• 제목/요약/키워드: initial equilibrium state

검색결과 94건 처리시간 0.036초

Experimental study on fire performance of axially-restrained NSC and HSC columns

  • Wu, Bo;Li, Yi-Hai
    • Structural Engineering and Mechanics
    • /
    • 제32권5호
    • /
    • pp.635-648
    • /
    • 2009
  • This paper describes fire performance of eight axially restrained reinforced concrete (RC) columns under a combination of two different load ratios and two different axial restraint ratios. The eight RC columns were all concentrically loaded and subjected to ISO834 standard fire on all sides. Axial restraints were imposed at the top of the columns to simulate the restraining effect of the rest of the whole frame. The axial restraint was effective when the column was expanding as well as contracting. As the results of the experiments have shown, the stiffness of the axial restraint and load level play an important role in the fire behaviors of both HSC and NSC columns. It is found that (a) the maximum deformations during expanding phase were influenced mostly by load ratio and hardly by axial restraint ratio, (b) For a given load ratio, axial restraint ratio had a great impact on the development of axial deformation during contraction phase beyond the initial equilibrium state, (c) increasing the axial restraint increased the value of restraint force generated in both the NSC and HSC columns, and (d) the development of column axial force during the contracting and cooling phase followed nearly parallel trend for columns under the same load ratio.

교란들의 인과관계구현 데이터구조에 기초한 발전소의 고장감시 및 고장진단에 관한 연구 (Power Plant Fault Monitoring and Diagnosis based on Disturbance Interrelation Analysis Graph)

  • 이승철;이순교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권9호
    • /
    • pp.413-422
    • /
    • 2002
  • In a power plant, disturbance detection and diagnosis are massive and complex problems. Once a disturbance occurs, it can be either persistent, self cleared, cleared by the automatic controllers or propagated into another disturbance until it subsides in a new equilibrium or a stable state. In addition to the Physical complexity of the power plant structure itself, these dynamic behaviors of the disturbances further complicate the fault monitoring and diagnosis tasks. A data structure called a disturbance interrelation analysis graph(DIAG) is proposed in this paper, trying to capture, organize and better utilize the vast and interrelated knowledge required for power plant disturbance detection and diagnosis. The DIAG is a multi-layer directed AND/OR graph composed of 4 layers. Each layer includes vertices that represent components, disturbances, conditions and sensors respectively With the implementation of the DIAG, disturbances and their relationships can be conveniently represented and traced with modularized operations. All the cascaded disturbances following an initial triggering disturbance can be diagnosed in the context of that initial disturbance instead of diagnosing each of them as an individual disturbance. DIAG is applied to a typical cooling water system of a thermal power plant and its effectiveness is also demonstrated.

ON A TIME-CONSISTENT SOLUTION OF A COOPERATIVE DIFFERENTIAL TIME-OPTIMAL PURSUIT GAME

  • Kwon, O-Hun;Svetlana, Tarashinina
    • 대한수학회지
    • /
    • 제39권5호
    • /
    • pp.745-764
    • /
    • 2002
  • In this paper we Study a time-optimal model of pursuit in which the players move on a plane with bounded velocities. This game is supposed to be a nonzero-sum group pursuit game. The main point of the work is to construct and compare cooperative and non-cooperative solutions in the game and make a conclusion about cooperation possibility in differential pursuit games. We consider all possible cooperations of the players in the game. For that purpose for every game $\Gamma(x_0,y_0,z_0)$ we construct the corresponding game in characteristic function form $\Gamma_v(x_0,y_0,z_0)$. We show that in this game there exists the nonempty core for any initial positions of the players. The core can take four various forms depending on initial positions of the players. We study how the core changes when the game is proceeding. For the original agreement (an imputation from the original core) to remain in force at each current instant t it is necessary for the core to be time-consistent. Nonemptiness of the core in any current subgame constructing along a cooperative trajectory and its time-consistency are shown. Finally, we discuss advantages and disadvantages of choosing this or that imputation from the core.

커피 찌꺼기를 흡착제로 한 니켈 폐수 처리 특성 (Treatment Features of Ni Wastewater by using Coffee Grounds as the Adsorbent)

  • 서명순;김동수
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.14-20
    • /
    • 2005
  • A feasibility study has been conducted regarding the application of waste coffee grounds as an adsorbent for the treatment of nickel ion containing wastewater. The major variables which considered to influence the adsorbability of nickel ion were its initial concentration, reaction temperature, pH, and coexisting ion. The specific surface area of coffee grounds used in the experiment was found to be ca. $39.67m^2/g$, which suggesting its potential applicability as an adsorbent due to its relatively high surface area. In the experimental conditions, more than 90% of the initial amount of nickel ion was shown to adsorb within 15 minutes and equilibrium in adsorption was attained after 3 hours. The adsorption behavior of nickel ion was well explained by Freundlich model and kinetics study showed that the adsorption reaction was second-order. Adsorption was reduced with temperature and its change of enthalpy in standard state was estimated to be -807.05 kJ/mol. Arrhenius equation was employed for the calculation of the activation energy of adsorption and nickel ion was observed to adsorb on coffee grounds exoentropically based on thermodynamic estimations. As pH rose, the adsorption of nickel ion was diminished presumably due to the formation of cuboidal complex with hydroxide ion and the coexistence of cadmium ion was found to decrease the amount of nickel ion adsorption, which was proportional to the concentration of cadmium ion.

