• 제목/요약/키워드: infusion rate

검색결과 348건 처리시간 0.03초

국내 응급실에서의 골수강내 주입법 사용 현황 (Current Status of Intraosseous Infusion Technique Use at Emergency Departments in Korea)

  • 최상천;박현수;김재우
    • Journal of Trauma and Injury
    • /
    • 제20권1호
    • /
    • pp.6-11
    • /
    • 2007
  • Purpose: Gaining vascular access is difficult and time-consuming in critically ill children, so nowdays, in many countries, intraosseous vascular access is frequently used for rapid vascular access in critically ill children. Its pharmacokinetics is close to that of the peripheral intravenous route, but its infusion flow rate is faster. The purpose of this study was to determine how widely the intraosseous infusion technique was being used in Korean emergency departments. Methods: We telephoned forty-two (42) randomly selected university-affiliated hospitals. We asked physicians if they use the intraosseous infusion technique. Responders were emergency and pediatric residents and emergency faculty. If they responded that they were not using the intraosseous infusion technique, we asked the reason. Also, we asked about their experiences with the intraosseous infusion technique. Results: Forty-two (42) hospitals were enrolled in this study. No hospital used the intraosseous infusion technique on a regular basis. However, 8 hospitals used the intraosseous infusion technique occasionally. None of the responders had experience with the intraosseous infusion technique. Conclusion: The intraosseous infusion technique is currently underrepresented at emergency departments in Korea.

개에서 Propofol 점적투여율 변화가 심혈관계에 미치는 영향 (Cardiovascular Effects of Propofol Infused for Maintenance of Anesthesia in Dogs)

  • 권영삼;장광호;장환수;박현정;임재현;오태호;엄기동;장인호
    • 한국임상수의학회지
    • /
    • 제19권2호
    • /
    • pp.199-203
    • /
    • 2002
  • Cardiovascular effects of propofol, were assessed after premedication with xylazine(1.0 mUkg, IM) under oxygen supply(200 ml/kg/min) via a endotracheal tube. Twelve adult mixed-breed dogs were divided into four groups; 0.2(Group 1), 0.4(Group 2), 0.6(Group 3) and 0.8 mg/kg/min(Group 4) of propofol respectively. Arterial blood pressure and electrocardiogram were monitored with a physiograph after an arterial catheter was inserted into the femoral artery. pH, arterial carbon dioxide tension($PaCO_2$and arterial oxygen tension($PaO_2$) were evaluated with arterial blood collected through the inserted catheter. Diastolic arterial pressure, systolic arterial pressure and mean arterial pressure were decreased slightly in Group I IIand III, but decreased significantly in Group IV. They were increased rapidly after stopping propofol infusion in Group IV pH was maintained in normal range in Group I, II and m, but was decreased in proportion to time passing in Group IV. $PaCO_2$ was increased significantly only in Group IV but $PaO_2$ was maintained in normal range in all groups Although heart rate was recorded in normal range for 90 minutes, arythmia was noted after stopping propofol infusion in all groups. It was concluded that propofol depressed the cardiovascular system in proportion to infusion dosage, and 0.8 mg/kg/min of propofol infusion rate was not appropriated in canine anesthesia with xylazine premedication.

면양의 췌장 외분비 기능에 미치는 cholate 및 deoxycholate의 영향 (Effects of cholate and deoxycholate on pancreatic exocrine secretion in sheep)

  • 현해성;이정길;마사노리 이소노;세이유 카토
    • 대한수의학회지
    • /
    • 제37권4호
    • /
    • pp.745-754
    • /
    • 1997
  • This study was designed to investigate the effects of cholate and deoxycholate on pancreatic exocrine secretion in conscious sheep with external bile and pancreatic fistulae. Bile and pancreatic juices were collected for a basal period of 2 hours. The pancreatic juice was returned to the intestine. Bile salts were infused into the jugular vein or duodenum for 90 minutes at the rate of 0.7mg/kg/min. Cholate and deoxycholate significantly increased the flow rate, pH and bicarbonate concentration of bile juice, but decreased the flow rate of pancreatic juice. The effects induced by intraduodenal infusion of both bile salts were significantly greater than those by intravenous infusion. Protein concentration and amylase activity in pancreatic juice were also significantly decreased by both bile salts; the effects were greater when the bile salts were infused into the duodenum than into the vein. The inhibitory effects induced by deoxycholate infusion were significantly greater than those by cholate infusion. The plasma concentration of secretin was significantly increased by intravenous infusion of deoxycholate, but it was not effected by intraduodenal infusion of both bile salts. The results indicated that cholate and deoxycholate markedly increased the secretion of bile juice and decreased the pancreatic exocrine secretion, although these effects were variable depending on the chemical composition or infusion routes.

