• 제목/요약/키워드: injection detection

검색결과 486건 처리시간 0.026초

A successful pregnancy using completely immotile but viable frozen-thawed spermatozoa selected by laser

  • Chen, Huanhua;Feng, Guixue;Zhang, Bo;Zhou, Hong;Shu, Jinhui;Gan, Xianyou
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제44권1호
    • /
    • pp.52-55
    • /
    • 2017
  • The aim of this study was to report a successful pregnancy using completely immotile frozen-thawed spermatozoa selected by laser. A single laser shot was used to detect the presence of viable immotile spermatozoa in fresh and frozen-thawed testicular spermatozoa. The viability rate was 55.8% after the laser detection, and cryopreservation was carried out immediately. The thawing test was performed on the day of oocyte pick-up, and no motile sperm were observed after extending the culture for another 4 hours, while a survival rate of 39.8% was detected using the laser. In all, five mature oocytes were injected, resulting in four cases of normal fertilization (80%) on day 1. Further, two high-quality day 3 embryos were transferred, which resulted in a singleton pregnancy. Our study demonstrates that completely immotile spermatozoa are worth cryopreserving for further intracytoplasmic sperm injection, which provides a new insight into male fertility preservation in cases of completely immotile spermatozoa.

DNA Concentration Effect of Various Hydroxide Compounds on Stacking in Capillary Electrophoresis

  • Shin, Ah-Ram;Kang, Seong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권12호
    • /
    • pp.4316-4320
    • /
    • 2011
  • The effects of various hydroxide compounds on base stacking (BS) were investigated for pre-concentration of DNA molecules in capillary electrophoresis (CE). In BS, hydroxide ions ($OH^-$) were electrokinetically introduced after DNA sample injection. A neutralization reaction occurred between the $OH^-$ and $Tris^+$ of the running buffer, which resulted in a zone of lower conductivity. Within the low conductivity zone of the high electric field, the DNA molecules moved more rapidly and were concentrated in front of the low conductivity zone. At the same BS conditions of CE, the enhanced sensitivity of the DNA samples was dependent on the kind of multivalent cations in the hydroxide compounds. Except for LiOH, the hydroxide compounds with monovalent cations showed more effective BS than those with divalent cations because of solubility, ionic strength and electronegativity. The order of hydroxide compounds that enhance the detection sensitivity of DNA molecules was as follows: NaOH > $NH_4OH$ > KOH > $Ba(OH)_2$ > $Sr(OH)_2$ > LiOH > $Ca(OH)_2$ > $Mg(OH)_2$. $NH_4OH$, KOH and $Ba(OH)_2$ proved to be efficient hydroxide compounds to use as effective BS reagents in CE instead of NaOH.

Detection of Magnetic Nanoparticles in Tissue Using Magneto-Motive DP-OCT

  • Oh, Jung-Hwan;Lee, Ho;Kim, Jee-Hyun
    • Journal of the Optical Society of Korea
    • /
    • 제11권1호
    • /
    • pp.26-33
    • /
    • 2007
  • We demonstrate the capability of differential-phase optical coherence tomography (DP-OCT) to detect superparamagnetic iron oxide (SPIO) nanoparticles taken up by liver parenchymeal macrophages (Kupffer cells). We apply an external time-varying high-intensity focused magnetic field. Our experiments demonstrate a novel diagnostic modality to detect macrophages that have taken up SPIO nanoparticles. Magnetic force acting on the nanoparticles was varied by applying a sinusoidal current to a solenoid containing a conical iron core that substantially increased and focused the magnetic field strength ($B_{max}$ = 2 Tesla). $ApoE^{-/-}$ mice were sacrificed 2 days post intravenous injections of different SPIO doses (1.0, and 0.1 mmol Fe/kg body weight). Livers of $ApoE^{-/-}$ mice with and without injection of SPIO nanoparticles were investigated using DP-OCT, which detects tissue movement with nanometer resolution. Frequency response of iron-laden liver movement was twice the stimulus frequency. Movement was not observed in livers of control mice. Results of our experiments indicate DP-OCT is a candidate methodology to detect tissue based macrophages containing SPIO nanoparticles excited by an external focused magnetic field.

