A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS (PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.121-127
    • /
    • 2016
  • This study analyzed the structural and electrical characteristics of an iron fittings type Corrugated Stainless Steel Tubing (CSST) damaged by the Primary Current Injection Test System (PCITS). CSST consists of cladding, tube, nuts, clamp ring, flare cap, socket, and ball valve. For an evaluation of the dielectric withstand voltage, the area between the live part and non-live part of the CCST shall withstand a voltage of 220 V AC for one minute. For an evaluation of the insulation performance by 500 V DC, it is required that the insulation exceed more than $1M{\Omega}$ before the temperature rise test, $0.3M{\Omega}$ after the test. Although the average resistance of the product was $11.5m{\Omega}$, that of the product damaged at a current of 130 A by the PCITS was $11.50m{\Omega}$. Furthermore, parts of the cladding were melted and black smoke appeared when a current of 130 A applied for 10 s. After 60 s, most parts were heated and turned red. At 120 s, the parts that turned red had widened. Although it did not form a normal distribution because the P value was 0.019 with a confidential interval of 95%, it revealed outstanding characteristics with an AD (Anderson-Darling) value of 0.896 and a standard deviation of 0.5573.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

The Role of Protein Kinase C in Acute Lung Injury Induced by Endotoxin (내독소에 의한 급성폐손상에서 Protein Kinase C의 역할)

  • Kim, Yong-Hoon;Moon, Seung-Hyug;Kee, Sin-Young;Ju, Jae-Hak;Park, Tae-Eung;Im, Keon-Il;Cheong, Seung-Whan;Kim, Hyeon-Tae;Park, Choon-Sik;Jin, Byung-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.349-359
    • /
    • 1997
  • Background : The signal pathways and their precise roles for acute respiratory distress syndrome caused by endotoxin (ETX) has not been established. Since there has been several in vitro experiments suggesting that activation of protein kinase C (PKC) pathway may be responsible for endotoxin-induced inflammatory reaction, we performed in vivo experiments in the rats with the hypothesis that PKC-inhibition can effectively prevent endotoxin-induced acute lung injury. Methods : We studied the role of PKC in ETX-induced ALI using PKC inhibitor (staurosporine, STP) in the rat Specific pathogen free male Sprague-Dawley weighted from 165 to 270g were used for the study. Animals were divided into the normal control (NC)-, vehicle control (VC)-, ETX-, PMA (phorbolmyristateacetate)-, STP+PMA-, and STP+ETX-group. PMA (50mg/kg) or ETX (7mg/kg) was instilled through polyethylen catheter after aseptic tracheostomy with and without STP (0.2mg/kg)-pretreatment STP was injected via tail vein 30min before intratracheal injection (IT) of PMA or ETX. Bronchoalveolar lavage (BAL) was done 3-or 6-hrs after IT of PMA or ETX respectively, to measure protein concentration, total and differential cell counts. Results : The results were as follows. The protein concentrations in BALF in the PMA- and ETX-group were very higher than that of VC-group (p<0.001). When animals were pretreated with STP, the %reduction of the protein concentration in BALF was $64.8{\pm}8.5$ and $30.4{\pm}2.5%$ in the STP+PMA- and STP+ETX-group, respectively (p = 0.028). There was no difference in the total cell counts between the PMA-and VC-group (p = 0.26). However the ETX-group showed markedly increased total cell counts as compared to the VC- (p = 0.003) and PMA-group (p = 0.0027), respectively. The total cell counts in BALF were not changed after pretreatment with STP compared to the PMA- (p = 0.22) and ETX-group (p = 0.46). The percentage of PMN, but not alveolar macrophage, was significantly elevated in the PMA-, and ETX-group. Especially in the ETX-group, the percentage of PMN was 17 times higher than that of PMA (p < 0.001). The differential cell counts was not different between the PMA and STP+PMA On the contrary the STP+ETX-group showed decreased percentage of PMN (p = 0.016). There was no significant relationship between the protein concentration and the total or differential cell counts in each group. Conclusion : Pretreatment with PKC-inhibitor (staurosporine) partially but significantly inhibited ETX-induced ALI.

  • PDF