• 제목/요약/키워드: initial relative density

검색결과 105건 처리시간 0.024초

Effect of relative density on the shear behaviour of granulated coal ash

  • Yoshimoto, Norimasa;Wu, Yang;Hyodo, Masayuki;Nakata, Yukio
    • Geomechanics and Engineering
    • /
    • 제10권2호
    • /
    • pp.207-224
    • /
    • 2016
  • Granulated coal ash (GCA), a mixture of the by-product from milling processes with a small amount of cement added, has recently come to be used as a new form of geomaterial. The shear strength and deformation behaviours of GCA are greatly determined by its relative density or void ratio. A series of drained triaxial compression tests were performed on cylindrical specimens of GCA at confining pressures of between 50 kPa and 400 kPa at initial relative densities of 50%, 70% and 80%. Experimental results show that a rise in relative density increases the peak shear strength and intensifies the dilation behaviour. The initial tangent modulus and secant modulus of the stress-strain curve increase with increasing initial relative density, whereas the axial and volumetric strains at failure decrease with level of initial relative density. The stress-dilatancy relationships of GCA at different relative densities and confining pressures display similar tendency. The dilatancy behaviour of GCA is modelled by the Nova rule and the material property N in Nova rule of GCA is much larger than that of natural sand.

Apparent Densification Rate and Initial Permeability of NiCuZn Ferrite Depended on Relative Packing Density (NiCuZn Ferrite의 겉보기 고화속도와 초기투자율의 충진율 의존성에 관한 연구)

  • 류병환;이정민;고재천
    • Resources Recycling
    • /
    • 제7권4호
    • /
    • pp.27-34
    • /
    • 1998
  • In this research, the processing control of NiCuZn Ferrite (NCZF) had been studied. NiCuZn Ferrite, which calcined at $700^{\circ}C$ for 3 bours, was ball milled for about 60 hours to ill김ke a size of $0.5\mu\;extrm{m}$ followed by granulation using spray dryer Apparent densincatioo rate and initial permeability of NiCuZn Ferrite with an initial packing density had been investigated as f follows. 1.The relative packing density of NCZF green body increas$\xi$d in the range of 48.6-56.8% with an increased forming pressure of 20-170 MPa. 2. The higher the relative pac퍼ng density of NCZF and the sintering temperature are, the higher the initial densification rate. The increased bulk rlcnsity of NCZF was attributed to the densification rate with decreased open pore and increased closed pore as the relative packing density, sintering temperature, and sinteriog tim$\xi$ increased. 3. The initial P permeability of NCZF with constant composition is logarithmically proportional to the bulk density of NCZF sintered at $875~925^{\circ}C$ for 0-5h, and strongly depended on the relative packing density of NCZF green body. The empirical equation is as f follows; log $\mu$i=$G1{\times}BD$+$G2{\times}RPD$+b(0);where, G1, G2; gradient, B.D: bulk density, RPD; relative packing density, b(0); intercept.

  • PDF

Estimation on Unsaturated Hydraulic Conductivity Function of Jumoonjin Sand for Various Relative Densities (주문진 표준사의 상대밀도에 따른 불포화 투수계수함수 산정)

  • Song, Young-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제33권6호
    • /
    • pp.2369-2379
    • /
    • 2013
  • The Soil-Water Characteristics Curve (SWCC) is affected by the initial density of soil under unsaturated condition. Also, the characteristic of hydraulic conductivity is changed by the initial density of soil. To study the effect of initial density of unsaturated soil, SWCC and the Hydraulic Conductivity Function (HCF) of Jumoonjin sand with various relative densities, 40%, 60% and 75% were measured in both drying and wetting processes. As the results of SWCC estimated by van Genuchten (1980) model, the parameter related to Air Entry Value(AEV), ${\alpha}$ in the wetting process is larger than that in drying process, but the parameters related to the SWCC slope, n and the residual water content, m are larger than those in wetting process. The AEV is increased or Water Entry Value (WEV) is decreased with increasing the relative density of sand. The AEV is larger than the WEV at the same relative density of sand. As the results of HCF estimated by van Genuchten (1980) model which is one of the parameter estimation methods, the unsaturated hydraulic conductivity maintained at a saturated one in the low level of matric suctions and then suddenly decreased just before the AEV or the WEV. The saturated hydraulic conductivity in drying process is larger than that in wetting process. The saturated hydraulic conductivity is decreased with increasing the relative density of sand in both drying and wetting processes. Also, the hysteresis in unsaturated HCFs between drying and wetting process was occurred like the hysteresis in SWCCs. According to the test results, the AEV on SWCC is decreased and the saturated hydraulic conductivity is increased with increasing the initial density. It means that SWCC and HCF are affected by the initial density in the unsaturated soil.

