• 제목/요약/키워드: initial defect

검색결과 278건 처리시간 0.025초

Effect of Small Surface Defects in the Starting Material on Product Quality after Drawing (원소재의 미소 표면결함이 인발공정에 미치는 영향)

  • Nam, C.H.;Lee, I.K.;Lee, J.K.;Joun, M.S.
    • Transactions of Materials Processing
    • /
    • 제23권3호
    • /
    • pp.159-163
    • /
    • 2014
  • In the current study, the effect of small surface defects in the starting material including roughness, indentations, or scratches, which are perpendicular to the direction of drawing, on the product quality is investigated using the finite element method. An axisymmetric defect is assumed. Such defects are defined by a cylindrical defect area and two tapered regions connecting the defect area to the non-defective area of the material. Various conditions for these initial surface defects are considered, including defect depth, defect slope and defect length. To describe the plastic deformation of the defect in detail during the simulation, local remeshing is applied. Based on the finite element results, defect disappearance maps were generated. It was found that defect disappearance is significantly dependent on the defect depth and the defect length coupled with the defect slope.

Long-term radiographic evaluation of infrabony defect treated by flap operation (치주판막술에 의해 치료된 골연하 결손부의 장기적 방사선학적 변화 양사의 관찰)

  • Bae, Sang-Ryul;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.429-436
    • /
    • 2008
  • Purpose: The goal of periodontal regenerative therapy is to replace bone, cementum, and periodontal ligament on a previously diseased root surface, which has suffered the loss of these supporting structures. To accomplish the regeneration, a number of surgical procedures have been advocated throughout the years. There seems to be a potential for some spontaneous periodontal tissue regeneration in the bottom of periodontal defect following open flap debridement alone. The aim of this study was to analyse the radiographic bone changes over 2-year after flap operation. Material and Methods: Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients had clinical and radiographic evidence of infrabony defect(s). forty two sites of 33 patients aged 26 to 65 (mean age 45.5) were treated by flap operation with or without osseous surgery. Baseline and over 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, gender, defect depth, defect angle) using the paired t-test were examined. Result: We observed 0.74 mm of bone fill, 0.66 mm of crestal resorption, 1.40 mm of defect resolution, and 27% of percentage of defect resolution. Mandible, women, deeper initial defect depth, narrower initial defect angle showed greater bone fill, defect resolution, and % of defect resolution. Conclusion: The results of this study suggest that the use of flap operation did enhance the outcome in terms of radiographically detectable bone fill. Both treatment resulted in some loss of crestal bone height.

Radiographic evaluation of infra-bony defects treated by bone graft procedures (골 이식술에 의해 치료된 골연하 결손부의 방사선학적 변화 양상의 관찰)

  • Ryu, Sang-Ho;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.437-444
    • /
    • 2008
  • Purpose: A number of techniques and materials have been used for periodontal regeneration and bone graft procedures with guided tissue regeneration(GTR) have been suggested as alternatives to osseous surgery in the management of local infra-bony defects. However, the long-term stability and treatment outcome following bone graft procedure of infra-bony defects is poorly documented. The purpose of this study was to assess radiographic change in infra-bony defects over 2 years after bone graft procedures with various graft materials. Material and Methods: Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients showed clinical and radiographic evidence of infra-bony defect(s). 44 sites of 34 patients aged 31 to 69 (mean age 48.3) were treated by bone graft procedure with a bone graft material. Baseline and 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, defect depth, defect angle, bone graft materials) using the paired t-test were examined. Result: We observed $1.15{\pm}1.95\;mm$ of bone fill, $0.40{\pm}1.19\;mm$ of crestal resorption, $1.55{\pm}1.77\;mm$ of defect resolution, and $40{\pm}44%$ of percentage of defect resolution. Deeper initial defect depth, narrower initial defect angle showed significantly greater bone fill, defect resolution, and % of defect resolution. But no significant difference was observed in graft sites and graft materials. Conclusion: If good oral hygiene maintenance and periodic recall check of patients is assured, bone graft procedure using various graft materials is one of the appropriate treatment modality for regenerative therapy of infra-bony defects.

