• Title/Summary/Keyword: initial permeability

Search Result 293, Processing Time 0.032 seconds

The Prodessing Control of NiCuZn Ferrite(II) - The Relationship between Initial Permeability and Bulk Density of NiCuZn Ferrite as Functions of Forming Pressure and Sintering Temperature. (NiCuZn Ferrite의 제조공정 제어(제2보) - 성형압력 및 소성온도 변화에 따른 초기투자율과 겉보기밀도에 관한 고찰)

  • 류병환;김선희;최경숙;고재천
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.6
    • /
    • pp.937-946
    • /
    • 1995
  • In this research, the processing control of NiCuZn Ferrite has been developed. The relationship between initial permeability and bulk density of NiCuZn Ferrite with processing factors was studied. NiCuZn Ferrite, which calcinated at $700^{\circ}C$ for 3 hours, was ball milled for about 60 hours to make a size of $0.5\mu\textrm{m}$ followed by granulation using spray dryer. The physical properties and the magnetic properties of NiCuZn Ferrite were investigated with the processing factor, such as (i) granule size and forming pressure, and (ii) sintering temperature. The green density of NiCuZn Ferrite was largely depended on the forming pressure rather than its granule size. The green density of NiCuZn Ferrite was increased from $2.484\;g/cm^{3}$ to $3.002\;g/cm^{3}$ with increase in forming pressure. The bulk density of NiCuZn Ferrite was increased from $3.470\;g/cm^{3}$ to $4.754\;g/cm^{3}$ linearly with increase in sintering temperature. The relationship between initial permeability and bulk density of NiCuZn Ferrite was expressed with the empirical equation,$\mu_{i}=a+b_{\rho}+c_{\rho}^2$ at forming pressure and sintering temperature.

  • PDF

Blend Films of Poly(acrylic acid-co-maleic acid) with Poly(vinyl alcohol) (I) : Thermo-mechanical Properties and Gas Permeability (폴리(비닐 알코올)과 폴리(아크릴산-말레산) 공중합체의 블렌드 필름 (I) : 열적-기계적 성질 및 가스 투과도)

  • Ham Shin-Kyun;Jung Min-Hye;Chang Jin-Hae
    • Polymer(Korea)
    • /
    • v.30 no.4
    • /
    • pp.298-304
    • /
    • 2006
  • Blends of poly (acrylic acid-co-maleic acid)(PAM) with poly (vinyl alcohol)(PVA) were obtained by solution blending. The blends were solvent-on to a film to examine thermo-mechanical properties and gas permeability. The transition temperatures $(T_g\;and\;T_m)$ of the blends remained constant regardless of PAM contents. However, the values of enthalpy changes corresponding to melting transition $({\Delta}H_m)$ and initial degradation temperature $({T_D}^i)$ were decreased with increasing PAM content. The values of ultimate strength and initial modulus gave the maximum value at the 12 wt% PAM then decreased with further increase of PAM content up to 15 wt%. To measure the gas permeability of the PVA/PAM blend films, the PVA blend solutions were coated onto both biaxially oriented propylene (BOPP) and poly (ethylene terephthalate)(PET) films. The oxygen transmission rate $(O_2\;TR)$ permeability values mono- tonically decreased with increasing PAM content. However, moisture vapor transmission rate was not affected by PAM content.

Assessment on Consolidation Material Function and Initial Stress for Soft Ground by Hydraulic Fill the at Southern Coast of Korea (남해안 준설매립 연약지반에 대한 압밀 물질함수 및 초기응력 산정)

  • Jeon, Je Sung;Koo, Ja Kap
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.136-145
    • /
    • 2011
  • For a massive project related to building national industrial complexes on a soft ground applied to PVD after dredging and hydraulic fill, laboratory tests were carried out using undisturbed sample taken from various depth. Piezocone penetration and dissipation tests were carried out to assess horizontal coefficient of consolidation and initial stress in field. The ground consists of upper dredged fill and lower original clay layer having both similar marine clays. It should be, however, considered as multi-layered soft ground having different initial void ratio, initial water content, initial effective stress, and permeability and compressibility with directions. To assess initial stress of those soft layers in which have different stress history related to consolidation, CPTu test results, especially excess pore water pressure, were analyzed. It allows to find out distribution of excess pore water pressure and initial stress inner original clay layer.

