Koo;SungKyu Maeng
    • Membrane and Water Treatment
    • /
    • v.14 no.3
    • /
    • pp.129-140
    • /
    • 2023
  • The appropriate injection of H2O2 is essential to produce hydroxyl radicals (OH·) by mixing H2O2 quickly and exposing the resulting H2O2 solution to UV irradiation. This study focused on evaluating mixing device of H2O2 as a design factor of UV/H2O2 AOP pilot plant using a surface water. The experimental investigation involved both experimental and model-based analyses to evaluate the mixing effect of different devices available for the H2O2 injection of a tubular hollow pipe, elliptical type of inline mixer, and nozzle-type injection mixer. Computational fluid dynamics analysis was employed to model and simulate the mixing devices. The results showed that the elliptical type of inline mixer showed the highest uniformity of 95%, followed by the nozzle mixer with 83%, and the hollow pipe with only 18%, after passing through each mixing device. These results indicated that the elliptical type of inline mixer was the most effective in mixing H2O2 in a bulk. Regarding the pressure drops between the inlet and outlet of pipe, the elliptical-type inline mixer exhibited the highest pressure drop of 15.8 kPa, which was unfavorable for operation. On the other hand, the nozzle mixer and hollow pipe showed similar pressure drops of 0.4 kPa and 0.3 kPa, respectively. Experimental study showed that the elliptical type of inline and nozzle-type injection mixers worked well for low concentration (less than 5mg/L) of H2O2 injection within 10% of the input value, indicating that both mixers were appropriate for required H2O2 concentration and mixing intensity of UV/ H2O2 AOP process. Additionally, the elliptical-type inline mixer proved to be more stable than the nozzle-type injection mixer when dealing with highly concentrated pollutants entering the UV/H2O2 AOP process. It is recommended to use a suitable mixing device to meet the desired range of H2O2 concentration in AOP process.

Cavitation Analysis on Ship Seawater Pump Using CFD (CFD를 이용한 선박용 해수펌프의 공동현상에 대한 분석)

  • Kim, Bu-Gi;Kim, Hong-Ryeol;Yang, Chang-Jo;Kim, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.4
    • /
    • pp.400-406
    • /
    • 2017
  • The model used in this study was reversed to analyze the cause of excessive damage that occurred inside the rotating system and pipe system of a centrifugal-type seawater pump on a ship. For this purpose, internal flow analysis on a cooling seawater pump was performed using CFD. As a result, the shape and boundary conditions of the target pump were set by reverse engineering, and pump efficiency at a design operating point of $125m^3/h$ was calculated as 85.3 % with a head of 32.0 m. The maximum efficiency point of the target pump was estimated to be 86.2 % at $150m^3/h$, but this differed from the actual operating point. At $112.5m^3/h$, which was the lowest flow point, flow was unstable due to the characteristics of the low flow point and analysis convergence was not good. The purpose of this study was to clarify the cause of ongoing cavitation in seawater pumps and piping systems in operation. Future research will be needed to clarify causes for pipe systems in the future by performing calculations for the total piping system of an inlet and outlet, in addition to measuring the flow rate of each branch pipe.