  • PDF

치과 환자에서의 $Perfusor^{\circledR}$ fm 자가통증조절기를 이용한 Propofol 자가진정조절법 (Propofol Patient-Controlled Sedation Using $Perfusor^{\circledR}$ fm (B. Braun, Germany) Infusion Pump in Dental Patients-Preliminary Study)

  • 박창주;염광원;김현정
    • 대한치과마취과학회지
    • /
    • 제2권2호
    • /
    • pp.97-100
    • /
    • 2002
  • Background: Patient-controlled sedation (PCS) has been blown for a safe and effective sedative method on the same pharmacological concepts of patient-controlled analgesia. Many different kinds of infusion devices have been used but they often have too long nominal infusion rate and lockout time. $Perfuser^{\circledR}$ fm (B. Braun, Germany) is a new PCA device with 999.9 ml/hr nominal infusion rate and minimum 1 min lockout time. In this study, the feasibility of propofol PCS using $Perfuser^{\circledR}$ fm was examined in order to provide a safe satisfactory sedation for dental patients. Methods: Eleven healthy patients presenting for oral surgery were studied. Propofol PCS was performed using $Perfuser^{\circledR}$ fm, which was set to deliver a bolus dose of 5 mg with 999.9 ml/hr nominal infusion rate and 1 min lockout time. Propofol loading dose was randomly assigned to a bolus dose ${\times}$ 0, 2, and 3 (initial bolus). Patients were told to press the bolus button as often as they needed to relieve discomfort. Results: Total infused dose of propofol was mean 1.8 mg/kg/hr and D (Delivery)/A (Attempt) ratio was mean 72.8%. All patients was awake and there were no clinically significant intraoperative side effects during the sedation. Almost all patients were very satisfied with this type of PCS. Conclusion: Propofol PCS using $Perfuser^{\circledR}$ fm infusion pump provided good conscious sedation for dental procedures.

  • PDF

Anti-Aging Effects of the Hanwoo Leg Bone, Foot and Tail Infusions (HLI, HFI and HTI) on Skin Fibroblast

  • Seol, Ja young;Yoon, Ji Young;Jeong, Hee Sun;Joo, Nami;Choi, Soon Young
    • 한국축산식품학회지
    • /
    • 제36권2호
    • /
    • pp.237-243
    • /
    • 2016
  • Many researchers revealed that collagen contribute to maintaining the skin’s elasticity and inhibit wrinkling of skin. Korean native cattle (Hanwoo) bone (leg bone, foot and tail) infusion contains the various inorganic materials, collagen and chondroitin sulfate. All of this, a large quantity of collagen is included in Hanwoo infusion. Therefore, this study emphasized on the effects of collagen in the Hanwoo bone infusion. For the first time, Hanwoo bone infusions were directly added to the media of Human Dermal Fibroblast (NHDF-c) to test anti-aging effects. First, it was identified that growth rate of skin fibroblast was increased. Furthermore, the Hanwoo bone infusion increased a 50% of fibroblast collagen synthesis. Also, suppression of skin fibroblast aging was confirmed by treatment Hanwoo bone infusion. In conclusion, this study demonstrates the effects of infusion made from Hanwoo leg bone, foot and tail on anti-aging, wrinkle inhibiting and skin fibroblast elasticity maintaining. Therefore, this study identified that traditional infusion has effects that are good for skin elasticity.

