DOI QR코드

DOI QR Code

Flow Network Analysis for the Flow Control of a Main Cooling Water System in the HANARO Fuel Test Loop

하나로 핵연료 시험 루프 주냉각수 계통의 유량 제어에 대한 유동 해석

  • Published : 2009.10.01

Abstract

A nuclear fuel test loop(after below, FTL) is installed in the IRI of an irradiation hole in HANARO for testing the neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. There is an in-pile section(IPS) and an out-pile section(OPS) in this test loop. When HANARO is operated normally, the fuel loaded into the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain the operation conditions of the test fuel, a main cooling water system(MCWS) is installed in the OPS of the FTL. The MCWS is composed of a main cooler, a pressurizer, two circulation pumps, a main heater, an interconnection pipe line and instruments. The interconnection pipeline is a closed loop which is connected to an inlet and an outlet of the IPS respectively. The MCWS is under a cold function test during a start-up period. This paper describes the system flow network analysis results of the flow control of a main cooling water system in the HANARO fuel test loop. It was confirmed through the results that the flow was met the system design requirements.

Keywords

References

  1. Y. C. Park, et a1. 1996, 'System Perlormance Test in HANARO,' the 5th ASRR Vol. 1, pp. 240-246
  2. KAERI, 2006, 'Safety Analysis Report of Fuel Test Loop'
  3. HEC,2005,'Design Manual of Mechanical,' HAN-FL-ED70-DM-H001,Operation condition
  4. Flow Network Analysis, 5.0C, 'User’s Manual,' Kelix SoFtware Co. 1985
  5. Hooper, W. B. 1981, 'The Two-K Method Predicts Head Losses in Pipe Fittings,' Chem. Engr. Aug. 24. pp. 97-100
  6. Merie C. Potter and Elaine P. Scott, 'An lntroduction to Fluid Mechanics,' Thomson