A study on surface fatigue crack behavior of SS400 weldment (SS400 용접부의 표면피로균열거동에 관한 연구)

  • 이용복;조남익;박강은
    • Journal of Welding and Joining
    • /
    • 제14권2호
    • /
    • pp.90-95
    • /
    • 1996
  • In order to investigate characteristics of surface fatigue crack propagation from a pit shaped surface defect which frequently exists around welded joints, SS400 steel with thickness of 12mm, which has been generally used for structure members, was welded with submerged-arc butt type and machined for both surface. An initial surface defect of pit shape with the aspect ratio of 2 was made on the specimen. The initial defect was located at 5 different zones over the weldment : weld metal zone, boundary between weld metal and HAZ, HAZ, boundary between HAZ and base metal. Characteristics of surface fatigue crack propagation from the defect on each region under the same loading condition were investigated and compared.

  • PDF

Prediction of defect shape change using multiple scale modeling during wire rod rolling process (멀티 스케일 모델을 적용한 선재 공정의 미세결함 형상 변화 예측)

  • Kwak, Eun-Jeong;Kang, Gyeong-Pil;Lee, Kyung-Hoon;Son, Il-Heon
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 2009년도 추계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 2009
  • Multiple scale modeling has been applied to predict defect shape change during the wire rod rolling process. The size difference between bloom and defect prevent using usual FEM approaches due to the enormous number of elements required to depict the defect. The newly developed multiple scale model can visualize defect shape changes during the multi stands rolling process. The defect positioned at the top and side of bloom are smoothed out but the one at the middle evolved as folding or remained as crack. This approach can be used for defect control with roll shape design and initial bloom shape.

  • PDF

A Study on Cause of Defects in NIL Molding Process using FEM (유한요소 해석을 이용한 나노임프린트 가압 공정에서 발생하는 결함 원인에 대한 연구)

  • Song, N.H.;Son, J.W.;Kim, D.E.;Oh, S.I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.364-367
    • /
    • 2007
  • In nano-imprint lithography (NIL) process, which has shown to be a good method to fabricate polymeric patterns, several kinds of pattern defects due to thermal effects during polymer flow and mold release operation have been reported. A typical defect in NIL process with high aspect ratio and low resist thickness pattern is a resist fracture during the mold release operation. It seems due to interfacial adhesion between polymer and mold. However, in the present investigation, FEM simulation of NIL molding process was carried out to predict the defects of the polymer pattern and to optimize the process by FEA. The embossing operation in NIL process was investigated in detail by FEM. From the analytical results, it was found that the lateral flow of polymer resin and the applied pressure in the embossing operation induce the weld line and the drastic lateral strain at the edge of pattern. It was also shown that the low polymer-thickness result in the delamination of polymer from the substrate. It seems that the above phenomena cause the defects of the final polymer pattern. To reduce the defect, it is important to check the initial resin thickness.

  • PDF

Axially-compressed behavior of CFRP strengthening steel short columns having defects

  • Omid Yousefi;Amin Shabani Ammari
    • Structural Engineering and Mechanics
    • /
    • 제91권1호
    • /
    • pp.49-61
    • /
    • 2024
  • In recent decades, the majority of studies have concentrated on the utilization of Steel Square Hollow Section (SHS) columns, with minimal attention given to reinforcing columns exhibiting inherent defects. This study addresses this gap by introducing initial vertical and horizontal defects at three distinct locations (top, middle, and bottom) and employing Carbon-FRP for reinforcement. The research investigates the dimensional and positional impacts of these defects on the axial behavior of SHS columns. A total of 29 samples, comprising 17 with defects, 11 strengthened, and 1 defect-free control, underwent examination. The study employed ABAQUS modeling and conducted experimental testing. Results revealed that defects located at different positions significantly diminished the load-bearing capacity and initial performance of the steel columns. Axial loading induced local buckling and lateral rupture, particularly at the defect side, in short columns. Notably, horizontal (across the column's width) and vertical (along the column's height) defects in the middle led to the most substantial reduction in strength and load-bearing capacity. The axial compressive failure increased with the length-to-width ratio of the defect. Moreover, the application of four carbon fiber layers to strengthen the steel columns resulted in increased Energy Dissipation and a delayed onset of local buckling in the face of axial ruptures.