무마취 가토 신장기능에 미치는 Atrial Natriuretic Factor의 영향 (Effect of Atrial Natriuretic Factor on the Renal Function and Renin Release in Unanesthetized Rabbit)

  • 이준규;조경우
    • The Korean Journal of Physiology
    • /
    • 제20권1호
    • /
    • pp.103-124
    • /
    • 1986
  • Since it has been suggested that atrial receptor may be involved in the mechanism of extracellular volume regulation, it was shown that the granularity of atrial cardiocytes can be changed by water and salt depletion, and that an extract of cardiac atrial tissue, when injected intravenously into anesthetized rats, was shown to cause a large and rapid increase in renal excretion of sodium. Various natriuretic peptides were isolated and synthetized, and the effects were investigated by many workers. Most studies, however, have been carried out under anesthesia and there have teen some controversies over direct effect of the factor on the renal function. Therefore, it was attempted in this study to access the effects of an atrial extract and a synthetic natriuretic factor in unanesthetized rabbits. Intrarenal arterial infusion of atrial extract caused a rapid increase of urinary volume and excretion of sodium. Glomerular filtration rate and renal plasma flow were both increased with no change in filtration fraction. The ventricular extract produced no change in urinary excretion of electrolytes, nor in renal hemodynamics. Intrarenal infusion of synthetic atrial natriuretic factor caused increases of renal excretory rate of sodium, chloride and potassium, and $FE_{Na}$. Glomerular filtration rate, renal plasma flow increased. And free water clearance also increased. Accentuated excretory function correlated well with increased glomerular filtration rate and renal plasma flow during infusion and for 10 minutes following the cessation of the infusion. Renin secretion rate decreased during constant infusion of atrial natriuretic factor. However, no correlation was found with the changes in glomerular filtration rate, renal plasma flow, or urinary excretion of sodium. These results suggest that atrial extract or atrial natriuretic factor induces changes in renal hemodynamics, as in excretion of electrolytes either indirectly through hemodynamic changes or directly by inhibiting tubular reabsorption. At the same time, renin secretory function is affected by the factor possibly through an unknown mechanism.

  • PDF

소아 Whitaker 검사시에 적절한 관류속도는? (What is the Appropriate Infusion Rate during Whitaker Test in Children?)

  • 정기현;이경익
    • Childhood Kidney Diseases
    • /
    • 제2권2호
    • /
    • pp.178-182
    • /
    • 1998
  • 목 적 : 폐색성 요로질환의 진단방법 중 하나인 Whitaker 검사는,소아에서 신우내 관류액의 주입속도를 일반적으로 5mL/min로 시행한다. 그러나 이러한 속도는 생리적이지 못할 뿐 아니라 급속한 신우내 압력의 상승으로 요일출, 신내역류 등의 합병증을 초래할 수 있다. 이에 저자들은 소아 Whitaker 검사사, 보다 낮은 관류속도에서 어떠한 신우내 압력의 변화가 오는가를 관찰하고 적절한 관류속도를 평가하고자 하였다. 방 법 : 이뇨성 신주사로 요로폐색의 진단이 모호했던 3명의 편측 수신증 환아를 대상으로 Whitaker검사를 시행하였으며, 이때 신우내 관류속도를 1 mL/min로부터 시작하여 폐색의 진단기준인 신우내 압력이 $22\;cmH_2O$ 이상이 쥘 때까지 서서히 증가시켰다. 결 과 : 1례에서는 2 mL/min의 관류속도에서 신우내압력이 $50\;cmH_2O$까지 상승하였고 다른 2례에서도 3 mL/min에서 양성의 결과를 얻을 수 있었다. 한편 검사 중, 요일출 등의 부작용은 발생하지 않았다. 결 론 : 소아 Whitaker검사시 관류속도를 획일적으로 5mL/min로 시행하기보다는 1 mL/min로부터 서서히 속도를 증가시킴으로써 요로폐색의 진단을 내릴 수 있을뿐더러, 검사의 합병증을 예방할 수 있을 것으로 사료된다.