일회용 스트립형 효소면역센서용 플랫폼의 개발 (Development of Disposable Enzyme-linked Immunosensor Strip Platform)

  • 최지혜;이승재;장승철;김경천
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.400-405
    • /
    • 2011
  • This study introduced the development of a strip type disposable enzyme-linked immunosensor platform for the detection of IgG. Strips of the strip sensor were fabricated by using commercial nitrocellulose filter membranes and a housing holder for the strips was manufactured by using a standard injection molding process for a plastic material. An IgG-urease conjugate was prepared and used for the competitive immune-binding with sample IgG. From the enzymatic reaction between the conjugated urease and urea added, ammonia was generated and caused a localized alkaline pH change on the immobilized antibody band which was coated onto the sensor strips. This pH increase subsequently caused a color change of the antibody band in the presence of a pH indicator, phenol red. Used in conjunction with a competitive immunoassay format, the intensity of the color produced is directly linked with the concentration of target analyte, IgG, and specific measurement of IgG in a lateral flow immunoassay format was achieved over the range 100 ppb to 2000 ppb IgG.

추적자시험에 의한 폐기물매립장 침출수 누출조사 (Investigation of Leachate Leakage in Waste Landfill by Tracer Test)

  • 이광열;이영준;장삼식
    • 한국지반공학회논문집
    • /
    • 제20권4호
    • /
    • pp.49-56
    • /
    • 2004
  • 본 연구에서는 추적자시험을 이용하여 매립종료된 폐기물매립장에서 꿰뚫림하중에 의해 파손된 차수재를 통한 침출수의 누출 여부를 조사하였다. 추적자시험은 자연구배형식을 채택하였으며, 추적자로는 iodide and Rhodamine WT를 사용하였다. 이 두 추적자는 침출수의 화학적 성분과 반응성을 충분히 고려하여 선정하였다 시험에서는 매립장 전체를 통하여 5개의 주입정과 14개의 관측공을 설치하여 운영하였다. 본 연구의 결과에 의하면, Iodide and Rhodamine WT 추적자는 매립장 침출수 누출조사에 적용 가능하며 효과적임을 확인하였으며, 다량의 침출수가 우수 관로와 우수관로의 외측 벽면을 통하여 누출되었던 것으로 추정된다.

120kV/70A MOSFETs Switch의 구동회로 개발 (Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit)

  • 송인호;신현석;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.707-710
    • /
    • 2002
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute in Taejon to supply power with Korea Superconducting Tokamak Advanced Research (KSTAR) Neutral Beam Injection (NBI) system. NBI system requires fast cutoff of the power supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply and there are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply, Various results taken during the commissioning phase with a 100kW resistive load and NBI source are shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver and solutions are also presented.

  • PDF

Quantitative Analysis of Twelve Marker Compounds in Palmijihwang-hwan using Ultra-Performance Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • 제20권3호
    • /
    • pp.182-190
    • /
    • 2014
  • An ultra-performance liquid chromatography (UPLC) coupled with electrospray ionization (ESI) tandem mass spectrometry (MS) method was established for quantitative analysis of twelve components, allantoin (1), morroniside (2), 5-hydroxymethyl-2-furfural (5-HMF) (3), loganin (4), coumarin (5), cinnamic acid (6), mesaconitine (7), cinnamaldehyde (8), hypaconitine (9), aconitine (10), alisol B (11), and alisol B acetate (12) in a Palmijihwang-hwan decoction. The twelve constituents were separated on a UPLC BEH C18 column ($2.1{\times}100mm$, $1.7{\mu}m$) at a column temperature of $40^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as the mobile phase. The flow rate was 0.3 mL/min and the injection volume was $2.0{\mu}L$. Calibration curves of all compounds were acquired with values of the correlation coefficient ${\geq}0.99$ within the test ranges. The limits of detection and quantification for all analytes were 0.01 - 4.53 ng/mL and 0.03 - 13.60 ng/mL, respectively. The concentrations of the compounds 1 - 9 and 12 were 72.83, 4389.00, 4859.00, 3155.17, 223.67, 33.50, 1.97, 518.00, 2.25, and $25.00{\mu}g/g$, respectively. However, compounds 10 and 11 were not detected.

