• Title/Summary/Keyword: infrared rays

Search Result 178, Processing Time 0.023 seconds

A Basic Study on Temperature Characteristic Analysis of Kumdo Motion by Infrared Rays Camera (열화상 카메라를 이용한 검도 동작의 온도 특성 분석 기초 연구)

  • Lee, Gyuseon;Nam, Joong Woong;Seok, Kang Hoon;Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.1
    • /
    • pp.18-23
    • /
    • 2012
  • The purpose of this study is to visually confirm on variation of temperature changes according to the basic of Kumdo by using infrared rays camera and to obtain the difference of temperature distribution according to the warm up procedure. We selected randomly two Kumdo players, and recorded twice continuously their actions of three basic(Head Hitting, Wrist Hitting, Waist Hitting) motions of Kumdo. In other to obtain the effect of warm up procedure, we recorded again their actions including warm-up motions. Four measuring points on the body were selected in each motion considering the error on continuous recoding. Temperature distributions of the before and after warming up procedure were analyzed at two measuring point. Skin temperature distributions of the players's body in two cases are shown a similar tendency. It can be predicted that the parts of large physical movement result in the large changes of temperature according to the warm up motion.

  • PDF

A Basic Study on Temperature Characteristic Analysis of Taekgyeon Motion by Infrared Rays Camera (열화상 카메라를 이용한 택견 동작의 온도 특성 분석 기초 연구)

  • Lee, Gyuseon;Nam, Joong Woong;Seok, Kang Hoon;Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • The purpose of this study is to visually confirm on variation of temperature changes according to the basic of Taekgyoen by using infrared rays camera and to obtain difference of temperature distribution according to the warm up procedure. We selected randomly two Taekgyeon players, and recorded twice continuously their actions of three basic motions of Taekgyeon. In other to obtain effect of warm up procedure, we recorded again their actions including warm-up motions. Four measuring points on the body were selected in each motion considering the error on continuous recoding. Temperature distributions of the before and after warming up procedure were analyzed at two measuring point. Temperature distributions of skin of players body in two cases are shown a similar tendency. It can be predicted that the parts of large physical movement result in the large changes of temperature according to the warm up motion.

  • PDF

Study on bubble detection sensor for safe sap and blood injection

  • Yun, Young Gi;Lee, Hoo Young;Park, Koo Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.149-154
    • /
    • 2017
  • The infusion of fluid and blood is necessary in the ward, operating room, recovery room, neonatal room, etc. for nutrition and blood supply to the patient, but air bubbles generated during infusion of fluid and blood circulate along the artery or vein. Serious illnesses occur and there is also a risk of death. In this paper, we propose a medical bubble detection system, a bubble detection system, a bubble detection alarm system, and a communication method in order to develop a safer fluid and blood injection system in the existing system, which is detected by a medical staff monitoring system or an ultrasonic bubble detection sensor In this study, infrared rays are transmitted to a tube through a tube for injecting fluid or blood into a patient, infrared rays transmitted by an infrared ray emitting section are received, and the amount of light is measured in real time. Based on the data, we study how to detect and analyze the presence of bubbles in fluid and blood.

An Object Recognition Performance Improvement of Automatic Door using Ultrasonic Sensor (초음파 센서를 이용한 자동문의 물체인식 성능개선)

  • Kim, Gi-Doo;Won, Seo-Yeon;Kim, Hie-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.97-107
    • /
    • 2017
  • In the field of automatic door, the infrared rays and microwave sensor are much used as the important components in charge of the motor's operation control of open and close through the incoming signal of object recognition. In case of existing system that the sensor of the infrared rays and microwave are applied to the automatic door, there are many malfunctions by the infrared rays and visible rays of the sun. Because the automatic doors are usually installed outside of building in state of exposure. The environmental change by temperature difference occurs the noise of object recognition detection signal. With this problem, the hardware fault that the detection sensor is unable to follow the object moving rapidly within detection area makes the sensing blind spot. This fault should be improved as soon as possible. Because It influences safety of passengers who use the automatic doors. This paper conducted an experiment to improve the detection area by installing extra ultrasonic sensor besides existing detection sensor. So, this paper realize the computing circuit and detection algorithm which can correctly and rapidly process the access route of objects moving fast and the location area of fixed obstacles by applying detection and advantages of ultrasonic signal to the automatic doors. With this, It is proved that the automatic door applying ultrasonic sensor is improved detection area of blind spot sensing through field test and improvement plan is proposed.

Wound Recovery of Light Irradiation by White LED (백색 LED 조사의 상처 수복 효과)

  • Cheon, Min-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.42-46
    • /
    • 2011
  • Light can be divided into ultraviolet rays, visible rays, and infrared rays depending on the wavelengths. Visible rays with specific wavelength are those predominantly used for would treatment. Especially low level laser irradiates into cells, effectively stimulating cellular tissues and activating cellular function. This study was intended to verify the effect of white LED irradiation therapy on wound recovery in animal tests by applying white LED irradiator, which was independently designed and developed to emit beams of similar wavelength to that of a laser. The designed LED Irradiator was used to find out how white LED light source affected the skin wound of SD-Rat(Sprague-Dawley Rat). We divided the participants into two groups; white LED irradiation group which was irradiated 1 hour a day for 9 consecutive days, and none irradiation group. The results showed that the study group had lower incidence of inflammation and faster recovery, compared with the control group.