The Effects of high Energy(1.5MeV) B+ ion Implantation and Initial Oxygen Concentration Upon Deep Level in CZ Silicon Wafer (고 에너지 (1.5 MeV) Boron 이온 주입과 초기 산소농도 조건이 깊은 준위에 미치는 영향에 관한 연구)

  • Song, Yeong-Min;Mun, Yeong-Hui;Kim, Jong-O
    • Korean Journal of Materials Research
    • /
    • 제11권1호
    • /
    • pp.55-60
    • /
    • 2001
  • The effect of high energy B ion implantation and initial oxygen concentration upon defect formation and gettering of metallic impurities in Czochralski silicon wafer has been studied by applying DLTS( Deep Level Transient Spectroscopy), SIMS(Secondary ton Mass Spectroscopy), BMD (Bulk Micro-Defect) analysis and TEM(Transmission Electron Microscopy). DLTS results show the signal of the deep levels not only in as-implanted samples but also in low and high temperature annealed samples. Vacancy-related deep levels in as- implanted samples were changed to metallic impurities-related deep levels with increase of annealing temperature. In the case of high temperature anneal, by showing the lower deep level concentration with increase of initial oxygen concentration, high initial oxygen concentration seems to be more effective compared with the lower initial oxygen one.

  • PDF

Long-term radiographic evaluation of GTR treatment in intrabony defect (골연하 결손부에서 조직유도재생술의 장기적 방사선학적 변화 관찰)

  • Choi, Mi-Hye;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.181-192
    • /
    • 2007
  • Periodontal surgery as part of the treatment of periodontal disease is mainly performed 1) to gain access to diseased areas for adequate cleaning; 2) to achieve pocket reduction or elimination; and 3) to restore the periodontal tissues lost through the disease; i.e., a new attachment formation of periodontal regeneration. To accomplish the latter, often referred to as the ultimate goal of periodontal therapy, a number of surgical procedures have been advocated throughout the years. Clinical studies have demonstrated that considerable gain of clinical attachment and bone can be achieved following guided tissue regeneration (GTR) therapy of intrabony defects. The aim of this study was to analyse the radiographic bone changes 2-year after GTR using a bone graft material and nonresorbable membrane. Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients had clinical and radiographic evidence of intrabony defect(s), 33 sites of 30 patients aged 32 to 56 (mean age 45.6) were treated by GTR with a bone graft material and nonresorbable membrane. Baseline and 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, defect depth, defect angle, bone graft materials) using the paired t-test were examined. We observed $2.86{\pm}1,87mm$ of bone fill, $065{\pm}0.79mm$ of crestal resorption, $3.49{\pm}2.11mm$ of defect resolution, and $44.42{\pm}19.51%$ of percentage of defect resolution. Mandible, deeper initial defect depth, narrower initial defect angle showed greater bone fill, defect resolution, and % of defect resolution. But no difference was observed between xenograft and allograft. Outcome of GTR as a therapy of intrabony defect was better than other therapy, but herein, good oral hygiene maintenance as a anti-infective treatment and periodic recall check of patients are essential.

Automatic Defect Detection from SEM Images of Wafers using Component Tree

  • Kim, Sunghyon;Oh, Il-seok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권1호
    • /
    • pp.86-93
    • /
    • 2017
  • In this paper, we propose a novel defect detection method using component tree representations of scanning electron microscopy (SEM) images. The component tree contains rich information about the topological structure of images such as the stiffness of intensity changes, area, and volume of the lobes. This information can be used effectively in detecting suspicious defect areas. A quasi-linear algorithm is available for constructing the component tree and computing these attributes. In this paper, we modify the original component tree algorithm to be suitable for our defect detection application. First, we exclude pixels that are near the ground level during the initial stage of component tree construction. Next, we detect significant lobes based on multiple attributes and edge information. Our experiments performed with actual SEM wafer images show promising results. For a $1000{\times}1000$ image, the proposed algorithm performed the whole process in 1.36 seconds.