Content Analysis of Rutin in the Leaves of Boehmeria nivea Harvested in Different Regions of South Korea by HPLC-UV

  • Cho, Sunghun;Quilantang, Norman G.;Lee, Ju Sung;Kim, Young-Mi;Kim, Ho Bang;Cho, Eun Ju;Jung, Yong-Su;Lee, Sanghyun
    • Natural Product Sciences
    • /
    • 제24권1호
    • /
    • pp.36-39
    • /
    • 2018
  • Phytochemical analysis of Boehmeria nivea (Bn) leaves by medium pressure liquid chromatography led to the isolation of a flavonoid glycoside identified by spectroscopic analysis as rutin. The amount of rutin in the leaves of Bn harvested from nine regions in South Korea (Bn 1-9) which were collected on the months of June, July, August, and September was determined by HPLC-UV analysis. A gradient elution program that utilizes a $Discovery^{(R)}$ C18 ($4.6{\times}250mm$, $5{\mu}m$) column and mobile phase composed of 1% acetic acid-water: acetonitrile (90:10 to 60:40 for min) was followed. The injection volume and flow rate were $10{\mu}l$ and 1 mL/ min, respectively. UV detection was set at 350 nm. Results show that Bn-8 harvested in September reported the highest content of rutin among the samples analyzed. This study provides a basis for the optimal harvest time of Bn which maximizes the yield of rutin.

Quantitative Determination of Bakkenolide D in Petasites japonicus and Farfugium japonicum by HPLC/UV

  • Quilantang, Norman G.;Lee, Ki Ho;Lee, Dong Gu;Lee, Ju Sung;Cho, EunJu;Kim, Hyun Young;Lee, Sanghyun
    • Natural Product Sciences
    • /
    • 제23권4호
    • /
    • pp.270-273
    • /
    • 2017
  • A quantitative analysis of bakkenolide D in the different parts of Petasites japonicus and Farfugium japonicum was performed by HPLC. A gradient HPLC elution system with a mobile phase consisting of water: acetonitrile solution (20:80 to 0:100 for 45 min) was followed and an INNO $C_{18}$ column was used for the chromatographic separation. The injection volume, flow rate, and UV detection were $10{\mu}L$, 1 mL/min, and 290 nm, respectively. Results show that both species showed the highest amount of bakkenolide D in the roots being 107.203 and 166.103 mg/g for P. japonicas and F. japonicum, respectively. Content analysis on the different parts of both plants displayed remarkably lower values which ranged from 0.403 - 4.419 and 7.252 - 32.614 mg/g for P. japonicas and F. japonicum, respectively. The results show that the roots of both plants are rich in bakkenolide D showing a promising use in the development of nutraceuticals and industrial application of the compound.

LC-MS/MS를 이용한 향사육군자탕의 주요성분의 함량분석 (Quantitative Analysis of Hyangsayukgunja-Tang Using an Ultra-Performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry)

  • 서창섭;신현규
    • 생약학회지
    • /
    • 제46권4호
    • /
    • pp.352-364
    • /
    • 2015
  • The aim of this study was to quantitatively analyze for quality assessment of eighteen marker compounds, including homogentisic acid, 3,4-dihydroxybenzaldehyde, spinosin, liquiritin, hesperidin, ginsenoside Rg1, liquiritigenin, ginsenoside Rb1, glycyrrhizin, 6-gingerol, atractylenolide III, honokiol, costunolide, dehydrocostuslactone, atractylenolide II, nootkatone, magnolol, and atractylenolide I, in Hyangsayukgunja-tang using an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer. The column for separation of eighteen marker components were used a UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}$) and kept at $45^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as mobile phase. The flow rate and injection volume were 0.3 mL/min and $2.0{\mu}l$, respectively. The correlation coefficient of all marker compounds was ${\geq}0.9914$, which means good linearity, within the test ranges. The limits of detection and quantification values of the all analytes were in the ranges 0.04-1.11 and 0.13-3.33 ng/mL, respectively. As a result, five compounds, homogentisic acid, 3,4-dihydroxybenzaldehyde, spinosin, liquiritigenin, and atractylenolide I, in this sample were not detected and the amounts of the 13 compounds except for the 5 compounds were $8.10-6736.37{\mu}g/g$ in Hyangsayukgunja-tang extract.