• Title/Summary/Keyword: injection detection

Search Result 484, Processing Time 0.027 seconds

Improment of Diesel Combustion using multiple injection under Cold Start Condition (냉시동 조건에서 디젤 연소 특성 및 연소 개선에 대한 연구)

  • Lee, Haeng-Soo;Lee, Jin-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.711-717
    • /
    • 2017
  • Startability and harmful emissions are the main issues in diesel engine development under cold conditions. The characteristics of combustion with multiple injection were investigated under cold start conditions. For quantitative analysis, the in-chamber pressure profile was measured and combustion visualization using direct imaging was accomplished. With multiple injection, the peak in-chamber pressure and heat release rate were increased compared to single injection. In addition, the period of flame luminosity detection was shortened using multiple injection. Combustion by main injection was improved with an increase in heat released by pilot combustion when the pilot injection quantity was increased. Finally, an increase in injection pressure also showed the possibility of combustion improvement. On the other hand, an increase of in the pilot injection quantity and injection pressure can cause an increase in harmful emissions, such as HC and CO due to wall wetting. Therefore, more sensitive calibration will be needed when applying a multiple injection strategy under cold start conditions.

Pyrocatechol Violet Modified Graphite Pencil Electrode for Flow Injection Amperometric Determination of Sulfide

  • Emir, Gamze;Karakaya, Serkan;Dilgin, Yusuf
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.248-256
    • /
    • 2020
  • In this study, pyrocatechol violet (Pcv) is proposed for the first time as an efficient electrocatalyst for oxidation of sulfide and flow injection analysis (FIA) of sulfide. A graphite pencil electrode (GPE) was modified with Pcv via immersion of the GPE into 0.01 M Pcv solution for 15 min. Cyclic voltammograms (CVs) demonstrated that Pcv/GPE exhibits a good electrocatalytic performance due to shift in the potential from +400 at bare GPE to +70 mV at Pcv/GPE and obtaining an enhancement in the peak current compared with the bare GPE. A linear range between 0.25 and 250 μM sulfide with a detection limit of 0.07 μM was obtained from the recorded current-time curves in Flow Injection Analysis (FIA) of sulfide. Sulfide in water samples was also successfully determined using the proposed FI amperometric methods.

Analysis for Pole to Ground Fault Detection in Ungrounded LVDC Distribution Network (비접지 LVDC 배전망의 지락고장 검출을 위한 분석)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.119-124
    • /
    • 2018
  • Recently, LVDC distribution network and DC microgrid with many advantages are being built. However, this LVDC distribution is an IT grounded or ungrounded system, and it is difficult to detect a ground fault because the fault current is small. In this paper, we propose a signal injection method for unipolar LVDC distribution network to detect ground fault in ungrounded LVDC distribution, and various analyzes were performed for ground fault detection.

Microbead-based bio-assay using quantum dot fluorescence in a microfluidic chip (미소유체 칩 상에서 Quantum Dot 및 마이크로 비드를 이용한 생체물질 분석)

  • Yun, Kwang-Seok;Lee, Do-Hoon;Kim, Hak-Sung;Yoon, Eui-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.308-312
    • /
    • 2005
  • We present a microfluidic chip designed for the detection of antibody by using quantum dots fluorescence and a microbead-based assay. A custom designed PDMS microfluidic chip with multi-layer channel is utilized for capturing microbeads; antibody injection into each micro-well; QD injection; and fluorescence detection. The experiment using the fabricated microfluidic chip has been performed on solutions with various concentrations of antibody and has shown correlated fluorescent intensities.

Enhancing Method to make Cluster for Filtering-based Sensor Networks (여과기법 보안효율을 높이기 위한 센서네트워크 클러스터링 방법)

  • Kim, Byung-Hee;Cho, Tae-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.141-145
    • /
    • 2008
  • Wireless sensor network (WSN) is expected to be used in many applications. However, sensor nodes still have some secure problems to use them in the real applications. They are typically deployed on open, wide, and unattended environments. An adversary using these features can easily compromise the deployed sensor nodes and use compromised sensor nodes to inject fabricated data to the sensor network (false data injection attack). The injected fabricated data drains much energy of them and causes a false alarm. To detect and drop the injected fabricated data, a filtering-based security method and adaptive methods are proposed. The number of different partitions is important to make event report since they can make a correctness event report if the representative node does not receive message authentication codes made by the different partition keys. The proposed methods cannot guarantee the detection power since they do not consider the filtering scheme. We proposed clustering method for filtering-based secure methods. Our proposed method uses fuzzy system to enhance the detection power of a cluster.