  • PDF

Significance of Hypovolemia in Feed Intake Control of Goats Fed on Dry Feed

  • Sunagawa, Katsunori;Prasetiyono, Bambang W.H.E.;Shinjo, Akihisa
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권9호
    • /
    • pp.1267-1271
    • /
    • 2001
  • The objective of this study was to examine the significance of feeding induced hypovolemia (decrease in plasma volume) in controlling the feed intake of goats fed on dry feed. In order to alleviate hypovolemia with feeding, a 2 h intravenous infusion (16-18 ml/min) of artificial saliva or mannitol solution was begun 1 h prior to feeding and continued until 1h after the start of the 2 h feeding period. In comparison with no infusion (NI), cumulative feed intake was increased by 41% with artificial saliva infusion (ASI) and by 45% with mannitol infusion (MI) by the completion of the 2 h feeding period. Both infusion treatments (ASI and MI) were significantly different (p<0.05) from the NI treatment in terms of the cumulative feed intake. The cumulative feed intake between the ASI and MI treatments was not significantly different (p>0.05). No infusion treatment (NI) had the lowest cumulative feed intake (929 g DM), whereas MI had the highest (1345 g DM), after completion of the 2 h feeding period. Generally, infusion treatments also increased the rate of eating at all time points after feeding was commenced. Following the first 30 mins of feeding, the rate of eating decreased sharply, and subsequently declined gradually in all treatments. Compared to the NI, both ASI and MI significantly (p<0.05) decreased thirst level (water intake for 30 mins after the completion of the 2 h feeding period) by approximately 13%. However, the thirst level caused by ASI and MI was not significantly different (p>0.05). Both ASI and MI decreased the plasma concentrations of osmolality and total protein, and hematocrit at 1 h after infusion. The results suggested that the thirst sensation in the brain could be produced by feeding induced hypovolemia. Moreover, the results indicate that hypovolemia is one of the factors controlling the feed intake of goats fed on dry feed.

냉혈 K 심정지액의 임상적 이용 (Clinical use of cold blood potassium cardioplegia)

  • 오봉석;김상형;이동준
    • Journal of Chest Surgery
    • /
    • 제15권1호
    • /
    • pp.35-39
    • /
    • 1982
  • Cold blood potassium cardioplegia, by two types of the infusion systems, was used in 45 patients who were undergone the open cardiac operation. Method A [in 25 patients] was the syringe infusion system and method B [in 20 patients] was the pump infusion system. Cold blood potassium cardioplegic solution was used less amount on method B than method A. Serum potassium was often increased significantly on method A as a result of excessive infusion of cold blood potassium cardioplegic solution. But method B, excessive infusion of cold blood potassium cardioplegic solution was prevented by reperfusion of the previous infused cold blood potassium cardioplegic solution through the recirculation system. Alteration of infused rate and concentration of potassium in cold blood potassium cardioplegic solution during infusion [which might be suggested on the method A] could be controlled on method B.

  • PDF

Efficacy evaluation of syringe pump developed for continuous drug infusion

  • Jung, Bongsu;Seo, Kwang-Suk;Kwon, Suk Jin;Lee, Kiyoung;Hong, Suyong;Seo, Hyounsoon;Kim, Gi-Young;Park, Geun-Mook;Jeong, Juhee;Seo, Soowon
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제16권4호
    • /
    • pp.303-307
    • /
    • 2016
  • Background: In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be received from the approving agency based on such test results. Methods: The authors of the present study developed a novel syringe pump and performed efficacy evaluation by testing its infusion speed at 1 and 25 ml/h, and infusion performance testing at 2 and 24 h. Moreover, performance evaluation was conducted by comparing the novel pump to an existing pump with the infusion speed varied from 1 to 5 ml/h. Results: In the efficacy testing on the newly developed syringe pump, infusion with the infusion speed initially set to 1 ml/h resulted in infusion speeds of 1.00 and 0.99 ml/h in the 2- and 24-h assessment, respectively. Changing the infusion speed setting to 25 ml/h resulted in an infusion speed of 25.09 and 23.92 ml/h in the 2- and 24-h assessment, respectively. These results show no significant differences when compared with other commercially available pumps. Conclusions: The efficacy testing of the newly developed syringe pump showed the accuracy to be within tolerance. Based on these findings, we believe that the newly developed syringe pump is suitable for clinical use.