Characteristics of Material Function Related to Permeability and Compressibility for Soft Clay Ground (투수 및 압축에 대한 연약 점토지반의 물질함수 특성)

  • Lee, Song;Jeon, Je-Sung;Yi, Chang-Tok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.183-194
    • /
    • 2004
  • It's essential process to study non-linear material function related to characteristics of compressibility and permeability when we predict the consolidation behavior of soft clay ground. In this study, laboratory tests were conducted to find out the material function using marine clay. Standard oedometer test and Rowe cell test were performed with conditions, which were classified into vertical drainage only, radial drainage only and vertical-radial drainage case. Modified oedometer test equipment was developed to find out the material function and special extrusion device was originated to minimize the sample disturbance effect. Reliability of the results in modified oedometer test could be confirmed by comparing with the Rowe cell's one. Effective stress - void ratio - permeability relations were analyzed using all testing results. As a result, void ratio with effective stress level could be expressed by the power function and permeability with void ratio could be expressed by exponential function. In soft clay with high initial water content and low shear strength, non-linear characteristics related to compressibility and permeability varied with wide range by the effective stress levels. It's important to note that non-linearity of the material function should be considered at prediction of the consolidation behavior.

The Mortar Properties of Portland Cements Blended with Modified Coal Ashes (가공된 석탄재를 사용한 석탄재혼합시멘트의 모르터 특성)

  • 홍원표;노재성;조헌영;정수영;김무한
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.7
    • /
    • pp.833-840
    • /
    • 1990
  • For the development of multi-functional materials which has water reducing power, air entraining power and waterproofing power as well as blending additive in cement mortar the coal ash was modified with asphalt-stearic acid or asphalt-boiled oil mixtures by mechanical treatment. And the physical properties of cement mortar blended with modified coal ashes were compared with those of the water-tightness-cement mortar and the ordinary-portland-cement mortar added with AE.water reducing agent. The mortar of coalash-blend-cement modified with asphalt-stearic mixture was increased acid about 20% in initial strengths and decreased about 20% in water absorption ratio than those of ordinary coalash-blend-cement. The mortar of coalash-blend-cement modified with asphalt-bolied oil mixture was similar to the cement mortar added with AE.water reducing agent in water reduction ratio, air entraining conents and the initial strengths, also was similar to the water-tightness-cement mortar in water absorption and water permeability ratios.

  • PDF

The Evaluation of Drainage Characteristics Using a New Drainage Tester (새로운 탈수측정 설비를 이용한 탈수 특성 평가)

  • 김용식;원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.3
    • /
    • pp.1-9
    • /
    • 2000
  • The MDDA (Modified Dynamic Drainage Analyzer) was developed to evaluate the drainage characteristics on paper machine. The initial forming vacuum velocity was decreased with the increase of stock consistency and there were no significant effects of the applied vac-uum. On the other hand the initial forming drainage velocity was rapidly decreased with the increase of stock consistency above the 0.35 bar of applied vacuum. The final drainage time and wet web permeability showed similar trends under 0.075% consistency but increased rapidly at the higher consistencies. SFR(Specific Filtration Resistance) and drainage obtained for different vacuum level applied and deposited weights measured by using MDDA showed the linear relationship.

  • PDF

Study on manufacturing and operating characteristics of Magnetic cores for Flat TR (Flat TR용 핵심 쿄아의 제조와 동작 특성 안정화 연구)

  • Han, Se-Won;Cho, Han-Goo;Yu, Dong-Uk;Ryu, Mung-Ho;Choi, Kwang-Bo;Kim, Sung-Ba
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.23-26
    • /
    • 2003
  • The flat transformer, typically, has a number of parallel single turn secondary windings. Each secondary winding is coupled to the same primary winding. Therefore, the current in each secondary winding is equal to the ampere-turns in the primary winding, and to each other. These characteristics are particularly advantageous where parallel rectifiers are used. The windings share the current equally, with no need for ballast resistors or other added components. In this study, the ferrite magnetic core samples of Mn-Zn system for the Flat transformer are manufactured and the electrical and magnetic characteristics of its tested. The density of sample FO2-2 sintered at $1350^{\circ}C$ is $4.00kg/m^3$, which shows the good microstructural state. The initial permeability and saturation flux density of FO2 at room temperature is 2700 and 510mT, individually. The power loss of FO2 samples at 250kHz have been ranged $350kW/m^3$ to $80kW/m^3$ with temperature. And the minimum power loss of sample FO2-2 showed at $70^{\circ}C$, which property seems very positive to apply for a flat transformer.