A Study on the Evaluation of Liquefaction of Sandy Soils by the Cyclic Triaxial Compression Test (反復三軸壓縮試驗에 의한 砂質土의 液狀化 評價에 관한 硏究)

  • Koh, Jae-Man;Doh, Duk-Hyun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • 제33권3호
    • /
    • pp.51-62
    • /
    • 1991
  • A comprehensive laboratory investigation of the liquefaction characteristics of Jumunjin standard sand. Seoul sand and Hongsung sand was peformed by the undrained cyclic triaxial compression test under different relative densities, confining pressures and cyclic deviator stresses. The results obtained are as follows ; 1. Liquefaction potential was dominated by the stress ratio at a given number of cycle. That is, the number of cycle required to cause initial liquefaction became samller as the stress ratio increased. 2. Liquefaction potential of a sand was infliuenced by initial relative density or void ratio. Under a given relative density. liquefaction potential of Jumunjin standard sand and Seoul sand was smaller than that of Hongsung sand. 3. The pore pressure ratio of Hongsung sand was the smallest three under a given relative density and stress ratio, and it showed higher value when the cyclic stress and the shear strain were high. 4. An excessive pore pressure ratio not found when initial shear was smaller than 0.01%, and the pore pressure ratio started to increase when initial shear became greater than 0.01%. 5. Soil texture is an important factor to cause liquefaction, and liquefaction potential decreased a the mean grain size decreased. however the sand having fine grain such as Hongsung sand showed somewhat higher liquefaction potential. 6. Based on the analysis of the specimens whose number of the cycles to cause liquefaction was 8~12, it was found that the relationship between density and stress ratio was linear. The curves for Hongsung sand was steeper than the other. 7. From the above results and the method suggested by Seed-Idriss, it may be considered that the damages by Hongsung earthquake was not directly caused by liquefaction.

  • PDF

Undrained Behavior on Saemangeum Dredged Sands (새만금 준설모래의 비배수 거동)

  • Jeong, Sang-Guk;Kang, Kwon-Soo;Yang, Jae-Hyouk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제6권1호
    • /
    • pp.193-203
    • /
    • 2002
  • The results of an experimental study on Saemangeum dredged sands are presented. Undrained triaxial compression tests were performed with there different initial relative densities, namely 18, 34, and 50%, intend to evaluate undrained Behavior. All undrained triaxial compression tests were performed under static loading conditions. Undrained triaxial compression tests were exhibited complete static liquefaction, zero effective confining pressure and zero stress difference at lower confining pressures. As confining pressures were increased, the effective stress paths indicated increasing resistance to static liquefaction by showing increasing dilatant tendencies. The fines and larger particles create a particle structure with high compressibility at lower confining pressure. The effect of increasing relative density was to increase the resistance of the sand against static liquefaction by making the sand more dilatant.

Strength Characteristics in Drained Triaxial Tests on Granular Materials (사질토의 배수삼축압축시험에서의 강도특성)

  • 장병유;송창섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • 제34권3호
    • /
    • pp.33-42
    • /
    • 1992
  • The shear strength of cohesionless Soils results from particle-to-particle friction and structural resistance by interlocking. And, the shear strength of soils is subjected to vary depending on the internal states and external condtions. If the volume change occurring in the soils and stress-strain relationships under the internal and external changes can accrurately he described, it is possible to predict the behaviors of soils. To accomplish these objectives a series of drained triaxial compression tests and isotropic compression test was performed on the Banwol sand at different relative densities ranging from 20% to 80% and different confining pressures ranging from 0.4kgf/cm$^2$ to l2kgf/cm$^2$. The results and main conclusions of the study are summarized as follows; 1.When the relative density or the confining pressure is increased, the maximum deviator stress is increased. The ratio of the maximum deviator stress and the confining pressure is linearly proportional to the relative density. 2.It is observed that the dilatancy depends not only upon its relative density but also the confining stress, and that the maximum deviator stress is obtained after the diatancy occurs. 3.The volume of sands undergoes initial contraction prior to the dilatancy occurred by strain softening. The dilatancy rate eventually approaches the critical state or a constant volume. 4.At lower strains, Poisson's ratio approaches a certain minimum value regadless of the state of materials. At larger strains, however, the ratio is increased as the relative density is increased. 5.It is observed that the modulus of elasticity is linearly proportional to the relative density and the pressure. 6.When the relative density is increased, the friction angle of sands is linearly increased. 7.When the relative density is increased, the expansion index and the compression index are linearly decreased, and the ratio of the two is about 1/3.