CRITICAL FLOW EXPERIMENT AND ANALYSIS FOR SUPERCRITICAL FLUID

  • Mignot, Guillaume;Anderson, Mark;Corradini, Michael
    • Nuclear Engineering and Technology
    • /
    • 제40권2호
    • /
    • pp.133-138
    • /
    • 2008
  • The use of Supercritical Fluids(SCF) has been proposed for numerous power cycle designs as part of the Generation IV advanced reactor designs, and can provide for higher thermal efficiency. One particular area of interest involves the behavior of SCF during a blowdown or depressurization process. Currently, no data are available in the open literature at supercritical conditions to characterize this phenomenon. A preliminary computational analysis, using a homogeneous equilibrium model when a second phase appears in the process, has shown the complexity of behavior that can occur. Depending on the initial thermodynamic state of the SCF, critical flow phenomena can be characterized in three different ways; the flow can remain in single phase(high temperature), a second phase can appear through vaporization(high pressure low temperature) or condensation(high pressure, intermediate temperature). An experimental facility has been built at the University of Wisconsin to study SCF depressurization through several diameter breaks. The preliminary results obtained show that the experimental data can be predicted with good agreement by the model for all the different initial conditions.

스트럿 타이 모델개발을 위한 시각화 도구 개발 (Development of Visual Tools for Strut-Tie Model)

  • 김남희;홍성걸;여득현
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.596-601
    • /
    • 2008
  • This paper presents how to develop visual design tools for construction of strut-and-tie models(S (STM). STMs have shown internal force flows for dimensioning and proportioning of D-regions of reinforced concrete structures. In order to select an appropriate strut-and-tie model some interactive graphic tools are necessary to help designers compare alternatives by changing the geometry of initial STM. This study proposes to use force polygons representing the equilibrium state of STM. The change of STM dynamically shows change of force magnitudes by force polygon. Once the geometry of STM is determined the detailing design process is required in the next procedure.

  • PDF

안동 흑운모화강암 지역의 진행성 파괴사면 안정성 평가 (Stability Evaluation of Progressive Failure Slope in Biotite Granite Area of Andong)

  • 백승철
    • 한국안전학회지
    • /
    • 제15권2호
    • /
    • pp.103-110
    • /
    • 2000
  • This paper deal with the stability evaluation and suggestion of progressive failure slope in biotite granite area of Andong. Based on geological site investigation and field test, stability analysis of slope was performed in conjunction with limit equilibrium methods and stereographic projection. Additionally, initial design and construction procedure was critically evaluated. Series of the slope stability analysis reveals the detection of local wedge and plane failure under the current slope condition. It is additionally appeared that a certain synthetic behavior of circle and plane failure exists on the right spot where the overall failure's going in progress. In order to construct more stable slope based on the suitability for the real state of the slope circumstances, this study issues a solution to eliminate the primary factors which cause the instability, by means of the grade of weathering and RMR classification of rock mass.

  • PDF

Nonlinear analysis of cable-supported structures with a spatial catenary cable element

  • Vu, Tan-Van;Lee, Hak-Eun;Bui, Quoc-Tinh
    • Structural Engineering and Mechanics
    • /
    • 제43권5호
    • /
    • pp.583-605
    • /
    • 2012
  • This paper presents a spatial catenary cable element for the nonlinear analysis of cable-supported structures. An incremental-iterative solution based on the Newton-Raphson method is adopted for solving the equilibrium equation. As a result, the element stiffness matrix and nodal forces are determined, wherein the effect of self-weight and pretension are taken into account. In the case of the initial cable tension is given, an algorithm for form-finding of cable-supported structures is proposed to determine precisely the unstressed length of the cables. Several classical numerical examples are solved and compared with the other available numerical methods or experiment tests showing the accuracy and efficiency of the present elements.

막 구조물에 관한 형상 탐색과 재단도 결정법 (A Shape Finding and Cutting Pattern Determination for Membrane Structures)

  • 최호;이장복;김재열;서삼열;권택진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.175-182
    • /
    • 1998
  • The object of this study is shape finding and cutting pattern generation of membrane structures under the following assumptions : (1) material is linearly elastic (2) stress state is plane stress. Cable and membrane structures should introduce the nonlinear analysis considering geometric nonlinearity because these structures deform largely under the external loads. The analysis procedure is consisted of three steps considering geometric nonlinearity unlike any other structures. First step is the shape finding analysis to determine the initial equilibrium shape. Second step is the stress-deformation analysis to investigate the behaviors of structures under various external loads. Once a satisfactory shape has been found, a cutting pattern based on the shape finding analysis may be generated from the view point of construction. In this paper, (1) shape finding analysis formulation and an example, (2) cutting pattern determination procedure using weighted least-square minimization flattening method and some results are presented.

  • PDF

막 구조물의 재단 패턴 결정에 관한 연구 (A Study on the Cutting Pattern Determination for Fabric Structures)

  • 최호;이장복;김재열;서삼열;권택진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.266-273
    • /
    • 1998
  • The object of this study is shape finding and cutting pattern generation of membrane structures under the following assumptions: (1) material is linearly elastic (2) stress state is plane stress. Cable and membrane structures should introduce the nonlinear analysis considering geometric nonlinearity because these structures deform largely under the external loads. The analysis procedure is consisted of three steps considering geometric nonlinearity unlike any other structures. First step is the shape finding analysis to determine the initial equilibrium shape. Second step is the stress-deformation analysis to investigate the behaviors of structures under various external loads. Once a satisfactory shape has been found, a cutting pattern based on the shape finding analysis may be generated from the view point of construction. In this paper, after shape finding analysis, cutting pattern determination procedure using weighted least-square minimization flattening method and some results are presented.

  • PDF