  • PDF

Durability assessment of self-compacting concrete with fly ash

  • Deilami, Sahar;Aslani, Farhad;Elchalakani, Mohamed
    • Computers and Concrete
    • /
    • v.19 no.5
    • /
    • pp.489-499
    • /
    • 2017
  • Self-Compacting Concrete (SCC) is a new technology capable to flow without segregation or any addition of energy which leads to efficient construction and cost savings. In this study, the effect of replacing the Ordinary Portland Cement (OPC) with Fly Ash (FA) on the strength, durability of the concrete was investigated experimentally, and carbon footprint and cost were also assessed. Four different replacement FA ratios (0%, 20%, 40% and 60%) were used to create four SCC mixes. Standard test methods were used to determine the workability, strength, and durability of the SCC mixes including resist chloride ion penetration, water permeability, water absorption, and initial surface absorption. The axial cube compressive strength tests were performed on the SCC mixes at 1, 7, 14, 28 and 35 days. Replacing the OPC with FA had a significant positive impact on chloride iron penetration resistance and water absorption but had a considerable negative impact on the compressive strength. The SCC mix with 60% FA had 36.7% and 15.8% enhancement in the resistance to chloride ion penetration and water absorption, respectively. Evaluation of the carbon footprint and the cost of each SCC mixes showed the $CO_2$ emissions mixes 1, 2, 3 and 4 were significantly reduced by increasing the FA content from 0% to 60%. Compared with the control mix, the cost of all mixes increased when the FA content increased, but no significant differences were seen between the estimated costs of all four mixes.

The Effect of Composition on the Properties of NiCuZn ferrites (NiCuZn ferrite의 특성에 미치는 조성의 영향)

  • 남중희;정현학;신재영;오재희
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.191-196
    • /
    • 1995
  • NiCuZn ferrites were prepared by a solid-state reaction and sintered at $900^{\circ}C$ for 5 hours. Its properties were investigated by controlling the ferrite composition and processing. NiCuZn ferrite with a composition of ${(Ni_{0.2}Cu_{0.2}Zn_{0.6}O)}_{1.02}{(Fe_{2}O_{3})}_{0.98}$ was found to have the maximum initial permeability as a result of the variation of Cu content and the (Ni+Cu)/Zn ratio. Curie temperature($T_{c}$) of NiCuZn ferrite was decreased with the larger Cu content and increased with the larger Ni content. NiCuZn ferrites of ${(Ni_{0.2}Cu_{0.2}Zn_{0.6}O)}_{1-w}{(Fe_{2}O_{3})}_{1+w}$ composition milled for 20~80 hours had the maximum initial permeability at w=-0.015 and Curie temperature ($T_{c}$) was decreased with the increasing of $Fe_{2}O_{3}$ deficiency(w).

  • PDF

Separation of Cd(II) from Aqueous Solutions by A New Consecutive Process Consisting of Supported Liquid Membrane and Electrodialysis

  • Altin, Sureyya;Altin, Ahmet
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.14-21
    • /
    • 2019
  • Supported liquid membrane process usually is used for recovering or enrichment of valuable metals in the industrial wastewater. But, even if the metals in the wastewater was separated with high chemical selectivity, it cannot be enough concentrated since separation performance of supported liquid membrane (SLM) process is limited by concentration gradient between feed solution and stripping solution. If metal concentration in the stripping solution to be enough low, transport of metal through membrane can be accomplishment constantly. Therefore, Electrodialysis (ED) has been placed after SLM process and the stripping solution of SLM was used as the feed solution for the ED process. Transport of ions in the solutions is successfully performed by ED process. Thus, the metal concentration in the stripping solution does not rise as to stop ion transport. Besides, valuable metals easily are concentrated by ED process for re-use. In this study, effects of operation parameters like initial Cd(II) concentration, HCl concentration in the feed solution of SLM and applied voltage are investigated on separation efficiency, flux and permeability of the both processes. As the feed solution concentration increased, all performance values has increased. When initial concentration of 100 mg/L is used, separation performances (SP) are 55% and 70%, for SLM and consecutive process, respectively. The best HCl concentration in the feed solution of SLM has determined as 2 M, in this conditions SP are 64% and 72%, for SLM and consecutive process, respectively. With increased of applied voltage on ED process, SP of the consecutive process has been raised from 72% to 83%. According to the obtained experimental data, consecutive process has better separation performance than SLM. When the separation performances of both processes were compared for the same operating conditions, it was determined higher the separation efficiency, permeability and flux values of the consecutive process, 8%, 9% and %10.6, respectively. Consequently, the use of the consecutive process increases the performance efficiency of both processes. The consecutive process studied has quite a good chemical separation efficiency, and enrichment capability. Moreover, this process requires few water and energy.