• Title/Summary/Keyword: infrared thermal measurement

Search Result 140, Processing Time 0.044 seconds

A Review of the Domestic Study Trends on Obstetrics & Gynecological Diseases by Using Digital Infrared Thermal Imaging as a Diagnosis Instrument (한방여성의학 영역에서 진단 도구로 적외선 체열 검사(Digital Infrared Thermal Imaging, DITI)를 활용한 국내 연구 동향 분석)

  • Im, Ji-Yeong;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.3
    • /
    • pp.80-94
    • /
    • 2020
  • Objectives: The purpose of this review is to analyze the domestic study trends of clinical use of Digital Infrared Thermal Imaging (DITI) as a diagnosis instrument on obstetrics and gynecological diseases in Korean literature. Methods: We searched for clinical studies using DITI in the journal of Korean obstetrics & gynecology, National Digital Science Library, Research Information Sharing Service, Korean Medical Database up to May 2020. After searching studies, we selected studies and analyzed according to disease. Results: 18 clinical studies were published in two kinds of academic journals. There were 4 studies about dysmenorrhea and menopausal symptoms, 2 studies about postpartum disease and hypercryalgesia, 1 study about amenorrhea, premenstrual syndrome, leukorrhea, infertility, polycystic ovary syndrome and hot flush. Conception vessel was frequently used for DITI measurement, followed by stomach meridian. The temperatures of abdomen (CV4, CV12), face (HN3), upper and lower limb (PC8, LU4, LR3, ST32) were commonly measured. Conclusions: This study shows that DITI could be one of effective diagnosis instrument for obstetrics and gynecological diseases. More well-designed clinical studies using DITI will be needed.

Evaluation of the characteristics of the reflection plate to measure defects in the invisible area using infrared thermography

  • Kim, Sang Chae;Park, Il Cheol;Kang, Chan Geun;Jung, Hyunchul;Chung, Woon Kwan;Kim, Kyeong Suk
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.856-862
    • /
    • 2020
  • Defect inspection system for industrial applications takes the important portion. Non-destructive inspection method has been significantly improved. Infrared thermography, as one of method for non-destructive inspection, can provide relatively precise data and quick inspection time. This study, it was performed to measure defect according to the measurement limit of the non-visible areas such as the back surface of the pipe using reflection plate using reflection plate based on Infrared thermography. The materials of the reflection plate were determined in consideration of the space limitation and the thermal characteristics, and defects were detected by the manufactured reflection plate. Detection of defect in non-visible area using the candidate materials for reflection plate was conducted.

A Study on the quantitative measurement methods of MRTD and prediction of detection distance for Infrared surveillance equipments in military (군용 열영상장비 최소분해가능온도차의 정량적 측정 방법 및 탐지거리 예측에 관한 연구)

  • Jung, Yeong-Tak;Lim, Jae-Seong;Lee, Ji-Hyeok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.557-564
    • /
    • 2017
  • The purpose of the thermal imaging observation device mounted on the K's tank in the Republic of Korea military is to convert infrared rays into visual information to provide information about the environment under conditions of restricted visibility. Among the various performance indicators of thermal observation devices, such as the view, magnification, resolution, MTF, NETD, and Minimum Resolvable Temperature Difference (MRTD), the MRTD is the most important, because it can indicate both the spatial frequency and temperature resolvable. However, the standard method of measuring the MRTD in NATO contains many subjective factors. As the measurement result can vary depending on subjective factors such as the human eye, metal condition and measurement conditions, the MRTD obtained is not stable. In this study, these qualitative MRTD measurement systems are converted into quantitative indicators based on a gray scale using imaging processing. By converting the average of the gray scale differences of the black and white images into the MRTD, the mean values can be used to determine whether the performance requirements required by the defense specification are met. The (mean) value can also be used to discriminate between detection, recognition and identification and the detectable distance of the thermal equipment can be analyzed under various environmental conditions, such as altostratus, heavy rain and fog.

Thermal Design and Heat Load Measurement of PSICS (적외선 우주망원경 냉각시스템 열설계 및 열침입량 측정)

  • Yang H. S.;Kim D. L.;Lee B. S.;Choi Y. S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.43-46
    • /
    • 2005
  • A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cryocooler was designed. The PSICS has an IR sensor inside a cold box which is cooled by a stilting cryocooler with refrigeration capacity of 500mw at 80K in a vacuum vessel. It is important to minimize heat load for reducing background thermal noise. In order to design the cryogenic system of low heat load and to reduce heat load, we did several numerical analyses and tested using boil-off calorimetry with liquid nitrogen to measure the heat leak of the system. In this paper, we present the results obtained by thermal analysis and heat load measurement for designing the PSICS.

Thermal Analysis of Silicon Carbide Coating on a Nickel based Superalloy Substrate and Thickness Measurement of Top Layers by Lock-in Infrared Thermography

  • Ranjit, Shrestha;Kim, Wontae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.75-83
    • /
    • 2017
  • In this paper, we investigate the capacity of the lock-in infrared thermography technique for the evaluation of non-uniform top layers of a silicon carbide coating with a nickel based superalloy sample. The method utilized a multilayer heat transfer model to analyze the surface temperature response. The modelling of the sample was done in ANSYS. The sample consists of three layers, namely, the metal substrate, bond coat and top coat. A sinusoidal heating at different excitation frequencies was imposed upon the top layer of the sample according to the experimental procedures. The thermal response of the excited surface was recorded, and the phase angle image was computed by Fourier transform using the image processing software, MATLAB and Thermofit Pro. The correlation between the coating thickness and phase angle was established for each excitation frequency. The most appropriate excitation frequency was found to be 0.05 Hz. The method demonstrated potential in the evaluation of coating thickness and it was successfully applied to measure the non-uniform top layers ranging from 0.05 mm to 1 mm with an accuracy of 0.000002 mm to 0.045 mm.