Effect of 41℃ deep heat formed by vacuum heating on various pain: Dr.Pakk (Dr. 팍) for pain care

  • Chang, Tae-soun
    • CELLMED
    • /
    • v.12 no.4
    • /
    • pp.16.1-16.2
    • /
    • 2022
  • Treatment of patients with pain is directed at relieving pain and restoring function. Heat therapy has been used as a pain treatment. The mean temperatures were 40 and 41℃. Our device, Dr.Pakk heats special silicone to 41℃ with far-infrared rays and attaches it to the painful knee using a vacuum to show the effect. The core technology of the Dr.Pakk is that deep heat is generated when the heat is transmitted deeply by attaching it to the skin. In our experience, Dr.Pakk can be especially effective for knee pain.

Thermo-Analysis of Machining Center Main-Axis Thermo-Displacement for Infrared Rays Thermo-Image Camera (적외선 열화상 카메라를 이용한 머시닝 센터 주축 열변위에 관한 열해석)

  • Kim, Jae-Yeol;Yoon, Sung-Un;Yim, Noh-Bin;Yu, Sin;Ma, Sang-Dong;Yang, Dong-Jo;Song, In-Suk
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.125-130
    • /
    • 2001
  • Diagnosis or measurements using Infrared thermo-image hasn t been available. A quick diagnosis and thermal analysis can be possible when that kind of system is introduced to the investigation of each part. In this study, Infrared Camera, Thermo-vision 900 was used in order to investigate. Infrared Camera usually detects only Infrared wave from the light in order to illustrate the temperature distribution. Infrared diagnosis system can be applied to various field. Also, it is more effective to analyze temperature distribution on the machining center main-axis process.

  • PDF

KARI infrared observations of the Crab Nebula

  • Im, Soo-Jin;Koo, Bon-Chul;Lee, Jae-Joon;Lee, Ho-Gyu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.70.2-70.2
    • /
    • 2010
  • We present near- and mid-infrared images of the Crab Nebula, taken with the Infrared Camera (IRC) onboard the AKARI infrared space telescope. These images have a field-of-view of 10'*10' and show the full extent of the nebula at 3, 4, 7, 11, 15, and 24 um. The Crab nebula in near infrared is dominated by synchrotron emission while, in mid infrared, the ionic forbidden lines of Ar, Ne, S, and Fe makes significant contribution. We separate the line emission from synchrotron emission in 3-15 um AKARI bands using the ISOCAM CVF data, and present separate images for the line and synchrotron emissions in each band. We derive the total synchrotron fluxes of the Crab nebula in these bands, which are used to complete the synchrotron spectral energy distribution of the Crab nebula from radio to X-rays. We discuss the spectral variations of the Crab nebula.

  • PDF

APPLICATION OF INFRARED THERMOGRAPHY IN DENTISTRY (치과에서의 적외선 체열사진의 응용)

  • Lee, Hoon;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.4
    • /
    • pp.335-341
    • /
    • 2005
  • This study discusses the effects of infrared thermography in dentistry. Infrared thermography allows the quantification of infrared rays and provides useful data for dental care and research. It has been used for the diagnosis of temporomandibular dysfunction (TMD) and proposed as an objective measure of myofascial pain. It is closely related to temperature and produces beneficial objective data. A study of the heat emissions from facial structures has the potential to benefit dental diagnosis of TMD, postoperative inferior alveolar damage, and endodontic and conservative treatments. In this paper, we assessed infrared thermography in dentistry and consider future developments of infrared thermography.

Study on the Development of Steam Boiler using Carbon-fiber Heater (탄소섬유 발열체를 이용한 증기 보일러 개발에 관한 연구)

  • Kim, Bu-Ahn;Kang, Suk-Jun;Choi, Young-Min;Moon, Chang-Kown
    • Journal of Power System Engineering
    • /
    • v.21 no.3
    • /
    • pp.30-36
    • /
    • 2017
  • Carbon fiber shows excellent heat generation value and thermal efficiency comparing with the metallic materials because of its far infrared-rays and radiant heat. So, high performance and economic steam boiler system for the industry can be manufactured by using the carbon fiber heater. The far infrared ray radiation rate was more than 90 % of carbon fiber. Steam boiler system with carbon fiber heater in this study is made up of heating section. In the proof test of steam boiler, the aimed temperature and dwelling time were at $500^{\circ}C$ for 8,000 hours, $600^{\circ}C$-3,000 hours, and $700^{\circ}C$-1,000 hours. The temperature rise rate of steam boiler with carbon fiber heater was about 40% faster than that of the conventional boiler.