  • PDF

ANALYSIS OF FORGING LIMIT FOR SINTERED POROUS METALS (다공성 소결금속의 단조한계해석)

  • 한흥남;오규환;이동녕
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 1995년도 제2회 단조심포지엄 단조기술의 진보
    • /
    • pp.64-73
    • /
    • 1995
  • The forging limit curves of sintered porous metals have been calculated, in terms of the two principal strains, by the Lee-Kuhn initial imperfection model. The various yield functions for porous metal have been applied to the initial imperfection model. When the value of initial imperfection ratio equals the value of initial relative density of the sintered porous metals, the calculation values are in good agreement with the measured data. The slopes of the forging limit curves are about 0.5 as in the case of non-porous metals.

Analysis of Densification Behavior during Powder Equal Channel Angular Pressing using Critical Relative Density Model (임계상대밀도 모델을 이용한 분말 등통로각압축 공정시 분말 치밀화 거동)

  • Bok, Cheon-Hee;Yoo, Ji-Hoon;Yoon, Seung-Chae;Kim, Taek-Soo;Chun, Byong-Sun;Kim, Hyoung-Seop
    • Journal of Powder Materials
    • /
    • 제15권5호
    • /
    • pp.365-370
    • /
    • 2008
  • In this study, bottom-up powder processing and top-down severe plastic deformation processing approaches were combined in order to achieve both full density and grain refinement with least grain growth. The numerical modeling of the powder process requires the appropriate constitutive model for densification of the powder materials. The present research investigates the effect of representative powder yield function of the Shima-Oyane model and the critical relative density model. It was found that the critical relative density model is better than the Shima-Oyane model for powder densification behavior, especially for initial stage.

A Study on the Influence Factors for Liquefaction Based on the Disturbed State Concept (DSC 이론을 기초로 한 액상화 영향인자들에 관한 연구)

  • 박인준
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.361-368
    • /
    • 1998
  • The purpose of this study is to find out the factors affacting liquefaction potential by using DSC(disturded state concept) method and to verify these results through cyclic shear test (truly triaxial test and cyclic triaxial) on saturated sandy soil. Based on this reserch, the DSC method predictions were found to provide satisfactory correlation with the cyclic shear test. And the relationship between the factors affecting liquefaction characteristics--relative density(Dr0 and initial effective confining pressure and physical properties of the saturated sand --ξD and Dc--is found. If the relative density and the initial effective confining pressure increase, the number of cyclic grows up. This means that Dc is incresed and ξD is decreased. Therefore, the liquefaction potential can be evaluated and the factors affacting liquefaction potential can be investigated by using on DSC method. Finally, it is shown that the DSC method can capture the liquefaction mechanism.

  • PDF

Forecasting the Pepper Gray Mold Rot to Predict the Initial Infection by Botrytis cinerea in Greenhouse Conditions

  • Park, Seon-Hee;Lee, Joon-Taek;Chung, Sung-Ok;Kim, Hee-Kyu
    • The Plant Pathology Journal
    • /
    • 제15권4호
    • /
    • pp.158-161
    • /
    • 1999
  • We determined threshold environmental factros to initiate infection of pepper plants by Botrytis cinerea, a fungal pathogen of pepper gray mold, in two greenhouse conditions. A new efficient spore-trapping method was developed to estimate population density of airborne conidia in the greenhouses, and spore release was measured using a Kerssies' selective medium. At a given day, spores were released greater during daytime (mostly from 7:30 am to 10:30 am and at 4:30 pm) than nighttime. Diurnal and nocturnal temperatures in the greenhouse-1 were about $25^{\circ}$ and $17^{\circ}$,and relative humidity was 100% for prolonged 24 h due to rain on December 17, 1997. Population density of air-borne conidia was 3.0$\times$103 conidia/ $0.5\textrm{m}^3$ after two days, and the initial infection occurred in ten days. During the same period of time in the greenhouse-2, diurnal temperature was about $25^{\circ}$ and nocturnal temperature was below $15^{\circ}$, and population density of air-borne conidia was 104 conidia/ $0.5\textrm{m}^3$. Under these conditions, the initial infection started in three days. This indicates that the early infection occurs under which diurnal temperature is approximately $25^{\circ}$, nocturnal temperature is maintained below $15^{\circ}$, and population density of air-borne conidia is 104 conidia/ $0.5\textrm{m}^3$ at saturated relative humidity condition.

  • PDF