Development of the Ultra Precision Thermal Imaging Optical System (초정밀 열 영상 현미경 광학계 개발)

  • Yang, Sun-Choel;Won, Jong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.15-21
    • /
    • 2010
  • Recently, there is a demand for a thermal imaging microscope in the medical field as well as the semi-conductor industry Although the demand of the advanced thermal imaging microscope has been increased, it is very difficult to obtain the technology of developing a thermal camera, because it is used for defense industry. We developed the ${\times}5$ zoom microscope which has $3\;{\mu}m$ spatial resolution to research the design and fabrication of the IR (Infrared) optical system. The optical system of the IR microscope consists of four spherical lenses and four aspheric lenses. We verified individual sensitivity of each optical parameter as the first order approach to the analysis. And we also performed structure and vibration analysis. The optical elements are fabricated using Freeform 700A. The measurement results of surface roughness and form accuracy using NT 2000 and UA3P are Ra 2.36 nm and P-V $0.13\;{\mu}m$. Finally we ascertained resolution power of $3\;{\mu}m$ using USAF (United State Air Force) 1951 IR resolution test chart.

The Change of Clothing Insulation and Surface Temperature Measured by Thermography with the Ease of Pattern (의복의 여유분에 따른 단열력의 변화와 Thermogram을 활용한 의복 표면 온도 특성 분석)

  • Lee, Byung-Cheol;Hong, Kyung-Hi;Lee, Ye-Jin
    • Korean Journal of Human Ecology
    • /
    • v.19 no.6
    • /
    • pp.1045-1052
    • /
    • 2010
  • Effects of the ease of pattern on the thermal conditions of clothing were investigated through the measurement of clothing surface temperatures using infrared thermography. Four vests with different pattern ease were worn by five male subjects. Surface temperature distribution on the clothing were then examined using a thermogram to view thermo-regulating characteristics affected by the ease of pattern. Representative surface temperatures were calculated based on the percentage of the surface area within a certain temperature range and the midpoint value of the corresponding area. Representative surface temperatures matches well to the thermal insulation value measured by thermal manikin. Results indicated that representative surface temperature could be a useful quantitative value if some simple calculations were to be used alongside accurate image processing.

Comparisons of Measurement Methods of the Moisture Content of Dried Vegetables (건조채소(乾燥菜蔬)의 수분측정방법(水分測定方法) 비교(比較))

  • Kwon, C.S.;Lee, D.S.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.1
    • /
    • pp.39-44
    • /
    • 1987
  • Measurement methods of moisture content were compared with 7 dried vegetables (red pepper, onion, green onion, garlic, ginger, carrot and radish). The moisture contents of dried vegetables having different moisture contents were determined by atmospheric oven drying, infrared balance, vacuum oven and Karl Fisher methods. Vacuum oven and Karl Fisher methods gave the relatively agreed results and considered to give the accurate moisture content. Atmospheric oven drying and infrared balance methods resulted in higher moisture content than methods mentioned above, because of the thermal decomposition of solid. Calibration of the moisture data of atmospheric oven drying method into the vacuum oven data was undertaken. The thermodecomposable solid fraction was high in onion, radish, green onion and carrot, and was in the range of 8.0-11.7% of the total solid in these products.

  • PDF

Distance Measurement of Small Moving Object using Infrared Stereo Camera (적외선 스테레오 카메라를 이용한 소형 이동체의 거리 측정)

  • Oh, Jun-Ho;Lee, Sang-Hwa;Lee, Boo-Hwan;Park, Jong-Il
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • This paper proposes a real-time distance measurement system of high temperature and high speed target using infrared stereo camera. We construct an infrared stereo camera system that measure the difference between target and background temperatures for automatic target measurement. First, the proposed method detects target region based on target motion and intensity variation of local region using difference between target and background temperatures. Second, stereo matching by left and right target information is used to estimate disparity about real-time distance of target. In the proposed method using infrared stereo camera system, we compare distances in three dimension trajectory measuring instrument and in infrared stereo camera measurement. In this experiment from three video data, the result shows an average 9.68% distance error rate. The proposed method is suitable for distance and position measurement of varied targets using infrared stereo system.

STS Defect Structure Diagonis through the Infrared Thermography Mechanism and Flex-PDE Thermal Analysis (적외선 열화상 메카니즘과 Flex-PDE 열해석을 통한 STS 결함구조물 진단)

  • Park, Young Hoon;Yang, Sung Mo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.20-29
    • /
    • 2014
  • This research aims to study the new paradigm of NDE measurement which allows the identification of defect locations and sizes of a certain structure by measuring its surface temperature after applying heat. STS which has a certain defect is applied by the heat of 70000W by a heater. Its difference of STS surface temperature is measured by using Infrared thermography. The estimated result of STS experiment and that of theoretical analysis of Flex-PDE are compared and analyzed to diagnose STS defect. Moreover, this study can save time and money and improve accuracy in contrast to the existing ultrasonic NDE experiment. In addition, the new paradigm of NDT/NDE by reverse-engineering will be valid if the data of thermal analysis and temperature distribution from the specifications of many materials is accumulated and verified.