  • PDF

Determination of Trace Anions in Concentrated Hydrogen Peroxide by Direct Injection Ion Chromatography with Conductivity Detection after Pt-Catalyzed On-Line Decomposition

  • 김도희;이보경;이동수
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.696-700
    • /
    • 1999
  • A method has been developed for the determination of trace anion impurities in concentrated hydrogen peroxide. The method involves on-line decomposition of hydrogen peroxide, ion chromatographic separation and subsequent suppressed-type conductivity detection. H2O2 is decomposed in Pt-catalyst filled Gore-Tex membrane tubing and the resulting aqueous solution containing analytes is introduced to the injection valve of an ion chromatograph for periodic determinations. The oxygen gas evolving within the membrane tubing escapes freely through the membrane wall causing no problem in ion chromatographic analysis. Decomposition efficiency is above 99.99% at a flow rate of 0.4mL/min for a 30% hydrogen peroxide concentration. Analytes are quantitatively retained. The analysis results for several brands of commercial hydrogen peroxides are reported.

An Inspection Method for Injection Molded Automotive Parts using Line-Scan (라인스캔을 이용한 자동차 사출성형 부품의 검사 기술)

  • Yun, Jae-Sik;Kim, Jin-Wook;Huh, Man-Tak;Kim, Seok-Tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.805-807
    • /
    • 2011
  • In this paper, we propose a method to inspect defects of injection molded automotive parts. In order to inspect them, we developed and used a line detection algorithm and a defect analysis algorithm. The line detection algorithm defines center point of a laser line and the inspection algorithm determines the defects of automotive parts using pattern data of inspected objects and the data results from the line detection algorithm. We evaluated the accuracy and the processing time of inspection and they showed good performance.

  • PDF

Single Crystalline CoFe/MgO Tunnel Contact on Nondegenerate Ge with a Proper Resistance-Area Product for Efficient Spin Injection and Detection

  • Jeon, Kun-Rok;Min, Byoung-Chul;Lee, Hun-Sung;Shin, Il-Jae;Park, Chang-Yup;Shin, Sung-Chul
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2010.06a
    • /
    • pp.96-96
    • /
    • 2010
  • We report the proper resistance-area products in the single crystalline bcc CoFe/MgO tunnel contact on nondegenerate n-Ge desirable for efficient spin injection and detection at room temperature. The electric properties of the crystalline CoFe(5 nm)/MgO(1.5,2.0,2.5 nm)/n-Ge(001) tunnel contacts have been investigated by I-V-T and C-V measurements. Interestingly, the tunnel contact with the 2-nm MgO exhibits the ohmic behavior with low resistance-area products, satisfying the theoretical conditions required for significant spin injection and detection. This result is ascribed to the presence of MgO layer between CoFe and n-Ge, enhancing the Schottky pinning parameter as well as shifting the charge neutrality level.

  • PDF

Photometric Determination of Chlorite ion by Flow Injection Analysis (흐름주입 분석에 의한 아염소산 이온의 분광광도법 정량)

  • Choi, Yong Wook;Lee, Su Young;Kim, Mi Kyung;Park, Sung Ho
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.556-562
    • /
    • 2000
  • The determination of chlorite ion by flow injection analysis(FIA) with iodometric UV detection were investigated. Under rather acidic condition, chlorite ion react with iodide ion to form iodine and itself is reduced to chloride ion. The chlorite ion was determined indirectly by measuring absorbance of yellow colored iodine at 370 nm. The lengths of the mixing coil and the reaction coil, the pH of the acid stream, the concentration of the iodide ion, the injection loop volume, temperature, and flowrate were optimized as parameters for selectively determining a sort of inorganic disinfection by-product, chlorite ion by using FIA-UV detection setup. Masking agents for removing oxidants or interferences from the prepared water were tested. Independent calibration curve presented linear range of 0.002-0.2 mg/L for chlorite ion with a correlation coefficient of 0.999 or better. The limit of detection(LOD) was 0.18 ${\mu}g/L$ for chlorite ion.

  • PDF